En överblick över specifikationer
-
Measured variables
NO, NO2, NH3, SO2
-
Process temperature
≤ +550 °C
-
Ambient temperature range
–20 °C ... +55 °C
Temperature change maximum ±10 °C/h -
Hazardous area approvals
IECEx: Ex pzc op is [ia] IIC T3 Gc
ATEX: II 3G Ex pzc op is [ia] IIC T3 Gc
Applikationsområde
The GM32 in-situ gas analyzer measures SO2, NO, NO2 and NH3, pressure and temperature in the gas duct. Direct, fast and without gas sampling and transport. Due to self-monitoring, the measured values are reliable. In case of a malfunction, an early warning will be shown. For emission measurement of SO2 and NO, the GM32 is tested for suitability according to European standard EN 15267. An Ex-type with extensive safety functions and sophisticated system technology is also available.
For monitoring and control in flue gas purification, such as denitrification plants, desulfurization plants and converters
Emissions monitoring according to EU directives or local regulations
Device properties:
No gas sampling, no gas transport, no gas conditioning
Up to four measurands at the same time, plus process temperature and pressures
Numerous independent measuring ranges with consistent accuracy
Automated self-test function (QAL3) without test gases
Overpressure encapsulated type Ex-zone 2
Fördelar
Nearly uncompromised measured values measured directly in the gas duct
Short-term process deviations can be measured
Representative measurement by selection of cross-duct or measuring probe type
Fast on-site service possible due to modular design
Long maintenance-free intervals
Cost-effective in-situ gas analyzer — Ex-type also available
Low cost of installation and operation, no test gases required
Extended urvalet
-
High-end produkter
- Mycket funktionella och praktiska
Tekniska egenskaper
Enkelhet
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
| FLEX urvalet | Tekniska egenskaper | Enkelhet |
|---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
-
-
Teknisk information (TI)
GM32, measuring probe (TI)
In-situ Gas Analyzer, Measuring Probe Version
EN SV 01/01/2025Språk:
Engelska
Version:
01/01/2025
Filstorlek:
6.8 MB
Filnamn:
8030993_AE00_TI_GM32_Probe_en_V1-4_2013-11_EHS.pdf
-
-
-
Användarinstruktion (BA)
GMK03 - Gas Test Unit
The GMK03 gas test unit is used to test the linearity of the
measurement results of gas analyzers as required for a
metrological quality test (e.g. for QAL2, QAL3). For this purpose,
the GMK03 gas test unit can simulate several graded test gas
concentrations with a single (suitable) test gas.EN SV 01/05/2025Språk:
Engelska
Version:
01/05/2025
Filstorlek:
4.5 MB
Filnamn:
8031018_AE00_OI_GMK03_en_V3-0_2025-05_EHS.pdf
-
-
-
Användarinstruktion (BA)
GM32 Cross-Duct
In-situ Gas Analyzer, Cross-Duct Version
EN SV 01/01/2025Språk:
Engelska
Version:
01/01/2025
Filstorlek:
3.9 MB
Filnamn:
8029940_ZVF9_OI_GM32_CrossDuct_en_V2-1_2019-04_EHS.pdf
-
-
-
Användarinstruktion (BA)
GM32 Measuring Probe
In-situ-Gasanalysator Utförande mätsond
EN SV 01/01/2025Språk:
Svenska
Version:
01/01/2025
Filstorlek:
4.1 MB
Filnamn:
8030315_ZVS1_OI_GM32_Probe_sv_V2-1_2019-04_EHS.pdf
-
-
-
Användarinstruktion (BA)
GM32 Ex Cross-Duct
In-situ Gas Analyzer, Cross Duct Version
EN SV 01/01/2025Språk:
Engelska
Version:
01/01/2025
Filstorlek:
7.9 MB
Filnamn:
8029936_AE00_OI_GM32_Ex_3G_CrossDuct_en_V1-8_2017-08_EHS.pdf
-
-
-
Användarinstruktion (BA)
GM32 Ex Measuring Probe
In-situ Gas Analyzer, Measuring Probe Version
EN SV 01/01/2025Språk:
Engelska
Version:
01/01/2025
Filstorlek:
6.5 MB
Filnamn:
8029934_AE00_OI_GM32_Ex_3G_Probe_en_V1-9_2024-08_EHS.pdf
-
-
-
Kortfattad instruktion (KA)
Instrument Air Adapter for in-situ gas analyzers
Description of installation, commissioning and
maintenanceEN SV 01/01/2025Språk:
Engelska
Version:
01/01/2025
Filstorlek:
969.6 KB
Filnamn:
8029821_AE00_KA_Instrument_Air_Adapter_en_V1-0_2024-05_EHS.pdf
-
-
-
Ex-säkerhetsinstruktion (XA)
Safety Information
for non-Ex analyzer devices
(multi-lingual, also in DE, BG, CS, DA, EL, ES, ET, FI, FR, HR, HU, IT,
LT, LV, NL, NO, PL, PT, RO, RU, SK, SL, SV)Språk:
Engelska
Version:
01/01/2025
Filstorlek:
2.4 MB
Filnamn:
8030257_XA_Safety_Information_non-Ex_ml_V1-0_2016-06_WEB.pdf
-
-
-
Ex-säkerhetsinstruktion (XA)
GM32 Ex safety information
Safety Information for Ex Devices
(multi-lingual, also in DE, BG, CS, DA, EL, ES, ET, FI, FR, HR, HU, IT,
LT, LV, NL, NO, PL, PT, RO, RU, SK, SL, SV)Språk:
Engelska
Version:
01/01/2025
Filstorlek:
1.9 MB
Filnamn:
8030259_AE00_XA_GM32_Ex_V2-0_ml_2017-07_EHS_WEB.pdf
-
-
-
Specialdokumentation (SD)
GM32 Ex tightening torques
Tightening torques for GM32 Ex, Cross-Duct Version and Probe Version
Språk:
Engelska
Version:
01/01/2025
Filstorlek:
2 MB
Filnamn: