Digital differential pressure transmitter, capacitive sensor with ceramic diaphragm Safety by function monitoring and membrane detection, modular transmitter design
Max. measurement error
0,1%
Max. process pressure
max. 100 bar (max. 1.450 psi)
Medium temperature range
Temperature gradient from pressure piping
Display/Operation
Option
Outputs
4 ... 20mA HART PROFIBUS PA FOUNDATION Fieldbus
Digital communication
HART PROFIBUS PA Fondation Fieldbus
Hazardous area approvals
ATEX FM CSA
Product headline
Digital differential pressure transmitter, capacitive sensor with ceramic diaphragm Safety by function monitoring and membrane detection, modular transmitter design
Max. measurement error
0,1%
Max. process pressure
max. 100 bar (max. 1.450 psi)
Medium temperature range
Temperature gradient from pressure piping
Display/Operation
Option
Outputs
4 ... 20mA HART PROFIBUS PA FOUNDATION Fieldbus
Digital communication
HART PROFIBUS PA Fondation Fieldbus
Hazardous area approvals
ATEX FM CSA
Characteristic
Digital differential pressure transmitter, capacitive sensor with ceramic diaphragm Safety by function monitoring and membrane detection, modular transmitter design
Supply voltage
4...20mA / HART: 11,5...45V DC Ex: 11,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC Ex: 9...24V DC
Reference Accuracy
0,1%
Long term stability
0,1% of URL/year 0,25% of URL/5 years
Process temperature
-40°C...85°C
Ambient temperature
-40°C...85°C
Measuring cell
25mbar...3bar
Max. Turn down
max. 100:1
Max. overpressure limit
100bar
Process connection
1/4-18NPT RC1/4"
Communication
4 ... 20mA HART PROFIBUS PA FOUNDATION Fieldbus
Certificates / Approvals
ATEX FM CSA SIL WHG/overspill protection EN10204-3.1
Successor
PMD70
Product headline
Digital differential pressure transmitter, capacitive sensor with ceramic diaphragm Safety by function monitoring and membrane detection, modular transmitter design
Max. measurement error
0,1%
Max. process pressure
max. 100 bar (max. 1.450 psi)
Medium temperature range
Temperature gradient from pressure piping
Display/Operation
Option
Outputs
4 ... 20mA HART PROFIBUS PA FOUNDATION Fieldbus
Digital communication
HART PROFIBUS PA Fondation Fieldbus
Hazardous area approvals
ATEX FM CSA
Characteristic / Application
Digital differential pressure transmitter, capacitive sensor with ceramic diaphragm Safety by function monitoring and membrane detection, modular transmitter design
Supply / Communication
4 ... 20 mA / HART: 11,5...45V DC Ex: 11,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC Ex: 9...24V DC
Accuracy
0,1%
Long term stability
0,1% of URL/year 0,25% of URL/5 years
Ambient temperature
-40°C...85°C
Process temperature
-40°C...85°C
Process pressure / max. overpressure limit
100bar
Pressure measuring range
25mbar...3bar
Main wetted parts
Alloy C 316L Monel Tantal
Process connection
1/4-18NPT RC1/4"
Max. measurement distance
30m H2O
Communication
4 ... 20 mA HART PROFIBUS PA FOUNDATION Fieldbus
Certificates / Approvals
ATEX FM CSA SIL WHG/overspill protection EN10204-3.1