En överblick över specifikationer
-
Accuracy
+/- 3 mm or +/- 0.2 % of set measuring range
-
Process temperature
-20 °C...+60 °C
(-4 °F...+140 °F) -
Process pressure / max. overpressure limit
0.7 bar...3 bar abs
(10 psi ...44 psi) -
Max. measurement distance
Sensor 1-1/2": 2 m (6.6 ft)
Sensor 2": 3.5 m (11 ft) -
Main wetted parts
PP/EPDM
Applikationsområde
The range of applications extends from monitoring levels in sewage treatment plants and process water tanks to applications for loading, storage and buffer tanks. FMU30 ultrasonic sensor offers proven software algorithms and all warning and alarm messages are shown on the four-line plain text display and guarantee fast remedy of problems. The envelope curve can also be shown on the display. As the analysis results are displayed directly on-site, this ensures quick and accurate error diagnostics.
Two-wire instrument for continuous non-contact level and flow measurement.
Process connection: Thread
Temperature: -20 to +60°C (-4 to +140°F)
Pressure: +0.7 to +3bar (+10 to +44psi)
Maximum measuring distance:
Sensor 1½" for liquids 5m (16ft) and for bulk solids 2m (6.6ft),
Sensor 2" for liquids 8m (26ft)and for bulk solids 3.5m (11ft)Blocking distance:
Sensor 1½" 0.25m (0.8ft),
Sensor 2" 0.35m (1.15ft)International explosion protection certificates
Fördelar
Quick and simple commissioning via menu-guided onsite operation with four-line plain text display, 7 languages selectable
Envelope curves on the on-site display for simple diagnosis
Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate
Non-contact measurement method minimizes service requirements
Installation possible from thread G 1½ or 1½ NPT upwards
Integrated temperature sensor for automatic correction of the temperature dependent sound velocity
Videor
Fundamental urvalet
-
Enkla produkter
- Enkla att välja, installera och använda
Tekniska egenskaper
Enkelhet
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
Föregångare
-
-
Användarinstruktion (BA)
Prosonic T FMU30
Engelsk version - 02/2014
Compact transmitters for non-contact level measurements of fluids, pastes and coarse bulk materials
EN SV 14/02/201404/04/201216/02/2010Språk:
Engelska
Version:
14/02/2014
Filstorlek:
3.2 MB
Filnamn:
BA00388FEN_1414.pdf
-
-
-
Teknisk information (TI)
Ultrasonic Level Measurement
Engelsk version - 02/2014
Compact transmitters for non-contact level measurement of fluids, pastes and coarse bulk materials
EN SV 14/02/201416/01/201331/03/201116/02/2010Språk:
Engelska
Version:
14/02/2014
Filstorlek:
2.1 MB
Filnamn:
TI00440FEN_1514.pdf
-
-
-
Teknisk information (TI)
Ultrasonic Level Measurement
Compact transmitters for non-contact level measurement of fluids, pastes
and coarse bulk materialsEN SV 14/02/201416/01/201331/03/201116/02/2010Språk:
Engelska
Version:
14/02/2014
Filstorlek:
2.1 MB
Filnamn:
TI00440FEN_1514.pdf
-
-
-
Användarinstruktion (BA)
Prosonic T FMU30
Compact transmitters for non-contact level measurements of fluids,
pastes and coarse bulk materialsEN SV 14/02/201404/04/201216/02/2010Språk:
Engelska
Version:
14/02/2014
Filstorlek:
3 MB
Filnamn:
BA00387FEN_1414.pdf
-
-
-
Användarinstruktion (BA)
Prosonic T FMU30
Compact transmitters for non-contact level measurements of fluids,
pastes and coarse bulk materialsEN SV 14/02/201404/04/201216/02/2010Språk:
Engelska
Version:
14/02/2014
Filstorlek:
3.2 MB
Filnamn:
BA00388FEN_1414.pdf
-
-
-
Kortfattad instruktion (KA)
Korta användarinstruktioner Prosonic T FMU30 Ultraljudsnivåmätning
Korta användarinstruktioner
Prosonic T FMU30
UltraljudsnivåmätningEN SV 14/02/201404/11/201108/09/201116/02/2010Språk:
Svenska
Version:
14/02/2014
Filstorlek:
1.5 MB
Filnamn:
KA01054FSV_1514.pdf
-
-
-
Kortfattad instruktion (KA)
KA Prosonic T FMU30
Mätteknik med ultraljud
EN SV 01/12/2022Språk:
Svenska
Version:
01/12/2022
Filstorlek:
485.6 KB
Filnamn:
KA01638FSV_0122-00.pdf
-
-
-
Kortfattad instruktion (KA)
Ultrasonic Level Measurement
Prosonic T FMU30
EN SV 16/02/2010Språk:
Engelska
Version:
16/02/2010
Filstorlek:
138.6 KB
Filnamn:
KA290FA2_1209.pdf
-
-
-
Installationsanvisningar (EA)
Sensor for FMU30 Installation instruction
Prosonic T FMU30
EN SV 12/04/2012Språk:
Engelska
Version:
12/04/2012
Filstorlek:
261.6 KB
Filnamn:
EA0032FA2_0210.pdf
-
-
-
Installationsanvisningar (EA)
Electronics for FMU30 Installation instruction
Prosonic T FMU30 - exchange of electronics
EN SV 12/04/2012Språk:
Engelska
Version:
12/04/2012
Filstorlek:
210 KB
Filnamn:
EA0030FA2_0210.pdf
-
-
-
Installationsanvisningar (EA)
Display for FMU30 Installation instruction
Prosonic T FMU30
EN SV 12/04/2012Språk:
Engelska
Version:
12/04/2012
Filstorlek:
164.8 KB
Filnamn:
EA0031FA2_0210.pdf
-
-
-
Ex-säkerhetsinstruktion (XA)
Safety Instructions Prosonic T FMU30
Ex ia Class I, Division 1, Group A-D, T5
Class I, Zone 0, AEx/Ex ia IIC T5 GaSpråk:
Engelska
Version:
26/06/2013
Filstorlek:
153.9 KB
Filnamn:
XA01080FEN_0112.pdf
-