TLSR2
South African style RTD sensor, cable probe

TLSR2
South African style RTD sensor, cable probe ©Endress+Hauser

Appropriate for all temperature measurement applications where small immersion lengths are needed

Easy installation - with adjustable compression fitting or without process connection - various diameter inserts and customized immersion lengths lead to a high flexibility. The probe is suited to temperature measurement in machinery, laboratory equipment and plants in gaseous or liquid medium like air, water, oil, etc.

Produkten är inte tillgänglig på den svenska marknaden.

  • Fördelar

    • Pt100 measuring element according to IEC 60751 with an accuracy Class A according to IEC 60751 and Band 5 (1/10 DIN)

    • Customized immersion length

    • Sheath material 316SS/L

  • Applikationsområde

    This assembly is specially suited to temperature measurement in machinery, laboratory equipment and experimental plants in gaseous or liquid media like air, water, oils and others.

    It comprises of various diameter fixed inserts with flexible tails. To...

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Resistance Temperature Detector

  • Characteristic / Application

    S.A. Style

    Cable sensor

    universal range of application

    usable with or without a thermowell

  • Thermowell / protection tube

    to use with or without thermowell (can be ordered separately)

  • Insert / probe

    mineral insulated (MI), flexible

  • Max. immersion length on request

    up to 2.000 mm (78,74'')

  • Material protection tube/ thermowell

    1.4401 (316)

  • Optional coating

    Not defined

  • Process connection

    Fixed thread:

    NPT 1/4"

    NPT 1/2"

    G1/4"

    G1/2"

    Adjustable compression fitting:

    NPT 1/8"

    NPT 1/4"

    NPT 3/8"

    NPT 1/2"

    G1/8"

    G1/4"

    G3/8"

    G1/2"

  • Tip shape

    rounded

    flat

  • Operating temperature range

    PT 100:

    -200 ...600 °C

    (-328 ...1.112 °F)

  • Max. process pressure (static)

    at 20 °C: 10 bar (150 psi) without thermowell

  • Accuracy

    class A according to IEC 60751

    Band 5 (1/10 DIN)

  • Response time

    depending on configuration

  • Integration head transmitter

    no

  • Certification

    EN10204 3.1 Material traceability

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification