Hydrostatic
Level measurement
Deltapilot FMB70

Deltapilot FMB70 hygienic housing ©Endress+Hauser
Deltapilot FMB70 aluminum housing ©Endress+Hauser
Deltapilot FMB70 separate housing ©Endress+Hauser
Deltapilot FMB70 separate housing hygienic ©Endress+Hauser

Pressure measuring principle

Deltapilot FMB70 ©Endress+Hauser

Highest performance pressure sensor with the Contite cell for hydrostatic level measurement

The Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM/M-DAT data module makes management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety systems.

  • Fördelar

    • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.1%, optionally ±0.075% and minimum temperature effects thanks to active temperature compensation

    • Best batch-to-batch repeatability and long-term stability

    • ...

  • Applikationsområde

    For level and/or pressure measurement.

    • Process connections: Threads, flanges and hygienic connections

    • Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)

    • Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)

    • Accuracy: ±0.075%

    • International...

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Hydrostatic

  • Characteristic

    Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
    - hermetically welded
    - absolute condensation tight
    - climate-resitant
    - long-term stable
    - Lowest temperature influences

    Compact version
    Modular Deviceplatform

  • Supply voltage

    4...20 mA HART

    10,5...45 VDC (Non Ex):

    Ex ia: 10,5...30 VDC

    PROFIBUS PA:

    9...32 VDC (Non Ex)

    FOUNDATION Fieldbus:

    9...32 VDC (Non Ex)

  • Reference Accuracy

    Standard 0,1%
    Optional 0,075%

  • Long term stability

    0,05% of URL/year

  • Process temperature

    -10°C...100°C
    (14°F...212°F)

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Measuring cell

    100 mbar...10 bar
    (1.5 psi...150 psi)

  • Smallest calibratable span

    25 mbar (3.63 psi)

  • Vacuum resistance

    0 mbar abs.

  • Max. overpressure limit

    40 bar (600 psi)

  • Process connection

    Thread:

    G1 1/2, MNPT1/2

    Flange:

    DN40...DN100,

    ASME 1 1/2"...4",

    JIS 10K

  • Process connection hygienic

    Tri-Clamp

    DIN11851

    DIN11864-1

    NEUMO

    Varivent N

    SMS

    DRD

  • Material process membrane

    316L, AlloyC,

    Gold-Rhodium

  • Material gasket

    None, measuring cell welded

  • Fill fluid

    Inert oil,

    Synthetic oil

  • Material housing

    316L, Die-cast aluminum

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN10204-3.1

    NACE MR0175
    MR0103

  • Hygienic approvals

    3A, EHEDG

    CoC ASME-BPE

  • Marine approvals

    GL, DNV

  • Drinking water approvals

    NSF

  • Specialities

    Gold-rhodium coated membrane

  • Mätprincip

    Hydrostatic

  • Characteristic / Application

    Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
    - hermetically welded
    - absolute condensation tight
    - climate-resitant
    - long-term stable
    - Lowest temperature influences

    Compact version
    Modular Deviceplatform

  • Specialities

    Diagnostic functions

  • Supply / Communication

    4...20mA HART:
    10,5...45V DC
    Ex ia: 10,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC (Non Ex)

  • Accuracy

    Standard 0,1%
    Optional 0,075%

  • Long term stability

    0,05% of URL/year

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Process temperature

    -10°C...100°C
    (14°F...212°F)

  • Process pressure absolute / max. overpressure limit

    40 bar (600 psi)

  • Pressure measuring range

    100mbar...10bar
    (1.5psi...150psi)

  • Main wetted parts

    Alloy C
    316L

  • Process connection

    Thread:

    G1 1/2, MNPT1/2

    Flange:

    DN40...DN100,

    ASME 1 1/2"...4",

    JIS 10K

  • Process connection hygienic

    Tri-Clamp

    DIN11851

    DIN11864-1

    NEUMO

    Varivent N

    SMS

    DRD

  • Max. measurement distance

    100m (328ft) H2O

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN10204-3.1

    NACE MR0175, MR0103

  • Hygienic approvals

    3A, EHEDG

    CoC ASME-BPE

  • Marine approval

    GL/ DNV

  • Drinking water approvals

    NSF

  • Options

    HistoROM/M-Dat
    4-line digital display
    SS- or Aluminiumhousing

    Separate housing

  • Application limits

    Measuring cell: Contite,
    condensate-proof, watertight,
    metal welded

    If pressurized, possibly use
    differential pressure measurement
    with two pressure
    transmitters. Observe ratio
    head pressure : hydrostatic
    pressure

