  • Mätprincip

    Hydrostatic

  • Characteristic

    Pressure transmitter, gauge for hydrostatic level measurement, flush mounted CONTITE-sensor with metallic measuring diaphragm Alloy C4 hermetically welded + safe humidity protection
    Compact version

  • Supply voltage

    3-wire analogue:
    15...20V DC
    2-wire PFM-Signal:
    14...16V DC
    4...20mA HART:
    11,5...30V DC
    PROFIBUS PA:
    9...24V DC
    Ex ia: 9...32V DC
    FOUNDATION Fieldbus:
    9...32V DC

  • Reference Accuracy

    0,2%
    optional 0,1%

  • Long term stability

    0,1% of URL/6 months

  • Process temperature

    -10°C...100°C

  • Ambient temperature

    -40°C...85°C

  • Measuring cell

    100mbar...10bar

  • Max. Turn down

    max. 10:1

  • Max. overpressure limit

    25bar

  • Process connection

    Threads
    Flanges (DIN, ASME, JIS)

  • Communication

    3-wire analogue
    2-wire PFM
    4...20mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX
    CSA
    TIIS
    WHG/overspill protection
    GL marine

  • Successor

    FMB70

  • Mätprincip

    Hydrostatic

  • Characteristic / Application

    Pressure transmitter, gauge for hydrostatic level measurement, flush mounted CONTITE-sensor with metallic measuring diaphragm Alloy C4 hermetically welded + safe humidity protection
    Compact version

  • Supply / Communication

    3-wire analogue:
    15...20V DC
    2-wire PFM-Signal:
    14...16V DC
    4...20mA HART:
    11,5...30V DC
    PROFIBUS PA:
    9...24V DC
    Ex ia: 9...32V DC
    FOUNDATION Fieldbus:
    9...32V DC

  • Accuracy

    0,2%
    optional 0,1%

  • Long term stability

    0,1% of URL/6 months

  • Ambient temperature

    -40°C...85°C

  • Process temperature

    -10°C...100°C

  • Process pressure absolute / max. overpressure limit

    25bar

  • Pressure measuring range

    100mbar...10bar

  • Main wetted parts

    Alloy C
    316L

  • Process connection

    Threads
    Flanges (DIN, ASME, JIS)

  • Max. measurement distance

    100m H2O

  • Communication

    3-wire analogue
    2-wire PFM
    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX
    CSA
    TIIS
    WHG/overspill protection
    GL marine

  • Options

    digital display
    SS-, Aluminium- or Polyesterhousing

  • Successor

    FMB70

  • Application limits

    Changing density

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification
  • 21
    • Nr 21 Order code 52008495

      Sealing set EPDM 73.0x3.0, 10 pieces

      Usage: cover.

  • 20
    • Nr 20 Order code 52002593

      Cover F6 Alu, high, gasket

      O-ring EPDM. Usage: housing F6, aluminium.

    • Nr 20 Order code 52002594

      Cover F10 PBT, high, gasket

      O-ring VMQ. Usage: housing F10, Polyester.

    • Order code 917755-0000

      Protection cover, PFA

      Usage: DB4x/DB5x, FMX165, FMX167/FMX21 42mm.

    • Order code 52014047

      Sealing ring DIN7603-A 48x55 FA, 5pcs.

      Process gasket. Usage: process connections G1-1/2.

    • Order code 52024469

      Weld-in adapter G1-1/2, 316L

      Mounting process connection G1-1/2. Material: 316L. Correct installation only with dummy. Usage: FMB50/FMB51/FMB52, FMB70, PMC51, PMC71, PMP51/PMP55, PMP71/PMP75.

    • Order code 52024470

      Weld-in adapter G1-1/2, 316L, 3.1

      Mounting process connection G1-1/2. Material: 316L. Inspection cert. EN10204-3.1 material. Usage: FMB50/FMB51/FMB52, FMB70, PMC51, PMC71, PMP51/PMP52, PMP71/PMP75.

    • Order code Info_01002
    • Order code Info_01003
    • Order code Info_01005
  • Föregångare

  • Ersättare