Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Level radar

  • Characteristic / Application

    Highly resistant - easy to clean

  • Supply / Communication

    2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)

  • Frequency

    K-Band (~ 26 GHz)

  • Accuracy

    +/- 3 mm

  • Ambient temperature

    -40 °C...+80 °C
    (-40 °F...+176 °F)

  • Process temperature

    -40° C...+200° C
    (-40 °F...+392 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum...16 bar
    (Vacuum...232 psi)

  • Main wetted parts

    PTFE

  • Process connection

    DN50...DN150

  • Process connection hygienic

    Tri-Clamp ISO2852

    DIN11851

  • Application

  • Max. measurement distance

    Standard: 40m (131ft)

    With additional option F (G): 60m (196ft)

  • https://portal.endress.com/picpool/sft/prodcont/technicalinfo/Radar_Mediengruppe_en.jpg https://portal.endress.com/picpool/sft/prodcont/technicalinfo/Radar_not_selected_FMR245.jpg
  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, IECEx, TIIS, NEPSI

    Overfill prevention WHG

    SIL

    EN 10204-3.1

    Marine GL

    3A, EHEDG

  • Application limits

    Maximum measuring range is dependent on the tank form and/or application


    Ammoniacal gas phase

    FMR230 in stilling well
    Strong buildup formation

    FMR230 with air purge
    Small connections with low DK

    FMR231
    Low DK and high nozzle

    FMR240
    Custody transfer measurement

    FMR5xx

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification
    • Order code 52006628

      Instrument plug M20-M12 "PA" (WDM)150

      4-pin metall plug for installation in the device, providing connection to a T-Box (WDM) or cable socket (WDM). Cable length: 150mm. Not suitable for PROMAG and PROMAG.

  • 20
    • Nr 20 Order code 517391-0011

      Cover F12/T12 Alu, coated, gasket

      Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.

    • Nr 20 Order code 52005936

      Cover F12/T12 Alu, window, gasket

      Material: aluminium. Usage: VU331, housing F12/T12, Micropilot M/S, Prosonic M, Levelflex M.

    • Nr 20 Order code 52018670

      Cover F23 316L, sight glass, gasket

      Material: 316L. Usage: VU331, Levelflex M, Micropilot M.

    • Nr 20 Order code 52018671

      Cover F23 316L, gasket

      Material: 316L. Usage: Levelflex M, Micropilot M.

  • 25
    • Nr 25 Order code 518710-0020

      Cover T3/T12 Alu, coated, gasket

      Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231,FMR240/FMR244/ FMR245, FMR250, FMR530/FMR531/FMR532/ FMR533, FMR540, FMU40/FMU41/FMU42.

  • 11
    • Nr 11 Order code 52005643

      Hood housing T12

      Cable compartment, electronics side. Usage: Micropilot M/S, Prosonic M, Levelflex M.

    • Nr 11 Order code 52006026

      Cover terminal compartment F12/F23

      Hood terminal compartment. Usage: Micropilot M, Prosonic M, Levelflex M.

    • Nr 11 Order code 52019062

      Cover terminal compartment F12/F23,FHX40

      Hood terminal compartment. Usage: separate display, Micropilot M, Prosonic M, Levelflex M.

    • Order code 71092209

      O-ring 113.9x3.63 EPDM, 5 pieces

      Usage: cover T12/F12/F23.

    • Order code 543199-0001

      Protective cover for housing T12/F12, SS

      Usage: Micropilot M, Micropilot S, Prosonic M, Levelflex M. Material: 316Ti.

  • 35
    • Nr 35 Order code 52006197

      Terminal module 4-pole, HART, 2-wire

      Cable connection. Usage: housing F12/F23, Micropilot M, Levelflex M, Prosonic M.

    • Nr 35 Order code 52012156

      Terminal module 4-pole, PA, FF

      PROFIBUS PA, FOUNDATION Fieldbus. Usage: Micropilot II/M, Prosonic M, Levelflex M.

    • Nr 35 Order code 52013302

      Terminal mod. Ex d, 4-pol., 2wr,HART,T12

      Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.

    • Nr 35 Order code 52013303

      Terminal mod. Ex d, 2-pol.,2wr,PA/FF,T12

      2-wire, PROFIBUS PA/FOUNDATION Fieldbus. Ex d limiter. Usage: housing T12, Levelflex M, Micropilot M, Prosonic M.