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification
  • 12
    • Nr 12 Order code 52020440

      Mounting set housing T14/T15 / sensor

      Consists of: 2x O-ring 45.69x2.62 EPDM. Retaining ring, plastics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 12 Order code 71020596

      Mounting set housing T17 / sensor

      Consists of: 2x O-ring 45.62x69x2.62 EPDM. 1x profile gasket 51.4x57.2x1.6 EPDM. Retaining ring, plastics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 13
    • Nr 13 Order code 52022418

      Push button housing, PA/FF

      Consists of: push button, cover + screws. Usage: external operation, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 13 Order code 52024110

      Push button housing, HART, version 2

      Consists of: push button, cover + screws. Colour dark grey. Usage: external operation, FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75.

  • 15
    • Nr 15 Order code 52020760

      Cable gland M20, gasket

      Consists of: cable gland M20. O-ring 18.72x2.62 VMQ. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 15 Order code 52020761

      Cable entry G1/2, gasket, adapter

      Consists of: gasket 18.72x2.51 NBR. Adapter M20 > G1/2. O-ring 18.77x1.78 NBR. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 15 Order code 52020762

      Plug 2/7-pole, HAN7D, gasket

      Consists of: harting plug set. Usage: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Nr 15 Order code 52020763

      Plug 3-pole, M12, gasket

      Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Order code 52006263

      Socket for plug 4p-125V, 4A-M12

      M12 socket for plug. Self confectionery connection. Usage: plug M12.

    • Order code 71043576

      Housing filter plastic T15, 3 pieces

      Consists of: filter plug, Gore-Tex filter. Usage: housing T15, FMB70.

    • Order code 71111056

      Housing filter VA,EPDM,F15/31/T14/17,1pc

      Consists of: vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: housing T14, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Housing F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55. Housing F15 w/o B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

    • Order code 71219639

      Housing filter VA, VMQ, F15, T17, 1 pc.

      Consists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 bei B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

  • 20
    • Nr 20 Order code 52020432

      Cover T14/T15 Alu, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 71002774

      Cover T17 316L, gasket

      Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 25
    • Nr 25 Order code 71002774

      Cover T17 316L, gasket

      Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 20
    • Nr 20 Order code 71002810

      Cover T17 316L, sight glass, gasket

      Material: 316L. Sight glass: mineral glass. Flat gasket EPDM, centering ring, screw. For approval 2,3,4,7,8,Q,W. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval BC,BD,IB. Usage: FMD71/FMD72.

    • Nr 20 Order code 71002811

      Cover T17 316L, sight glass PC, gasket

      Material: 316L. Sight glass: Polycarbonate PC. Flat gasket EPDM, centering ring, screw. For approval A,E,F,H,I,R,S,U,1,6. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval AA,BA,CA,CB,CC,CD,FA,FB, FD,IA. Usage: FMD71/FMD72.

    • Nr 20 Order code 71245247

      Cover T14/T15 Alu, sight glass, gasket

      Material: aluminium, coated. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 21
    • Nr 21 Order code 52020429

      Sealing EPDM, F30/31/34, T14/15, 5 pcs.

      Consists of: 5x O-ring 75.87x2.62, EPDM, PTFE, FDA. Usage: housing F30/F31/F34, T14/T15.

    • Order code 71290825

      Ground terminal T14/T15/T17, F30/F31

      Consists of: spring washer, screw, earth handle, clamp. Usage: housing T14/T15/T17, FMB70, FMD71/FMD72/ FMD77/FMD78, PMC71, PMP71/PMP75, PMD70/PMD75. Housing F30/F31, FMB50/FMB51/FMB52/ FMB53, PMC51, PMD55, PMP51/PMP55.

