- F
- L
- E
- X
Proline Promass O 500 for the oil and gas industry with different remote transmitters
- F
- L
- E
- X
Proline Promass O 500 for the oil and gas industry
Proline Promass O 500 for the oil and gas industry with different remote transmitters
En överblick över specifikationer
-
Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 850 lb/min)
-
Medium temperature range
–40 to +205 °C (–40 to +401 °F)
-
Max. process pressure
PN 250, Class 1500
-
Wetted materials
Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750)
Connection: 25Cr duplex (Super Duplex), 1.4410 (F53)
Applikationsområde
Promass O is designed for premium accuracy of liquids and gases at the highest process pressures in the oil and gas industry. The sensor is fully suitable for offshore conditions and resistant to stress corrosion cracking. With its innovative remote transmitter Promass O 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables safe processes.
Measuring principle operates independently of physical fluid properties such as viscosity or density
For premium accuracy at highest process pressures, fully suitable for offshore conditions
Device properties
Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750)
Process pressure up to PN 250 (Class 1500)
Nominal diameter: DN 80 to 250 (3 to 10")
Remote version with up to 4 I/Os
Backlit display with touch control and WLAN access
Standard cable between sensor and transmitter
Fördelar
Maximum safety – highest resistance to stress corrosion cracking
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no in-/outlet run needs
Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Videor
-
The Coriolis Flow Measuring Principle
Föregångare
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
| FLEX urvalet | Tekniska egenskaper | Enkelhet |
|---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
-
Mätprincip
Coriolis
-
Product headline
Robust high-pressure flowmeter, as remote version with up to 4 I/Os.
For premium accuracy at highest process pressures, fully suitable for offshore conditions. -
Sensor features
Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
DN 80 to 250 (3 to 10")
-
Wetted materials
Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750)
Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 850 lb/min)
-
Max. process pressure
PN 250, Class 1500
-
Medium temperature range
–40 to +205 °C (–40 to +401 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4404 (316L), highest corrosion resistance
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG
OIML R117 Liquids other than water, Cryogenic Liquids, LPG
MI-002, PTB -
Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval, CCS approval
-
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
-
Mätprincip
Coriolis
-
Product headline
Robust high-pressure flowmeter, as remote version with up to 4 I/Os.
For premium accuracy at highest process pressures, fully suitable for offshore conditions. -
Sensor features
Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
DN 80 to 250 (3 to 10")
-
Wetted materials
Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750)
Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 850 lb/min)
-
Max. process pressure
PN 250, Class 1500
-
Medium temperature range
–40 to +205 °C (–40 to +401 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4404 (316L), highest corrosion resistance
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG
OIML R117 Liquids other than water, Cryogenic Liquids, LPG
MI-002, PTB -
Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval, CCS approval
-
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
-
Mätprincip
Coriolis
-
Product headline
Robust high-pressure flowmeter, as remote version with up to 4 I/Os.
For premium accuracy at highest process pressures, fully suitable for offshore conditions. -
Sensor features
Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
DN 80 to 150 (3 to 6")
-
Wetted materials
Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750)
Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 800 000 kg/h (0 to 29 400 lb/min)
-
Max. process pressure
PN 250, Class 1500
-
Medium temperature range
–40 to +205 °C (–40 to +401 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4404 (316L), highest corrosion resistance
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG
OIML R117 Liquids other than water, Cryogenic Liquids, LPG
MI-002, PTB -
Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval, CCS approval
-
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
-
Mätprincip
Coriolis
-
Product headline
Robust high-pressure flowmeter, as remote version with up to 4 I/Os.
For premium accuracy at highest process pressures, fully suitable for offshore conditions. -
Sensor features
Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
DN 80 to 250 (3 to 10")
-
Wetted materials
Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750)
Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 850 lb/min)
-
Max. process pressure
PN 250, Class 1500
-
Medium temperature range
–40 to +205 °C (–40 to +401 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4404 (316L), highest corrosion resistance
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG
OIML R117 Liquids other than water, Cryogenic Liquids, LPG
MI-002, PTB -
Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval, CCS approval
-
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
-
-
Teknisk information (TI)
TI Proline Promass O 500
-
Teknisk information (TI)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
EN SV 01/12/202511/11/202501/11/202429/03/202401/08/2022Språk:
Engelska
Version:
01/12/2025
Filstorlek:
9.4 MB
Filnamn:
TI01285DEN_1225-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass O 500
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
EtherNet/IPEN SV 01/12/202501/01/202102/10/2017Språk:
Engelska
Version:
01/12/2025
Filstorlek:
9.6 MB
Filnamn:
BA01753DEN_0425-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass O 500
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
PROFINET over Ethernet-APLEN SV 01/12/202501/11/202408/01/2024Språk:
Engelska
Version:
01/12/2025
Filstorlek:
9.7 MB
Filnamn:
BA02127DEN_0325-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass O 500
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
PROFIBUS PAEN SV 01/12/202501/11/202401/01/202101/11/201801/08/2016Språk:
Engelska
Version:
01/12/2025
Filstorlek:
8.9 MB
Filnamn:
BA01554DEN_0525-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass O 500
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
Modbus TCPEN SV 15/12/202511/11/2025Språk:
Engelska
Version:
15/12/2025
Filstorlek:
8.5 MB
Filnamn:
BA02418DEN_0225-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass O 500
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
PROFIBUS DPEN SV 01/12/202501/01/202101/06/2018Språk:
Engelska
Version:
01/12/2025
Filstorlek:
8.3 MB
Filnamn:
BA01876DEN_0425-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass O 500
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
FOUNDATION FieldbusEN SV 01/12/202501/11/202401/01/202101/11/2016Språk:
Engelska
Version:
01/12/2025
Filstorlek:
8.7 MB
Filnamn:
BA01565DEN_0425-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass O 500
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
Modbus RS485EN SV 01/12/202501/08/202201/01/202101/09/201901/12/2018Språk:
Engelska
Version:
01/12/2025
Filstorlek:
8.7 MB
Filnamn:
BA01543DEN_0825-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass O 500
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
PROFINETEN SV 01/12/202501/01/202116/09/201915/07/201902/10/2017Språk:
Engelska
Version:
01/12/2025
Filstorlek:
10.5 MB
Filnamn:
BA01764DEN_0625-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Promass O 500
-
Användarinstruktion (BA)
Engelsk version - 12/2025New version available in EnglishCoriolis flowmeter
HARTEN SV 01/12/202501/11/202401/08/202201/01/202101/09/2019Språk:
Engelska
Version:
01/12/2025
Filstorlek:
9 MB
Filnamn:
BA01532DEN_0725-00.pdf
-
Välj från de föreslagna alternativen
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individuella konfiguratorn för att fortsätta.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Letar du efter fler tillval? Använd den individuella konfiguratorn för att fortsätta.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD-ritningar CAD-ritningar
- CAD-ritningar
-
Pris per del
-
<%range%><%price%>
-
- Valbara tillägg
Individuell konfigurering
Köps ofta tillsammans
Tillbehör
Tillhörande produkter