Radar measurement
Time-of-Flight
Micropilot FMR52

Micropilot FMR52 alu housing with flange ©Endress+Hauser
Micropilot FMR52 alu housing with flange ©Endress+Hauser
Micropilot FMR52 plastic housing with Tri-Clamp ©Endress+Hauser

Time-of-Flight measuring principle

Commissioning movie for Micropilot FMR5x free space radar and Levelflex FMP5x guided radar

Unique HistoROM data management concept for safe level measurement

Continuous adapting algorithms offering safe level measurement due to Multi-Echo Tracking

Micropilot with Advanced Dynamics offering more reliable measuring signals even in the case of turbulences

Micropilot FMR5x with Advanced Diagnostic functions offers foam detection

Micropilot FMR52 alu housing with flange ©Endress+Hauser

For level measurement in aggressive liquids or applications with hygiene requirements

For applications in aggressive liquids Micropilot FMR52 offers extraordinary advantages with its completely PTFE-filled and flush-mounted horn antenna. The FMR52 is also the sensor for hygiene-sensitive applications in the food and life sciences industry - ASME BPE, USP Class VI, 3-A and EHEDG approvals. Micropilot is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

  • Fördelar

    • Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)

    • Reliable non-contact measurement even for changing product and process conditions

    • HistoROM data management concept for fast and easy commissioning, maintenance...

  • Applikationsområde

    Flush-mounted, completely PTFE-encapsulated horn antenna.

    • Process connections: Flush-mounted with cladded flange, process connections for hygiene requirements (Tri-Clamp, 11851)

    • Temperature: -196 to +200°C (-320,8 to +392°F)

    • Pressure: -1 to +25bar (-14...

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Level radar

  • Characteristic / Application

    Premium device for continuous non-contact level measurement, in which aggressive media are used as well as for highest hygiene requirements (ASME BPE, USP Class VI);

    Flush mounted, fully PTFE filled horn antenna

  • Specialities

    Heartbeat Technology,

    SIL 2 according to IEC 61508,

    Bluetooth® commissioning,

    Operation and maintenance SmartBlue App,

    Safety and reliability with Multi-Echo Tracking,

    HistoROM,

    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)

    4-wire (HART)

    Bluetooth® wireless technology and App (optional)

  • Frequency

    K-band (~26 GHz)

  • Accuracy

    +/- 2 mm (0.08 in)

  • Ambient temperature

    -50...+80 °C

    (-58...+176 °F)

  • Process temperature

    -196...+200 °C

    (-321...+392 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum...25 bar

    (Vacuum...363 psi)

  • Main wetted parts

    PTFE

  • Process connection

    Flange:

    DN50...DN150

    ASME 2"...6"

    JIS 10K

  • Process connection hygienic

    Tri-Clamp ISO2852

    DIN11851

  • Application

  • Max. measurement distance

    Standard: 40 m (131 ft)
    With enhanced dynamics: 60 m (197 ft)

  • https://portal.endress.com/picpool/sft/prodcont/technicalinfo/Radar_Mediengruppe_en.jpg https://portal.endress.com/picpool/sft/prodcont/technicalinfo/Radar_not_selected_all_storage tank_storage tank horizontal_FMR52.jpg
  • Communication

    4...20 mA HART

    PROFIBUS PA

    FOUNDATION Fieldbus

    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN 10204-3.1

    ASME B31.3

    AD2000

  • Hygienic approvals

    3A, EHEDG

    CoC ASME-BPE

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV

  • Options

    Display,

    Customized parameterization,

    Remote operation via SmartBlue App using Bluetooth®,

    Gas-tight feed through,

    PWIS free

  • Application limits

    Maximum measuring range is dependent on the tank form and/or application


    Ammoniacal gas phase:

    FMR54 in stilling well

    Strong build-up formation:

    FMR54 with air purge

    Custody transfer measurement:

    FMR5xx

Dokumentation / manualer / programvara