  • 25
    • Nr 25 Order code 52020432

      Cover T14/T15 Alu, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 30
    • Nr 30 Order code 71026358

      Electronics HART Ex, v2.10

      4-20mA, version 02.10.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71026359

      Electronics HART Ex, ext. p. b., v2.10

      4-20mA, version 02.10.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071824

      Electronics PA, HW02.00, SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071825

      Electronics PA, ext. p.b., HW02.00,SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071826

      Electronics FF, HW2.00, SW3.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on electronics. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071827

      Electronics FF, ext. p.b., HW2.00,SW3.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on housing. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71196092

      Electronic HART Ex, v2.11

      4-20mA, version 02.11.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71196093

      Electronics HART Ex, ext. p. b., v2.11

      4-20mA, version 2.11.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71214890

      Electronics FF, ext. p.b.,HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.

    • Nr 30 Order code 71214892

      Electronics FF, HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.

    • Nr 30 Order code 71263933

      Electronics HART Ex, v2.20

      4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on electronics. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71263934

      Electronics HART Ex, ext. p. b., v2.20

      4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on housing. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71386147

      Elektronics HART Ex, v2.30

      4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on electronics. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71386153

      Electronics HART Ex, ext. p. b., v2.30

      4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on housing. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

  • 31
    • Nr 31 Order code 52027785

      HistoROM / M-DAT, 16K

      Setup-/diagnostic software included. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 31 Order code 52027785

      HistoROM / M-DAT, 16K

      Setup-/diagnostic software included. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 35
    • Nr 35 Order code 52020434

      Terminal 3-pole, RFI, HART, TIIS

      RFI-filter. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75, TIIS Ex ia.

    • Nr 35 Order code 52026605

      Terminal 2-pole, RFI, PA, TIIS

      RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75. TIIS Ex ia, TIIS Ex d. PMC71, TIIS Ex ia.

    • Nr 35 Order code 52027691

      Terminal 2-pole, RFI, FF, Ex

      RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71028473

      Terminal 3p., RFI, HART, OVP, TIIS

      Overvoltage protection, RFI-filter. Usage: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71028475

      Terminal 2-pole, RFI, PA, OVP, Ex

      Overvoltage protection, RFI-filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71028476

      Terminal 2-pole, RFI, FF, OVP, Ex

      Overvoltage protection, RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71121574

      Terminal 2-pole, RFI, PA, Ex

      RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for TIIS.

    • Nr 35 Order code 71191892

      Terminal 3-pole,Li=0, RFI,HART,Ex ia/Exd

      RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71191894

      Termin.3-p.,Li=0,RFI,HART,OVP,Ex ia/Exd

      Overvoltage protection, RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 40
    • Nr 40 Order code 71002865

      Display module VU340, Cbar/Dbar/Dpilot S

      Digital display, 3 push buttons, snapped bracket. Languages DE/EN/FR/ES/IT/NL, from software version 02.00.zz; Usage: electronics HART. Languages DE/EN/FR/ES/IT/NL/JA/ZH. From software version 02.01.zz; Electronics HART. Languages DE/EN/FR/ES/IT/JA/ZH/RU, from software version 02.11.zz; Electronics HART. From software version 04.00.zz; Electronics PROFIBUS PA. From software version 03.00.zz; Electronics FOUNDATION Fieldbus, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75. From software version 01.00.zz; Electronics HART, FMD71/FMD72.

    • Order code 71043886

      Cable PE, L=2m/80inch, separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 71043888

      Cable PE, L=5m/200inch, separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 71043889

      Cable PE, L=10m/400inch,separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 71070738

      Cable FEP, L=5m/200inch,separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 214880-0002

      Weld-in adapter UNI D65, 316L

      Flush mount process connection. Core hole: 65mm. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52, PMC51, PMP23, PMP55, PMP75.

    • Order code 52002041

      Weld-in adapter DRD DN50, 316L

      Front-flush mounting of devices with DRD flange. Material: 316L. Seal: PTFE flat. FDA compliant. Usage: FMB50, FMB70, FMD78, FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMC71, PMP51/PMP55, PMP75.

    • Order code 52006262

      Weld-in adapter UNI D85, 316L

      Flush mount process connection. Core hole: 85mm. Material: 316L. Seal: silicone profile gasket. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52 PMC51, PMP23, PMP55, PMP75.

    • Order code 52010173

      Weld-in adapter UNI D85, 316L, 3.1

      Flush mount process connection. Core hole: 85mm. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52, PMC51, PMP23, PMP55, PMP75.

