Ramanspektroskopi – avancerad optisk analysteknik
Förbättra anläggningssäkerheten, säkerställ produktkvaliteten och optimera driften. Ramanspektroskopi mäter sammansättningen och molekylstrukturen i dina prover från labb till process i realtid.
Den här produkten är inte tillgänglig i denna region.
Kontakta din Endress+Hauser-säljpartner för ytterligare frågor.
532 nm
150-3425 cm-1 (532 nm)
The Raman Rxn5 process analyzer is an industry-leading, turn-key, laser-based analyzer powered by Kaiser Raman technology. It provides quantitative chemical composition measurements using Raman spectroscopy. The design of the Raman Rxn5 incorporates customer requirements for serviceability and hazard-area certification, provides a compact footprint, and minimizes utilities consumption. The high optical efficiency of the analyzer makes it ideal for typical gas-phase sample measurements.
Process measurement points:
Steam methane reformers
Gasifiers (coal, petcoke, waste, biomass)
Shift converters
Hydrotreaters
Hydrocrackers
CO2 removal
Finished product synthesis loops
Typical industries:
Hydrogen production/purity, HyCO, Hydrogen recycle,
Methanol production
Ammonia production
Gas turbine fuel feed
Synthetic natural gas/IGCC power plants
Non-destructive analysis of gases, including homonuclear diatomics (H2, N2, O2)
Compact, smaller than most wall-mount gas chromatographs (GCs)
Can replace up to four traditional analyzers with a single base unit and four probes
Rugged with minimal utility requirements, no sample transport, and no consumables (columns, valves, gases, pumps)
Minimal analyzer technician time with maximum technician safety (no toxic gases are transported to the analyzer)
Measures four streams simultaneously for faster multi-channel results
-20 to +50 °C operating environment
High-end produkter
Tekniska egenskaper
Enkelhet
Standardprodukter
Tekniska egenskaper
Enkelhet
Specialprodukter
Tekniska egenskaper
Enkelhet
Varierande
| FLEX urvalet | Tekniska egenskaper | Enkelhet |
|---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
System design and specifications for the Raman Rxn5 analyzer -
powered by Kaiser Raman technology
| EN | SV | ||
|
11/11/2025
|
|
|
|
|
21/10/2025
|
|
|
|
|
27/02/2025
|
|
|
|
|
21/11/2023
|
|
|
|
|
31/12/2020
|
|
|
|
Språk: |
Engelska |
|
Version: |
11/11/2025 |
|
Filstorlek: |
3 MB |
|
Filnamn: |
TI01646CEN_0525.pdf |
Commissioning, operation, and maintenance details
for Raman RunTime v6.6 software
| EN | SV | ||
|
27/03/2025
|
|
|
|
|
16/11/2023
|
|
|
|
|
16/11/2022
|
|
|
|
|
30/06/2022
|
|
|
|
|
31/12/2020
|
|
|
|
Språk: |
Engelska |
|
Version: |
27/03/2025 |
|
Filstorlek: |
6.8 MB |
|
Filnamn: |
BA02180CEN_0525.pdf |
Commissioning, operation, and maintenance details for the
Raman Rxn5 analyzer - powered by Kaiser Raman technology
| EN | SV | ||
|
29/10/2025
|
|
|
|
|
17/03/2025
|
|
|
|
|
16/01/2025
|
|
|
|
|
21/11/2023
|
|
|
|
|
01/08/2023
|
|
|
|
Språk: |
Engelska |
|
Version: |
29/10/2025 |
|
Filstorlek: |
4.6 MB |
|
Filnamn: |
BA02179CEN_0625.pdf |
Quick start guide for the Raman Rxn5 analyzer -
powered by Kaiser Raman technology
| EN | SV | ||
|
13/03/2025
|
|
|
|
|
16/01/2025
|
|
|
|
|
21/11/2023
|
|
|
|
|
31/12/2020
|
|
|
|
Språk: |
Engelska |
|
Version: |
13/03/2025 |
|
Filstorlek: |
2.1 MB |
|
Filnamn: |
KA01554CEN_0425.pdf |
Instructions for use of the LNG analyzer performance verification kit
| EN | SV | ||
|
30/03/2023
|
|
|
|
Språk: |
Engelska |
|
Version: |
30/03/2023 |
|
Filstorlek: |
442.7 KB |
|
Filnamn: |
EA01470CEN_0123.pdf |
Hazardous area certifications and installation instructions
for the Raman Rxn5 analyzer - powered by Kaiser Raman technology
| EN | SV | ||
|
27/02/2025
|
|
|
|
|
13/01/2025
|
|
|
|
|
07/12/2023
|
|
|
|
|
31/12/2020
|
|
|
|
Språk: |
Engelska |
|
Version: |
27/02/2025 |
|
Filstorlek: |
1.7 MB |
|
Filnamn: |
XA02746CEN_0425.pdf |
An overview of the optical service kit for the Raman Rxn5 analyzer
containing tools and accessories with instructions on how to clean
and maintain the instrument to achieve its optimal performance.
|
Språk: |
Engelska |
|
Version: |
04/05/2022 |
|
Filstorlek: |
1 MB |
|
Filnamn: |
PU01467CEN_0122.pdf |
This paper presents experimental findings that validate the performance
of an Endress+Hauser Raman spectroscopic analyzer in accurately
measuring parahydrogen conversion during the hydrogen liquefaction
process.
|
Språk: |
Engelska |
|
Version: |
13/01/2026 |
|
Filstorlek: |
410.6 KB |
|
Filnamn: |
PU01623CEN_0126.pdf |
An overview of energy transition and the importance of gas analysis
via TDLAS, QF, and Raman spectroscopy (including the J22, JT33, OXY5500,
Raman Rxn4, and Raman Rxn5 analyzers) to meet the demand for an
energy supply chain shift away from carbon toward renewable energy,
natural gas, hydrogen, LNG, biogas and more in the oil & gas industry.
|
Språk: |
Engelska |
|
Version: |
14/05/2024 |
|
Filstorlek: |
2.3 MB |
|
Filnamn: |
PU01458CEN_0224.pdf |
A list of industry gas quality standards that our Raman Rxn5 analyzer
meets for gases and our Raman Rxn4 analyzer meets for LNG.
|
Språk: |
Engelska |
|
Version: |
08/01/2025 |
|
Filstorlek: |
432.3 KB |
|
Filnamn: |
PU01463CEN_0225.pdf |