Omnigrad S TAF12T
High temperature TC thermometer

Omnigrad S TAF12T
High temperature TC thermometer ©Endress+Hauser
Omnigrad S TAF12T
High temperature TC thermometer ©Endress+Hauser
Omnigrad S TAF12T
High temperature TC thermometer ©Endress+Hauser

Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries

Measuring points with extremely high process temperatures require these thermometers with ceramic thermowells and special metal thermocouples, such as platinum and rhodium. The thermowell as well as the intermediate and internal sheath of ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.

  • Fördelar

    • Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance

    • Long term stable measurement due to sensor protection with non-porous materials

    • Flexible product selection by modular design

    • Optimized life cycle costs by...

  • Applikationsområde

    • The TAF12T are assemblies with triple ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators.

    • ...

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Thermocouple

  • Characteristic / Application

    metric style

    modular temperature assembly

    high temperature (furnace)

    ncl. triple ceramic thermowell

  • Terminal head

    TA20A - aluminium - cover with screws

    TA20D - aluminium - hinged cover high

    TA30A - E+H, aluminium - cover low - w/o. display

    TA30D - E+H, aluminium - cover high

    DIN A - aluminum

  • Thermowell / protection tube

    ceramic protection tube and 2x inner tube

  • Insert / probe

    ceramic capilarry, rigid

  • Outer diameter protection tube

    24,0 mm (0,94")

    26,0 mm (1,02")

  • Max. immersion length on request

    up to 3.500,00 mm (137,80'')

  • Material protection tube/ thermowell

    Ceramic (C530/C610/C799)

  • Process connection

    compression fitting:

    G11/2"

  • Tip shape

    straight

  • Operating temperature range

    Type S:

    0 C ...1.600 C

    (32 F ...2.912 F)

    Type R:

    0 C ...1.600 C

    (32 F ...2.912 F)

    Type B:

    600 C ...1.700 C

    (1.112 F ...3.092 F)

  • Max. process pressure (static)

    at 20 °C: 1 bar (15 psi)

  • Accuracy

    class 2 acc. to IEC 60584

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Certification

    SIL (transmitter only)

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification
  • C
    • Nr C Order code 60000517

      Stop Flange adjustable,DIN EN 50446,34mm

      Maximum temperature 400 oC Material cast iron. Counter flange and gasket not provided. No gas-tight connection. Dimension: d2=33mm, a=90mm, c=70mm. Clampable diameter from 31mm to 33mm.

    • Order code 60022497

      Compression fitting G1 1/2", 35mm

      Maximum temperature 350 oC. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameters 33/33,4mm. Dimension: A=G 1 1/2", d=35 mm, Wr=55.

    • Order code 71182602

      Spare parts kit sealing TA30A/TA30D

      5x O-ring 3.69x1.78 5x 0-ring 74.7x2.75

    • Order code 71044061

      Fixing kit cpl.TMT82/85/84 (european)

      2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector

  • B
    • Nr B Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed. GL (German Llyod) Marine.

    • Nr B Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, SIL2, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed. GL (German Llyod) Marine.

    • Nr B Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.

    • Nr B Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr B Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

    • Order code TXU10-

      Configuration kit TXU10-

      for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.

    • Order code READWIN-

      Readwin 2000 Operation + Read. software