    • Order code 52010174

      Weld-in adapter UNI D65, 316L, 3.1

      Flush mount process connection. Core hole: 65mm. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52, PMC51, PMP23, PMP55, PMP75.

    • Order code 52011899

      Weld-in adapter DRD DN50, 316L, 3.1

      Flush mount process connection of devices with DRD flange. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: PTFE flat. FDA compliant. Usage: FMB50, FMB70, FMD78, FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMC71, PMP51/PMP55, PMP75.

    • Order code 52024469

      Weld-in adapter G1-1/2, 316L

      Mounting process connection G1-1/2. Material: 316L. Correct installation only with dummy. Usage: FMB50/FMB51/FMB52, FMB70, PMC51, PMC71, PMP51/PMP55, PMP71/PMP75.

    • Order code 52024470

      Weld-in adapter G1-1/2, 316L, 3.1

      Mounting process connection G1-1/2. Material: 316L. Inspection cert. EN10204-3.1 material. Usage: FMB50/FMB51/FMB52, FMB70, PMC51, PMC71, PMP51/PMP52, PMP71/PMP75.

    • Order code 916743-0000

      Weld-in adapter DRD DN50, 304

      Flush mount process connection. Material: 304. Seal: PTFE flat. FDA compliant. Usage: Flush mount FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMP51, PMP55, PMC71, PMP75, FMB50, FMB70, FMD78.

  • 50
    • Order code 52024228

      Flat seal 50x65x1 PTFE, FDA, 5 pieces

      Fit to weld-in adapter DRD-DN50. Flush mount FTL50H/FTL51H, PMC51, pressure device.

  • 57
    • Nr 57 Order code 52023572

      Profile gasket silicone, 5 pieces

      Process gasket universal process adapt. FDA listed. Usage: FMB50, FMB70, FMI51/FMI52, FTI51/FTI52/FTI55, PMC51.

    • Nr 57 Order code 71100719

      Profile gasket EPDM, 5 pieces

      Process gasket universal adapter. Usage: FMB50, FMB70, PMC51, PMP23.

    • Order code 71114172

      Adapter UNI, DIN11851 DN40, 316L

      Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114173

      Adapter UNI, DIN11851 DN50, 316L

      Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114174

      Adapter UNI, DRD DN50, 65mm, 316L

      Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114177

      Adapter UNI, Varivent N, 316L

      Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114178

      Adapter UNI, DIN11851 DN40, 316L, 3.1

      Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114205

      Adapter UNI, DIN11851 DN50, 316L, 3.1

      Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114206

      Adapter UNI, DRD DN50, 65mm, 316L, 3.1

      Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114208

      Adapter UNI, Varivent N, 316L, 3.1

      Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50_110_UNJ/UPJ, PMC51_110_UNJ/UPJ.

    • Order code 52024471

      Weld-in dummy, adapter G1-1/2

      Material: brass. To avoid any deformation of the adapters 52024469 / 52024470 during welding.

    • Order code 71114176

      Adapter UNI, Clamp 2", 316L

      Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114178

      Adapter UNI, DIN11851 DN40, 316L, 3.1

      Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114207

      Adapter UNI, Clamp 2", 316L, 3.1

      Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114160

      Weld-in adapter UNI 6" D85, 316L

      Flush mount process connection. Core hole: 85mm. Material: 316L. Seal: silicone profile gasket FDA conform. Usage: FMB50, FMB70.

    • Order code 71114171

      Weld-in adapter UNI 6" D85, 316L 3.1

      Flush mount process connection. Core hole: 85mm. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket FDA conform. Usage: FMB50, FMB70.

    • Order code 71304770

      Mountingset, housing T14, special

      Material: 316L. Usage: mounting kit to attach the own mounting bracket / weather protection cover, FMB70, PMC71, PMP71/PMP75.

    • Order code 71102216

      Mountingset Cerabar,Deltapilot,Levelflex

      Material: 316L. Usage: wall/pipe mounting (2"), FMB50/FMB51/FMB52/FMB53, FMB70, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, PMC51, PMC71, PMP51/PMP55, PMP71/PMP75.

    • Order code XPRFID-

      Spare RFID TAG