©Endress+Hauser
©Endress+Hauser
En överblick över specifikationer
Measured variables
CH4, CO, CO2, Corg, HCl, H2O, NH3, NO, NO2, N2O, O2, SO2
Ambient temperature range
Applikationsområde
The MCS200HW is a analyzer system for continuous monitoring of up to 10 IR measurement components in flue gases. All parts which touch media are heated above the dew point and therefore protected from corrosion. Internal reference point monitoring allows for a quick check of the measured values without test gases. The web display and the task assistant integrated in the software makes operation very easy. MCS200HW Ex allows reliable emission measurement even in explosion-hazardous areas.
Emission monitoring for waste incineration plants as well as power plants and plants with co-incineration, e.g. cement plants
Measurement of nitrogen oxides in nitric acid plants
Device properties:
Measurement of up to 10 IR components plus O2 and TOC
Wear-free gas distribution through ejector pumps
Reference point monitoring with internal calibration cells
Web server for platform-independent device control
Use of dry test gases for HCl and NH3
Classification for ATEX Zone 2, IIC T3 gb
Fördelar
Only one analyzer necessary for simultaneous monitoring of up to 12 gas components
Convenient, task-oriented operation
Remote access without additional software
High availability due to certified internal third-party monitoring (QAL3) without test gases
Data transmission possible via just one interface
Use in explosion-hazardous areas thanks to rugged, pressurized housing
Xpert urvalet
Specialprodukter
Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
©Endress+Hauser
Enkla produkter
Enkla att välja, installera och använda
Tekniska egenskaper
Enkelhet
Standardprodukter
Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
High-end produkter
Mycket funktionella och praktiska
Tekniska egenskaper
Enkelhet
Specialprodukter
Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
FLEX urvalet
Tekniska egenskaper
Enkelhet
Fundamental urvalet
Möt dina grundläggande mätbehov
Tekniska egenskaper
Enkelhet
Lean urvalet
Hantera dina kärnprocesser med enkelhet
Tekniska egenskaper
Enkelhet
Extended urvalet
Optimera dina processer med innovativa teknologier
Tekniska egenskaper
Enkelhet
Xpert urvalet
Hantera dina mest utmanande applikationer
Tekniska egenskaper
Enkelhet
Loading alternative products
Kundcase
Säkerhetskontroll av råvaror
Melamin övervakar överföringen av lösningsmedel för att säkerställa korrekt leverans från lastbilar till de rätta tankarna i den kemiska industrin.
Läs hela berättelsen
Mätning av vätgaskvalitet i realtid
Enapter använder optisk analytisk mätteknik från Endress+Hauser för att fastställa renheten hos den vätgas som framställs. Läs mer!
Läs hela berättelsen
Mätprincip
Interference filter correlation, Gas filter correlation
Measured variables
CH4, CO, CO2, Corg, HCl, H2O, NH3, NO, NO2, N2O, O2, SO2
Performance-tested measurands
CH4, CO, CO2, Corg, HCl, H2O, NH3, NO, NO2, N2O, O2, SO2
Certified measuring ranges
CH4: 0 ... 50 mg/m³ / 0 ... 500 mg/m³ CO: 0 ... 30 mg/m³ / 0 ... 10,000 mg/m³ CO2: 0 ... 25% by vol. Corg: 0 ... 15 mg/m³ / 0 ... 50 mg/m³ / 0 ... 150 mg/m³ / 0 ... 500 mg/m³ HCl: 0 ... 15 mg/m³ / 0 ... 3,000 mg/m³ H2O: 0 ... 40% by vol. NH3: 0 ... 7 mg/m³ / 0 ... 500 mg/m³ NO: 0 ... 50 mg/m³ / 0 ... 2,500 mg/m³ NO2: 0 ... 50 mg/m³ / 0 ... 500 mg/m³ N2O: 0 ... 45 mg/m³ / 0 ... 2,000 mg/m³ O2: 0 ... 25% by vol. SO2: 0 ... 75 mg/m³ / 0 ... 2,500 mg/m³
Ambient temperature range
Ambient humidity
≤ 90 % Relative humidity; non-condensing
Conformities
Approved for plants requiring approval 2000/76/EC (17. BImSchV) 2001/80/EC (13. BImSchV) 27. BImSchV EN 15267 EN 14181
Hazardous area approvals
MCS200HW Ex: ATEX: II 3G Ex dc ec ic [ic] mc nC pzc IIC T3 Gc Analyzer cabinet II 3G Ex ec IIC T3 Gc Gas sampling unit I 2G Ex eb IIC T Gb Sample gas line IECEx: on request.
Degree of protection
MCS200HW: IP54 MCS200HW Ex: IP65
Mest nedladdade
Conditioning of Instrument Air for Analyzer Solutions
Engelsk version - 01/2025
The intended use of the Instrument Air Conditioning Unit is to supply a
measuring device with clean, filtered and conditioned instrument air.
Språk:
Engelska
Version:
01/01/2025
Filstorlek:
2.3 MB
Filnamn:
8029824_AE00_KA_Instrument_Air_Conditioning_en_V1-0_2019-03_EHS_WEB.pdf
MCS200HW-MP
Engelsk version - 06/2025
Multicomponent Gas Analyzer, Mounting Plate Version
EN
SV
DE
01/06/2025
01/01/2025
Språk:
Engelska
Version:
01/06/2025
Filstorlek:
6.6 MB
Filnamn:
8029890_1SIK_OI_MCS200HW-MP_en_V1-1_2025-06_EHS.pdf
18 dokument
Multicomponent Gas Analyzer, Mounting Plate Version
EN
SV
Tyska
01/06/2025
01/01/2025
Språk:
Engelska
Version:
01/06/2025
Filstorlek:
6.6 MB
Filnamn:
8029890_1SIK_OI_MCS200HW-MP_en_V1-1_2025-06_EHS.pdf
EN
SV
Danska Tyska Estniska French Italienska Holländska Norska Portugisiska Ryska
01/01/2025
Språk:
Engelska
Version:
01/01/2025
Filstorlek:
2.6 MB
Filnamn:
8029819_YJ80_OI_SFU_IP23_en_V3-0_2015-08_EHS.pdf
SFU weatherproof enclosure
Gas Sampling Unit with Weatherproof Enclosure
EN
SV
Tyska Italienska
01/01/2025
Språk:
Engelska
Version:
01/01/2025
Filstorlek:
2.6 MB
Filnamn:
8029817_14SF_OI_SFU_IP54_en_V1-1_2019-07_EHS.pdf
Gasanalysator för flera gaskomponenter
EN
SV
Danska Tyska Spanska Finska French Ungerska Italienska Portugisiska Ryska Turkiska Kinesiska
01/06/2025
01/01/2025
Språk:
Svenska
Version:
01/06/2025
Filstorlek:
5 MB
Filnamn:
8030360_AE00_OI_MCS200HW_sv_V3-3_2025-06_EHS.pdf
MCS200HW and GMS800 FIDOR
This document describes the MCS200HW & GMS800 FIDOR and provides information for the entire life cycle of the analyzer system.
Språk:
Engelska
Version:
01/01/2025
Filstorlek:
2.3 MB
Filnamn:
8030592_OI_MCS200HW-FIDOR_en_V2-0_2023-07_EHS.pdf
Multi-Component Gas Analyzer
EN
SV
Tyska
01/06/2025
01/01/2025
Språk:
Engelska
Version:
01/06/2025
Filstorlek:
8.3 MB
Filnamn:
8029892_1SIK_OI_MCS200HW_Ex_en_V1-1_2025-06_EHS.pdf
Conditioning of Instrument Air for Analyzer Solutions
The intended use of the Instrument Air Conditioning Unit is to supply a measuring device with clean, filtered and conditioned instrument air.
Språk:
Engelska
Version:
01/01/2025
Filstorlek:
2.3 MB
Filnamn:
8029824_AE00_KA_Instrument_Air_Conditioning_en_V1-0_2019-03_EHS_WEB.pdf
for non-Ex analyzer devices (multi-lingual, also in DE, BG, CS, DA, EL, ES, ET, FI, FR, HR, HU, IT, LT, LV, NL, NO, PL, PT, RO, RU, SK, SL, SV)
Språk:
Engelska
Version:
01/01/2025
Filstorlek:
2.4 MB
Filnamn:
8030257_XA_Safety_Information_non-Ex_ml_V1-0_2016-06_WEB.pdf
MCS200HW, MCS200HW-MP – Sample point switching
Documentation on operating MCS200HW, MCS200HW-MP with with several sample points or in a master-redundant network
Språk:
Engelska
Version:
01/01/2025
Filstorlek:
1.3 MB
Filnamn:
8030981_AE00_SD_MCS200HW_sample_point_switch_en_V1-0_2022-02_EHS.pdf
Document for entering initial passwords. / Dokument für die Eingabe initialer Passwörter.
Språk:
Engelska
Version:
12/02/2026
Filstorlek:
135.9 KB
Filnamn:
8031724_AE00_Webdisplay_Startpassword_ml_V2-0_2026-02_EHS.pdf
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
MAINTENANCE KIT SAMPLING SILC. MESH
FILTERPLATE 12012010MM SYN.FIBRE
Vi värdesätter din integritet
Vi använder cookies för att förbättra din användarupplevelse, samla in statistik för att optimera webbplatsens funktionalitet och leverera skräddarsydda annonser eller innehåll.
Välj "Acceptera alla", för att samtycka till vår användning av cookies.
För mer information se vår Cookie Policy .
Anpassa
Acceptera endast det väsentliga
Acceptera alla