This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
-
Ersättare
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet Tekniska egenskaper Enkelhet - F
- L
- E
- X
Fundamental urvalet
Möt dina grundläggande mätbehov
Tekniska egenskaper Enkelhet - F
- L
- E
- X
Lean urvalet
Hantera dina kärnprocesser med enkelhet
Tekniska egenskaper Enkelhet - F
- L
- E
- X
Extended urvalet
Optimera dina processer med innovativa teknologier
Tekniska egenskaper Enkelhet - F
- L
- E
- X
Xpert urvalet
Hantera dina mest utmanande applikationer
Tekniska egenskaper Enkelhet Varierande
-
-
Mätprincip
Coriolis
-
Product headline
The flowmeter for minimized cost of ownership with extended transmitter functionality. Highly accurate measurement of liquids and gases for a wide range of standard applications.
-
Sensor features
Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Compact dual‐tube system. Medium temperature up to +140 °C (+284 °F).
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 80 (⅜ to 3")
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 % (standard), 0.10 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.75 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–40 to +140 °C (–40 to +284 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
-
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN
3-A -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Marine approvals and certificates
Marine approval
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Mätprincip
Coriolis
-
Product headline
The flowmeter for minimized cost of ownership with extended transmitter functionality. Highly accurate measurement of liquids and gases for a wide range of standard applications.
-
Sensor features
Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Compact dual‐tube system. Medium temperature up to +140 °C (+284 °F).
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 80 (⅜ to 3")
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 % (standard), 0.10 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.75 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–40 to +140 °C (–40 to +284 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
-
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN
3-A -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Marine approvals and certificates
Marine approval
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A
-
Mätprincip
Coriolis
-
Characteristic / Application
An alternative to conventional volumetric flowmeters, this flowmeter has a low "cost of ownership".
-
Ambient temperature
-20...+65°C
(-4...+140°F) -
Process temperature
-40...+125°C
(-40...+257°F) -
Process pressure
PN 40...100
Cl150...600
JIS 10...63K -
Wetted parts
904L/1.4539
-
Output
4...20mA
Pulse/Frequency (10KHz, active/passive)
Relays/Status -
Certificates / Approvals
ATEX
FM
CSA
-
Mätprincip
Coriolis
-
Product headline
The flowmeter for minimized cost of ownership with extended transmitter functionality. Highly accurate measurement of liquids and gases for a wide range of standard applications.
-
Sensor features
Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Compact dual‐tube system. Medium temperature up to +140 °C (+284 °F).
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 80 (⅜ to 3")
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 % (standard), 0.10 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.75 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–40 to +140 °C (–40 to +284 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
-
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Marine approvals and certificates
Marine approval
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
-
Teknisk information (TI)
Proline Promass 80E, 83E Technical Information
-
Teknisk information (TI)
Engelsk version - 03/2018New version available in EnglishThe flowmeter for minimized cost of ownership with extended transmitter
functionalityEN SV 14/03/201816/03/201529/08/201301/02/201101/01/2010Språk:
Engelska
Version:
14/03/2018
Filstorlek:
889.9 KB
Filnamn:
TI00061DEN_1618.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 FOUNDATION Fieldbus Operating Instructions
-
Användarinstruktion (BA)
Engelsk version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System (with FOUNDATION Fieldbus
interface) for measuring the mass flow rate, density and temperatureof
fluids and gases.The description of the device functions are in a
separate documentation.EN SV 15/10/201201/10/201108/06/201001/10/200901/11/2008Språk:
Engelska
Version:
15/10/2012
Filstorlek:
2 MB
Filnamn:
BA00065DEN_1412.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 FOUNDATION Fieldbus Device Functions
-
Användarinstruktion (BA)
Engelsk version - 11/2008New version available in EnglishDescription of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 83 FOUNDATION
Fieldbus.EN SV 01/11/200801/12/200601/12/200501/12/2000Språk:
Engelska
Version:
01/11/2008
Filstorlek:
1.5 MB
Filnamn:
BA066DEN_1108.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 PROFIBUS DP/PA Description of Device Functions
-
Användarinstruktion (BA)
Engelsk version - 11/2008New version available in EnglishDescription of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 83 PR
OFIBUS-DP/-PA.EN SV 01/11/200801/01/200601/03/200501/06/2001Språk:
Engelska
Version:
01/11/2008
Filstorlek:
1.9 MB
Filnamn:
BA064DEN_1108.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 MODBUS RS485 Description of Device Functions
-
Användarinstruktion (BA)
Engelsk version - 11/2008New version available in EnglishDescriptions of the device functions (Options and In-/Outputs)
Additional documentation for Operating Instructions Promass 83 MODBUS
RS485.EN SV 01/11/200801/12/200501/11/2004Språk:
Engelska
Version:
01/11/2008
Filstorlek:
1.8 MB
Filnamn:
BA108DEN_1108.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 HART Description of Device Functions
-
Användarinstruktion (BA)
Engelsk version - 12/2014New version available in EnglishCoriolis flowmeter
EN SV 01/12/201401/09/200801/12/200501/11/200415/10/2003Språk:
Engelska
Version:
01/12/2014
Filstorlek:
1.3 MB
Filnamn:
BA00060DEN_1314.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 HART Operating Instructions
-
Användarinstruktion (BA)
Engelsk version - 12/2014New version available in EnglishCoriolis flowmeter
EN SV 01/12/201415/10/201201/10/201101/03/201001/10/2008Språk:
Engelska
Version:
01/12/2014
Filstorlek:
2.3 MB
Filnamn:
BA00059DEN_1514.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 PROFIBUS DP/PA Operating Instructions
-
Användarinstruktion (BA)
Engelsk version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System (with PROFIBUS DP/PA interface)
for measuring the mass flow rate, density and temperature of fluids and
gases. The description of the device functions are in a separate
documentation.EN SV 15/10/201201/10/201108/06/201001/11/200801/08/2007Språk:
Engelska
Version:
15/10/2012
Filstorlek:
3.6 MB
Filnamn:
BA00063DEN_1412.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 Modbus RS485 Operating Instructions
-
Användarinstruktion (BA)
Engelsk version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System (with Modbus RS485
interface) for measuring the mass flow rate, density and temperature of
fluids and gases.The description of the device functions are in a
separate documentation.EN SV 15/10/201201/10/201108/06/201001/11/2008Språk:
Engelska
Version:
15/10/2012
Filstorlek:
2.5 MB
Filnamn:
BA00107DEN_1412.pdf
-
-
-
Kortfattad instruktion (KA)
Proline Promass 83 Brief Operating Instructions
-
Kortfattad instruktion (KA)
Engelsk version - 05/2016New version available in EnglishCoriolis flowmeter
EN SV 26/05/201606/08/201515/10/201201/10/201101/03/2011Språk:
Engelska
Version:
26/05/2016
Filstorlek:
2 MB
Filnamn:
KA00024DEN_1716.pdf
-