Vibronic
Point level detection
Liquiphant FTL33

Liquiphant FTL33 ©Endress+Hauser
Liquiphant FTL33 ©Endress+Hauser

Liquiphant, Liquipoint, Cerabar, Ceraphant - A strong team for standard level and pressure applications

Vibronic measuring principle

Liquiphant with permanent function check is the safe choice for point level detection in liquids

Liquiphant FTL33 ©Endress+Hauser
Liquiphant FTL33 ©Endress+Hauser

Point level switch for liquids in compact hygienic design for the food industry

Liquiphant FTL33 is a point level switch for liquids. The FTL33 is especially designed for food & beverage applications where hygienic requirements are requested. The Liquiphant is used for overfill prevention or pump dry-run protection. The IO-Link capability allows easy parameter setting.
Compact:
- Smallest vibronic sensor in the market
Safe:
- Continuous self-monitoring
- Reliable switching independent of media properties
Easy:
- No calibration
- Plug & play
-IO-Link connectivity

  • Fördelar

    • Designed for hygienic applications especially in the food industry - hygienic process connections and approvals available. IO-Link reduces costs and complexity due to easy configuration of the devices via engineering tools

    • CIP and SIP cleanability...

  • Applikationsområde

    Point level switch in compact hygienic design with stainless steel housing for the food industry.

    • Process connections: Threads, hygienic process connections, M24 process adapter

    • Temperature: -40 to +150°C (-40 to +302°F)

    • Pressure: -1 to +40bar (-14.5...

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Vibration Liquids

  • Characteristic / Application

    Point level switch for liquids
    in the food sector

  • Supply / Communication

    20 ... 253V AC/DC, 2-wire
    10 ... 30V DC-PNP, 3-wire

  • Ambient temperature

    40 °C ... 70 °C
    (-40 °F ... 158 °F)

  • Process temperature

    -40 °C ... 150 °C
    (-40 °F ... 302 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum ... 40 bar
    (Vacuum ... 580 psi)

  • Min. density of medium

    >0,7g/cm³
    (>0,5g/cm³ optional)

  • Main wetted parts

    316L

  • Process connection

    Threads:

    G1/2, G3/4, G1, MNPT1/2, MNPT3/4, MNPT1, R1/2, R3/4, R1

  • Process connection hygienic

    Flush mount by use of weld in adapter
    DIN11851
    Tri-Clamp

  • Communication

    AC/DC, DC-PNP

  • Certificates / Approvals

    CSA C/US, EAC

  • Safety approvals

    Overfill prevention WHG

    Leakage

  • Design approvals

    EN 10204-3.1

  • Hygienic approvals

    3A, EHEDG

  • Options

    Switching delay

    Cleaned from oil+grease,

    Surface finish measurement

Dokumentation / manualer / programvara