Microwave barrier receiver
Soliwave FDR57

Soliwave FDR57 ©Endress+Hauser
Soliwave FDR57 ©Endress+Hauser

Transceiver for non-contact point level detection and bulk flow monitoring

The Soliwave microwave barrier uses a non-contact procedure for detection of point levels and bulk flow (flow / no flow, trend). The device is also suitable for detecting and counting objects, detection of deposits as well as monitoring of filling processes and material transfer points. It can be installed in containers, conduits, hoppers, filling stations, shafts, filters or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside.

  • Enkla produkter

  • Enkla att välja, installera och använda

Tekniska egenskaper

Enkelhet

  • Standardprodukter

  • Pålitliga, robusta och lätta att underhålla

Tekniska egenskaper

Enkelhet

  • High-end produkter

  • Mycket funktionella och praktiska

Tekniska egenskaper

Enkelhet

  • Specialprodukter

  • Designade för krävande applikationer

Tekniska egenskaper

Enkelhet

Varierande

FLEX urvalet Tekniska egenskaper Enkelhet
  • F
  • L
  • E
  • X

Fundamental urvalet

Möt dina grundläggande mätbehov

Tekniska egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Lean urvalet

Hantera dina kärnprocesser med enkelhet

Tekniska egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Extended urvalet

Optimera dina processer med innovativa teknologier

Tekniska egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Xpert urvalet

Hantera dina mest utmanande applikationer

Tekniska egenskaper
Enkelhet

Varierande

  • En överblick över specifikationer

    • Process temperature

      Non-contact installation: any

      Within installation:
      -40 °C ... +70 °C
      (-40 °F ... +158 °F)

      With HT-Adapter:
      up to +450 °C (+842 °F)

    • Process pressure absolute / max. overpressure limit

      Non-contact installation: any

      Within installation:
      0.5 bar ... 6.8 bar
      (7.2 psi ... 99 psi) abs.

      With HD-Adapter:
      up to +21 bar (+305 psi) abs.

    • Min. density of medium

      Solid weight: > 10 g/l

Snabbval

Välj från de föreslagna alternativen
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

eller

Individuell konfigurering

Fortsätt välja från alla tillgängliga alternativ
  • Fördelar

    • Simple assembly with R 1½, 1½ NPT thread or G 1½ (with lock nut)

    • Mechanically robust construction ensures cost savings over the whole life cycle of the product: No wear and tear, process-wetted ceramic sensor diaphragm (optional), long serviceable life...

  • Applikationsområde

    Non-contact (wear- and maintenance-free) limit detection (min/max) and flow monitoring (flow/no flow, trend) for bulk solids.

    • Detecting, counting and positioning of objects

    • Detection and analysis of deposits and contamination in filters

    • Monitoring of...

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Microwave barrier

  • Characteristic / Application

    Transceiver

    Non-contact point level detection and flow monitoring

    Detecting, counting and positioning of objects

    Monitoring of material transfer points

    Detection and analysis of deposits and contamination


    Installation:
    Non-contact installation (tranmission window) or front-flush installation (contact)

  • Specialities

    With optional integrated bulk flow monitoring

    Parallel mode with up to 5 channels

    Detection range limit: max. 100 m

    Detection range flow: max. 10 m, depending on bulk solids

  • Supply / Communication

    Via process transmitter with control unit Nivotester FTR525

  • Ambient temperature

    -40 °C...+70 °C

    (-40 °F...+158 °F)

  • Process temperature

    Non-contact installation: any


    Within installation:

    -40 °C ... +70 °C

    (-40 °F ... +158 °F)


    With HT-Adapter:

    up to +450 °C (+842 °F)

  • Process pressure absolute / max. overpressure limit

    Non-contact installation: any


    Within installation:

    0.5 bar ... 6.8 bar

    (7.2 psi ... 99 psi) abs.


    With HD-Adapter:

    up to +21 bar (+305 psi) abs.

  • Min. density of medium

    Solid weight: > 10 g/l

  • Main wetted parts

    Non-contact installation:

    no wetted parts


    Within installation:

    316Ti, PTFE or Ceramic

  • Process connection

    Threads:

    1-1/2" R, 1-1/2" G, 1-1/2" NPT

  • Communication

    Via process transmitter with control unit Nivotester FTR525

  • Certificates / Approvals

    ATEX, CSA C/US, IEC Ex

  • Design approvals

    EN10204-3.1

  • Options

    Sight glass

    High temperature adapter

    High pressure adapter

    Installation bracket

    FAR50, FAR51, FAR52, FAR53, FAR54, FAR55

  • Components

    Transmitter: FQR57

    Process transmitter: FTR525

  • Application limits

    Solid weight: < 10 g/l

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification