En överblick över specifikationer
-
Process temperature
0 to 140 °C (32 to 284 °F)
-
Process pressure
0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation
Applikationsområde
The Cleanfit CPA472D assembly is designed for harsh process conditions. It offers a great variety of rugged materials to operate your sensors safely even under high pressure, high temperature or in aggressive media. The assembly allows you to replace sensors without interrupting the process or to clean and calibrate them automatically via the optional control system. Benefit from easy, time-saving sensor handling and an extended operating life of the sensors.
The Cleanfit CPA472D is intended for installation in tanks or pipes in:
Chemical industry
Power plants
Biodiesel plants
It is suitable for use with pressures of up to 10 bar.
Fördelar
Extremely robust: Suitable for use with pressures of up to 10 bar and temperatures of up to 140° C even as PEEK, PVDF, conductive PVDF versions
Maximum chemical resistance ensures long operating times
No process interruption for electrode cleaning and calibration – saves maintenance time and costs
Flexible adaptation to all applications by great variety of materials and process connections
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
| FLEX urvalet | Tekniska egenskaper | Enkelhet |
|---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
-
Mätprincip
Potentiometric
-
Application
Chemical industry, biodiesel plants, power plants, plant design, tanks, process vats or pipes
-
Installation
Retractable holder
-
Characteristic
For tanks and process vats and pipelines or pipes (min. DN80)
The robust retractable assembly permits replacement of the electrode while the tank is full or under process conditions with pressures of up to 6 bar -
Design
Manual or pneumatical
-
Material
Electrode holder, rinse chamber and raised face:
PEEK, PVDF, conductive PVDF, Alloy C22, stainless steel 1.4571
Seals: EPDM, FPM (Viton) or FFKM (Kalrez®) -
Dimension
Immersion depth: 146 or 280 mm (5.75 or 7.87 inch)
-
Process temperature
0 to 140 °C (32 to 284 °F)
-
Process pressure
0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation -
Connection
Process connections: Flange DN 50, DN 80, ANSI 2", JIS IS10K50A, internal thread G1¼
-
Mätprincip
Sensor ORP / Redox
-
Application
Chemical industry, biodiesel plants, power plants, plant design, tanks, process vats or pipes
-
Installation
Retractable holder
-
Characteristic
For tanks and process vats and pipelines or pipes (min. DN80)
The robust retractable assembly permits replacement of the electrode while the tank is full or under process conditions with pressures of up to 6 bar -
Design
Manual or pneumatical
-
Material
Electrode holder, rinse chamber and raised face:
PEEK, PVDF, conductive PVDF, Alloy C22, stainless steel 1.4571
Seals: EPDM, FPM (Viton) or FFKM (Kalrez®) -
Dimension
Immersion depth: 146 or 280 mm (5.75 or 7.87 inch)
-
Process temperature
0 to 140 °C (32 to 284 °F)
-
Process pressure
0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation -
Connection
Process connections: Flange DN 50, DN 80, ANSI 2", JIS IS10K50A, internal thread G1¼
-
-
Teknisk information (TI)
Technical Information Cleanfit P CPA472D
-
Teknisk information (TI)
Engelsk version - 10/2013New version available in EnglishRetractable process assembly for pH, ORP and other industry electrodes
Heavy duty versionEN SV 08/10/201301/06/201001/05/2006Språk:
Engelska
Version:
08/10/2013
Filstorlek:
940.5 KB
Filnamn:
TI00403CEN_1313.pdf
-
-
-
Teknisk information (TI)
Technical Information Topcal S CPC310
-
Teknisk information (TI)
Engelsk version - 07/2015New version available in EnglishFully automatic measuring, cleaning and calibration system in hazardous
and non-hazardous areasEN SV 22/07/201501/07/2006Språk:
Engelska
Version:
22/07/2015
Filstorlek:
2 MB
Filnamn:
TI00404CEN_1315.pdf
-
-
-
Användarinstruktion (BA)
Operating Instructions Cleanfit CPA472D
-
Användarinstruktion (BA)
Engelsk version - 10/2013New version available in EnglishRetractable Process Assembly
EN SV 08/10/201301/09/201001/05/2006Språk:
Engelska
Version:
08/10/2013
Filstorlek:
1.3 MB
Filnamn:
BA00403CEN_1313.pdf
-
-
-
Installationsanvisningar (EA)
EA for Cleanfit CPA472D
-
Installationsanvisningar (EA)
Engelsk version - 02/2025New version available in EnglishService Manual for Retractable Process Assembly Cleanfit CPA472D
EN SV 20/02/2025Språk:
Engelska
Version:
20/02/2025
Filstorlek:
3.1 MB
Filnamn:
71217188_Service_CPA472D.pdf
-
-
-
Installationsanvisningar (EA)
EA retrofit for Cleanfit CPA472D
-
Installationsanvisningar (EA)
Engelsk version - 02/2025New version available in EnglishRetrofit manual of retractable process assembly Cleanfit CPA472D
EN SV 20/02/2025Språk:
Engelska
Version:
20/02/2025
Filstorlek:
3.8 MB
Filnamn:
71297785_Umbau_CPA472D.pdf
-
-
-
Installationsanvisningar (EA)
EA Kits/Kit for CPA47x
-
Installationsanvisningar (EA)
Engelsk version - 09/2025New version available in EnglishSpare parts kits for CPA47x limit switches
EN SV 09/09/2025Språk:
Engelska
Version:
09/09/2025
Filstorlek:
962.5 KB
Filnamn:
71201542_cpa47x_endlagenschalter.pdf
-
-
-
Installationsanvisningar (EA)
EA Spare parts kits for Cleanfit CPA472D, CPA473 and CPA474 process retractable assemblies
-
Installationsanvisningar (EA)
Engelsk version - 02/2025New version available in EnglishSeals, not in contact with medium
EN SV 19/02/2025Språk:
Engelska
Version:
19/02/2025
Filstorlek:
934.3 KB
Filnamn:
EA01523CEN_0125-00.pdf
-
-
-
Kompetensbroschyr (CP)
pH-Messung in Industrieprozessen
-
Kompetensbroschyr (CP)
Tysk version - 12/2021New version available in EnglishAuswahl- und Engineering-Hilfe für verschiedene Industriebranchen und
ApplikationenSpråk:
Tyska
Version:
01/12/2021
Filstorlek:
3.3 MB
Filnamn:
CP00010CDE_1621_pH Auswahlhilfe_2021.pdf
-
-
-
Kompetensbroschyr (CP)
産業プロセスにおけるpH測定
-
Kompetensbroschyr (CP)
Japansk version - 02/2024New version available in Englishさまざまな産業およびアプリケーション向けのpH測定セレクションガイド
Språk:
Japanska
Version:
08/02/2024
Filstorlek:
2.6 MB
Filnamn:
CP00010CJA_1315_1024_pH_selection_guide.pdf
-
-
-
Kompetensbroschyr (CP)
pH measurement in industrial processes
-
Kompetensbroschyr (CP)
Engelsk version - 12/2021New version available in EnglishSelection and engineering guide for different industries and
applicationsSpråk:
Engelska
Version:
02/12/2021
Filstorlek:
3.2 MB
Filnamn:
CP00010CEN_1621_pH selection guide_2021.pdf
-
Välj från de föreslagna alternativen
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individuella konfiguratorn för att fortsätta.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Letar du efter fler tillval? Använd den individuella konfiguratorn för att fortsätta.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD-ritningar CAD-ritningar
- CAD-ritningar
-
Pris per del
-
<%range%><%price%>
-
- Valbara tillägg
Individuell konfigurering
Köps ofta tillsammans
Tillbehör
Tillhörande produkter