    • Nr 35 Order code 52014817

      Terminal mod4-pole,HART,ferrit,F12/F23

      GL/ABS marine certificate. Usage: Micropilot M, Levelflex M.

    • Nr 35 Order code 52014818

      Terminal mod.4-p.,PA/FF,ferrit,F12/F23

      GL/ABS marine certificate. Usage: Micropilot M, Levelflex M.

    • Nr 35 Order code 52018949

      Terminal mod. 4-pol.,EEx ia,HART,T12,OVP

      4-pole, 2-wire. OVP = overvoltage protection. Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.

    • Nr 35 Order code 52018950

      Terminal mod. 2-p.,EEx ia,PA/FF,T12,OVP

      2-pole, 2-wire. PROFIBUS PA, FOUNDATION Fieldbus. OVP = overvoltage protection. Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.

  • 31
    • Nr 31 Order code 52024953

      HF-module FMR24x, FMR250, 26GHz

      Version uP III.3. Usage: electronics from software version 1.0, FMR250. Electronics from software version 5.0, FMR240/FMR244/FMR245, advanced dynamics.

    • Nr 31 Order code 71026572

      HF module FMR24x, 26GHz, v5.0

      Version uP III.5. Usage: electronics from software version 5.0, FMR240/FMR244/FMR245.

  • 30
    • Nr 30 Order code 71023757

      Electronics FMR23x/FMR24x,Ex,HART,v4.0

      Version 4.0. Usage: FMR230/FMR231, FMR240/FMR244/FMR245.

    • Nr 30 Order code 71023758

      Electronics FMR23x/FMR24x, Ex,PA,v4.0

      PROFIBUS PA, version 4.0. Usage: FMR230/FMR231, FMR240/FMR244/FMR245.

    • Nr 30 Order code 71023759

      Electronics FMR23x/FMR24x, Ex,FF,v4.0

      FOUNDATION Fieldbus, version 4.0. Usage: FMR230/FMR231, FMR240/FMR244/FMR245 with HF module, version uP III.2.

    • Nr 30 Order code 71026754

      Electronics FMR24x/250, Ex, HART,v5.0

      HART, version 5.0. Usage: FMR240/FMR244/FMR245, FMR250.

    • Nr 30 Order code 71026819

      Electronics FMR24x/250, Ex, PA, v5.0

      PROFIBUS PA, version 5.0. Usage: FMR240/FMR244/FMR245, FMR250.

    • Nr 30 Order code 71026820

      Electronics FMR24x/250, Ex, FF, v5.0

      FOUNDATION Fieldbus, version 5.0. Usage: FMR240/FMR244/FMR245, FMR250.

  • 40
    • Nr 40 Order code 52026443

      Display VU331, version 2

      Alphanumeric display, 4-line. Usage: FMR530/532/533, FMR540, FMU40/41/42/43/44.

    • Order code FHX40-

      Display FHX40

      Remote display + local operation. 4-line LC-display. :: Menu driven plain text operation. :: Easy setup. :: User language selectable. :: Envelope curve display on site. Usage: FMG60, FMU40/FMU41/FMU42/FMU43/FMU44.

  • 50
    • Nr 50 Order code FMR245X-

      Antenna FMR245, process connection

      Small horn antenna, PTFE clad. Usage: FMR245.

    • Order code 52013874

      Mounting bracket FHX40 1" / 2" pipe

      Usage: FHX40.

    • Order code 52016334

      Cable FHX40, 20m

      Connection cable, doubled shielded. Usage: FHX40.

    • Order code 71020502

      Cable FHX40, 5m

      Connection cable, doubled shielded. Usage: FHX40.

    • Order code 71020503

      Cable FHX40, 10m

      Connection cable, doubled shielded. Usage: FHX40.

    • Order code 71020504

      Cable FHX40, 30m

      Connection cable, doubled shielded. Usage: FHX40.

    • Order code 71007843

      ToF Adapter FXA291

      Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.

    • Order code 71067434

      Modification name plate, non Ex

      Blank. To fill in the new order code when a non Ex instrument has been modified. Usage: FMB50/FMB51/FMB52, FMR230/FMR231, FMR240/FMR244/FMR245, FMR250,FMR530/FMR532,FTL50/FTL50H/FTL51/ FTL51C/FTL51H, FTL70/FTL71, FTL80/FTL81/ FTL85, NMR81, PMC51, PMC71, PMP51/PMP55.

    • Order code

      Phase out spares

    • Order code
  • Ersättare