En överblick över specifikationer
-
Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 4100 t/h (0 to 4520 tn. sh./h)
-
Medium temperature range
–50 to +180 °C (–58 to +356 °F)
-
Max. process pressure
PN 100, Class 600
-
Wetted materials
Measuring tube: 1.4404 (316/316L)
Connection: 1.4404 (316/316L)
Applikationsområde
The patented four-tube Promass X provides premium accuracy (0.05 %) for highest capacity and offers an outstanding performance in on- and offshore applications in the oil and gas industry. With is innovative remote transmitter Promass X 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and compliant verification.
Measuring principle operates independently of physical fluid properties such as viscosity or density
For highest flow rates and outstanding performance in on/offshore applications in the oil and gas industry
Device properties
Nominal diameter: DN 300 to 400 (12 to 16")
Four-tube system with low pressure drop
Complete exterior design made of 1.4435 (316L)
Remote version with up to 4 I/Os
Backlit display with touch control and WLAN access
Standard cable between sensor and transmitter
Fördelar
-
Increased profit – single installation point providing premium accuracy for large quantities
-
Fewer process measuring points – multivariable measurement (flow, density, temperature)
-
Space-saving installation – no in-/outlet run needs
-
Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
-
Reduced complexity and variety – freely configurable I/O functionality
-
Integrated verification – Heartbeat Technology
Videor
-
Heartbeat Technology simply explained (3'14")
-
The Coriolis Flow Measuring Principle
Xpert urvalet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
| FLEX urvalet | Tekniska egenskaper | Enkelhet |
|---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
Föregångare
-
Mätprincip
Coriolis
-
Product headline
Highest capacity four-tube flowmeter, as remote version with up to 4 I/Os.
For highest flow rates and outstanding performance in on/offshore oil and gas applications. -
Sensor features
Increased profit – single installation point providing premium accuracy for large quantities. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Nominal diameter: DN 300 to 400 (12 to 16"). Four-tube system with low pressure drop. Complete exterior design made of 1.4435 (316L). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
DN 300 to 400 (12 to 16")
-
Wetted materials
Measuring tube: 1.4404 (316/316L)
Connection: 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 4100 t/h (0 to 4520 tn. sh./h)
-
Max. process pressure
PN 100, Class 600
-
Medium temperature range
–50 to +180 °C (–58 to +356 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –60 to +60 °C (–76 to +140 °F) -
Sensor housing material
1.4404 (316L), highest corrosion resistance
Sensor connection housing (standard): 1.4409 (CF3M), similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 Liquids other than water (Hydrocarbons), LPG, cryogenic
MI-002, PTB -
Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval, CCS approval
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
-
Mätprincip
Coriolis
-
Product headline
Highest capacity four-tube flowmeter, as remote version with up to 4 I/Os.
For highest flow rates and outstanding performance in on/offshore oil and gas applications. -
Sensor features
Increased profit – single installation point providing premium accuracy for large quantities. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Nominal diameter: DN 300 to 400 (12 to 16"). Four-tube system with low pressure drop. Complete exterior design made of 1.4435 (316L). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
DN 300 to 400 (12 to 16")
-
Wetted materials
Measuring tube: 1.4404 (316/316L)
Connection: 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 4100 t/h (0 to 4520 tn. sh./h)
-
Max. process pressure
PN 100, Class 600
-
Medium temperature range
–50 to +180 °C (–58 to +356 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –60 to +60 °C (–76 to +140 °F) -
Sensor housing material
1.4404 (316L), highest corrosion resistance
Sensor connection housing (standard): 1.4409 (CF3M), similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure" -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 Liquids other than water (Hydrocarbons), LPG, cryogenic
MI-002, PTB -
Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval, CCS approval
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK"
-
Mätprincip
Coriolis
-
Product headline
Highest capacity four-tube flowmeter, as remote version with up to 4 I/Os.
For highest flow rates and outstanding performance in on/offshore oil and gas applications. -
Sensor features
Increased profit – single installation point providing premium accuracy for large quantities. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Nominal diameter: DN 300 to 400 (12 to 16"). Four-tube system with low pressure drop. Complete exterior design made of 1.4435 (316L). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
DN 300 to 400 (12 to 16")
-
Wetted materials
Measuring tube: 1.4404 (316/316L)
Connection: 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 4100 t/h (0 to 4520 tn. sh./h)
-
Max. process pressure
PN 100, Class 600
-
Medium temperature range
–50 to +180 °C (–58 to +356 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –60 to +60 °C (–76 to +140 °F) -
Sensor housing material
1.4404 (316L), highest corrosion resistance
Sensor connection housing (standard): 1.4409 (CF3M), similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 Liquids other than water (Hydrocarbons), LPG, cryogenic
MI-002, PTB -
Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval, CCS approval
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
-
-
Teknisk information (TI)
TI Proline Promass X 500
-
Teknisk information (TI)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
EN SV 01/12/202511/11/202501/11/202429/03/202401/08/2022Språk:
Engelska
Version:
01/12/2025
Filstorlek:
9.3 MB
Filnamn:
TI01289DEN_1125-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass X 500 PROFINET
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
EN SV 01/12/202501/11/202416/09/201915/07/201902/10/2017Språk:
Engelska
Version:
01/12/2025
Filstorlek:
10.4 MB
Filnamn:
BA01768DEN_0525-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass X 500
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
HARTEN SV 01/12/202501/11/202401/08/202201/09/201902/10/2017Språk:
Engelska
Version:
01/12/2025
Filstorlek:
9.5 MB
Filnamn:
BA01536DEN_0625-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass X 500
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
Modbus RS485EN SV 01/12/202501/11/202401/08/202201/09/201901/12/2018Språk:
Engelska
Version:
01/12/2025
Filstorlek:
8.6 MB
Filnamn:
BA01547DEN_0725-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass X 500 FOUNDATION fieldbus
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
EN SV 01/12/202501/11/202401/11/2016Språk:
Engelska
Version:
01/12/2025
Filstorlek:
8.6 MB
Filnamn:
BA01569DEN_0325-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass X 500
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
PROFINET over Ethernet-APLEN SV 01/12/202501/11/202408/01/2024Språk:
Engelska
Version:
01/12/2025
Filstorlek:
9.6 MB
Filnamn:
BA02131DEN_0325-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass X 500 Ethernet/IP
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
EN SV 01/12/202501/11/202402/10/2017Språk:
Engelska
Version:
01/12/2025
Filstorlek:
9.5 MB
Filnamn:
BA01757DEN_0325-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass X 500 PROFIBUS PA
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
EN SV 01/12/202501/11/202401/11/201801/08/2016Språk:
Engelska
Version:
01/12/2025
Filstorlek:
8.8 MB
Filnamn:
BA01558DEN_0425-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass X 500
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
Modbus TCPEN SV 15/12/202511/11/2025Språk:
Engelska
Version:
15/12/2025
Filstorlek:
8.4 MB
Filnamn:
BA02423DEN_0225-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass X 500 PROFIBUS DP
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
EN SV 01/12/202501/11/202401/06/2018Språk:
Engelska
Version:
01/12/2025
Filstorlek:
8.2 MB
Filnamn:
BA01880DEN_0325-00.pdf
-
Välj från de föreslagna alternativen
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individuella konfiguratorn för att fortsätta.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Letar du efter fler tillval? Använd den individuella konfiguratorn för att fortsätta.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD-ritningar CAD-ritningar
- CAD-ritningar
-
Pris per del
-
<%range%><%price%>
-
- Valbara tillägg
Individuell konfigurering
Köps ofta tillsammans
Tillbehör
Tillhörande produkter