Omnigrad S TSC140T

Produktbild av: Omnigrad S TSC140T

This product is no longer available.

Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Thermocouple

  • Characteristic / Application

    Steam and gas processes

  • Thermowell / protection tube

    Included, bar stock

  • Insert / probe

    M.I. cable replaceable

  • Process connection

    Weld-in

  • Operating temperature range

    K: -40...800°C
    J: -40...750°C

  • Max. process pressure (static)

    650 bar

  • Accuracy

    Class 2

  • Response time

    t50 = 11.5 s
    t90 = 25 s

  • Integration head transmitter

    PCP 4...20 mA, HART, PROFIBUS-PA

  • Successor

    TC15 avail. March 2004