This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
-
Ersättare
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet Tekniska egenskaper Enkelhet - F
- L
- E
- X
Fundamental urvalet
Möt dina grundläggande mätbehov
Tekniska egenskaper Enkelhet - F
- L
- E
- X
Lean urvalet
Hantera dina kärnprocesser med enkelhet
Tekniska egenskaper Enkelhet - F
- L
- E
- X
Extended urvalet
Optimera dina processer med innovativa teknologier
Tekniska egenskaper Enkelhet - F
- L
- E
- X
Xpert urvalet
Hantera dina mest utmanande applikationer
Tekniska egenskaper Enkelhet Varierande
-
-
Mätprincip
Coriolis
-
Product headline
The specialist for life sciences with extended transmitter functionality. Dedicated for applications under sterile conditions in the life sciences industry.
-
Sensor features
Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. ASME BPE, 3-A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L).
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (⅜ to 2")
-
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 63, Class 300, 40K
-
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus
RS485, EtherNet/IP -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
PED, CRN
3-A, FDA, ASME BPE, ISPE -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, FDA, ASME BPE, ISPE
-
Mätprincip
Coriolis
-
Product headline
The specialist for life sciences with extended transmitter functionality. Dedicated for applications under sterile conditions in the life sciences industry.
-
Sensor features
Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. ASME BPE and 3-A conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L).
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (⅜ to 2")
-
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 63, Class 300, 40K
-
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus
RS485, EtherNet/IP -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
PED, CRN
3-A, FDA, ASME BPE, ISPE -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, FDA, ASME BPE, ISPE
-
Mätprincip
Coriolis
-
Characteristic / Application
Coriolis mass flowmeter complying with ASME BPE, ISPE, FDA, 3-A
-
Ambient temperature
-20...+65°C
(-4...+140°F) -
Process temperature
-50...+200°C
(-58...+392°F) -
Process pressure
PN 16...40
Cl 150...300
JIS 20...40K -
Wetted parts
316L/1.4435
-
Output
4...20mA
Pulse/Frequency (10KHz, active/passive)
Relays/Status -
Certificates / Approvals
ATEX
FM
CSA IECEx TIIS NEPSI
-
Mätprincip
Coriolis
-
Product headline
The specialist for life sciences with extended transmitter functionality. Dedicated for applications under sterile conditions in the life sciences industry.
-
Sensor features
Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. ASME BPE, 3-A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L).
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (⅜ to 2")
-
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 63, Class 300, 40K
-
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus
RS485, EtherNet/IP -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, FDA, ASME BPE, ISPE
-
-
Teknisk information (TI)
Proline Promass 80P, 83P Technical Information
-
Teknisk information (TI)
Engelsk version - 04/2015New version available in EnglishThe specialist for life sciences with extended transmitter functionality
EN SV 01/04/201515/12/201005/11/201025/01/201009/07/2009Språk:
Engelska
Version:
01/04/2015
Filstorlek:
1.4 MB
Filnamn:
TI00078DEN_1415.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 FOUNDATION Fieldbus Operating Instructions
-
Användarinstruktion (BA)
Engelsk version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System (with FOUNDATION Fieldbus
interface) for measuring the mass flow rate, density and temperatureof
fluids and gases.The description of the device functions are in a
separate documentation.EN SV 15/10/201201/10/201108/06/201001/10/200901/11/2008Språk:
Engelska
Version:
15/10/2012
Filstorlek:
2 MB
Filnamn:
BA00065DEN_1412.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 FOUNDATION Fieldbus Device Functions
-
Användarinstruktion (BA)
Engelsk version - 11/2008New version available in EnglishDescription of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 83 FOUNDATION
Fieldbus.EN SV 01/11/200801/12/200601/12/200501/12/2000Språk:
Engelska
Version:
01/11/2008
Filstorlek:
1.5 MB
Filnamn:
BA066DEN_1108.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 PROFIBUS DP/PA Description of Device Functions
-
Användarinstruktion (BA)
Engelsk version - 11/2008New version available in EnglishDescription of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 83 PR
OFIBUS-DP/-PA.EN SV 01/11/200801/01/200601/03/200501/06/2001Språk:
Engelska
Version:
01/11/2008
Filstorlek:
1.9 MB
Filnamn:
BA064DEN_1108.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 HART Description of Device Functions
-
Användarinstruktion (BA)
Engelsk version - 12/2014New version available in EnglishCoriolis flowmeter
EN SV 01/12/201401/09/200801/12/200501/11/200415/10/2003Språk:
Engelska
Version:
01/12/2014
Filstorlek:
1.3 MB
Filnamn:
BA00060DEN_1314.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 MODBUS RS485 Description of Device Functions
-
Användarinstruktion (BA)
Engelsk version - 11/2008New version available in EnglishDescriptions of the device functions (Options and In-/Outputs)
Additional documentation for Operating Instructions Promass 83 MODBUS
RS485.EN SV 01/11/200801/12/200501/11/2004Språk:
Engelska
Version:
01/11/2008
Filstorlek:
1.8 MB
Filnamn:
BA108DEN_1108.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 HART Operating Instructions
-
Användarinstruktion (BA)
Engelsk version - 12/2014New version available in EnglishCoriolis flowmeter
EN SV 01/12/201415/10/201201/10/201101/03/201001/10/2008Språk:
Engelska
Version:
01/12/2014
Filstorlek:
2.3 MB
Filnamn:
BA00059DEN_1514.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 PROFIBUS DP/PA Operating Instructions
-
Användarinstruktion (BA)
Engelsk version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System (with PROFIBUS DP/PA interface)
for measuring the mass flow rate, density and temperature of fluids and
gases. The description of the device functions are in a separate
documentation.EN SV 15/10/201201/10/201108/06/201001/11/200801/08/2007Språk:
Engelska
Version:
15/10/2012
Filstorlek:
3.6 MB
Filnamn:
BA00063DEN_1412.pdf
-
-
-
Användarinstruktion (BA)
Proline Promass 83 Modbus RS485 Operating Instructions
-
Användarinstruktion (BA)
Engelsk version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System (with Modbus RS485
interface) for measuring the mass flow rate, density and temperature of
fluids and gases.The description of the device functions are in a
separate documentation.EN SV 15/10/201201/10/201108/06/201001/11/2008Språk:
Engelska
Version:
15/10/2012
Filstorlek:
2.5 MB
Filnamn:
BA00107DEN_1412.pdf
-
-
-
Kortfattad instruktion (KA)
Proline Promass 83 Brief Operating Instructions
-
Kortfattad instruktion (KA)
Engelsk version - 05/2016New version available in EnglishCoriolis flowmeter
EN SV 26/05/201606/08/201515/10/201201/10/201101/03/2011Språk:
Engelska
Version:
26/05/2016
Filstorlek:
2 MB
Filnamn:
KA00024DEN_1716.pdf
-