En överblick över specifikationer
-
Measurement range
-1500mV to +1500mV
-
Process temperature
0 to 80 °C (32 to 170 °F)
-
Process pressure
1 to 10 bar abs at 80 °C
(15 to 145 psi abs at 176 °F)
Applikationsområde
Orbipac CPF82D is the digital simple solution for ORP measurement in harsh environments. Its large, dirt-repellent PTFE diaphragm guarantees low maintenance while its integrated assembly saves space and time during flow or immersion installation. Orbipac CPF82D is not the latest Memosens generation. To get information on the new Memosens CPF82E sensor with extended functionality, click here.
Orbipac CPF82D is the robust ORP sensor for treatment of industrial water and wastewater and for processes in mining industries. It monitors:
Inlet and outlet
Neutralization
Flotation
Leaching
Fördelar
Suitable for flow and immersion installation
Long-time stable: Second electrolyte bridge for better protection against electrode poisoning ions such as S2- or CN- ions
Robust polymer housing protects against mechanical damage
Maximum process safety through non-contact inductive signal transmission
Enables predictive maintenance due to storage of sensor and process-specific data
Reduced operating costs thanks to minimized process downtime and extended sensor lifetime
Videor
Extended urvalet
-
High-end produkter
- Mycket funktionella och praktiska
Tekniska egenskaper
Enkelhet
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
-
-
Teknisk information (TI)
Orbipac CPF81D/CPF82D and CPF81/CPF82
pH/ORP sensors, with digital Memosens technology or analog
For mining operations, industrial water and wastewater treatmentEN SV 15/07/202004/06/202030/11/201401/07/200801/03/2004Språk:
Engelska
Version:
15/07/2020
Filstorlek:
499.2 KB
Filnamn:
TI00191CEN_1520.pdf
-
-
-
Användarinstruktion (BA)
pH-/redoxsensorer och referenshalvceller
Sensorer med Memosens-teknik och analoga sensorer
EN SV 04/05/202031/12/201730/11/2015Språk:
Svenska
Version:
04/05/2020
Filstorlek:
1.1 MB
Filnamn:
BA01572CSV_0320.pdf
-
-
-
EU-försäkran
Product family: CeraGel, CeraLiquid, Ceramax, ConduMax H, ConduMax W, InduMax H, InduMax P, Liquiline, Memosens, Messkabel, Orbi Pac, OrbiPore, OrbiSint, OxyMax H, OxyMax W, TopHit
Product root: CLS15D-, CLS16D-, CLS21D-, CLS50D-, CLS54D-, CLS82D-,
CML18-, COS21D-, COS22D-, COS51D-, COS81D-, CPF82D-, CPL51E-
,
CPS11D-, CPS12D-, CPS16D-, CPS171D-, CPS31D-, CPS341D-, CPS41D-,
CPS42D-, CPS441D-, CPS471D-, CPS47D-, CPS491D-, CPS71D-,
CPS72D-,
CPS77D-, CPS91D-, CPS92D-, CPS96D-, CPS97D-, CYK10-, CYK20-
Declaration number: EC_00828_02.20EN SV 14/02/2022Språk:
Engelska
Version:
14/02/2022
Filstorlek:
281.9 KB
Filnamn:
EC_00828_03.22_D-Sensoren CML18 EMV_RoHS.pdf
-
-
-
EU-försäkran
Product family: Messkabel, OrbiPac
Product root: CPF81D-, CPF82D-, CYK10-, CYK20-
Declaration number: EC_00657_03.24EN SV 06/01/2023Språk:
Engelska
Version:
06/01/2023
Filstorlek:
63.9 KB
Filnamn:
EC_00657_03.23_CPF8xD_nonEx unterschrieben.pdf
-
-
-
Försäkran om överensstämmelse i Storbritannien
Product family: OrbiPac
Product root: CPF81D-, CPF82D-
Declaration number: UK_00374_01.21Språk:
Engelska
Version:
04/08/2021
Filstorlek:
94.6 KB
Filnamn:
UK_00374_01.21 CPF8xD_nonEx.pdf
-
-
-
Explosionsskydd
Product family: InduMax P, Liquiline M, Memosens
Product root: CLS12-, CLS13-, CLS15-, CLS15D-, CLS16-, CLS16D-,
CLS21-, CLS21D-, CLS50-, CLS50D-, CLS82D-, CM42-, COS21D-, COS22D-,
COS51D-, CPF81-, CPF81D-, CPF82-, CPF82D-, CPS11-, CPS11D-, CPS12-,
CPS12D-, CPS13-, CPS16D-, CPS171D-, CPS41-, CPS41D-, CPS42-, CPS42D-,
CPS441-, CPS441D-, CPS471-, CPS471D-, CPS491-, CPS491D-, CPS64-, CPS71-,
CPS71D-, CPS72-, CPS72D-, CPS76D-, CPS91-, CPS91D-, CPS92-, CPS92D-,
CPS96D-, CTS1-, CYK10-, CYP01D-, CYP02D-, OPS171D-
Region: USA
Approval agency: FMSpråk:
Engelska
Version:
30/11/2020
Filstorlek:
523.6 KB
Filnamn:
FM16US0145XSupp15.pdf
-
-
-
Explosionsskydd
Product family: CeraGel, CeraLiquid, ConduMax H, ConduMax W, InduMax P, Memosens, Messkabel, OEM, OrbiPac, OrbiPore, OrbiSint, OxyMa x H, OxyMax W, TopHit
Product root: CLS15D-, CLS16D-, CLS21D-, CLS50D-, CLS82D-, COS21D-, COS22D-, COS51D-, COS81D-, CPF81D-, CPF82D-, CPS11D-, CPS12D-, C
PS16D-, CPS171D-, CPS41D-, CPS42D-, CPS441D-, CPS471D-, CPS491D-, CPS71D-, CPS72D-, CPS76D-, CPS91D-, CPS92D-, CPS96D-, CYK10-, CYK2
0-, OCLS82D-, OCOS81D-, OPS91D-
Region: Canada
Approval agency: CSA
Protection: IS Cl. I Div. 1Språk:
Engelska
Version:
30/08/2023
Filstorlek:
263.6 KB
Filnamn:
S2_CoFC_80169522_EN.pdf
-
-
-
Anbudstext
Orbipac CPF82 D
Digitale Redox-Messelektrode mit kontaktloser, digitaler
Signalübertragung,
Memosenstechnologie (Speicherung Sensorkenndaten im Elektrodenkopf),
ausgeführt
als Kombi-Elektrode mit integriertem Temperaturfühler und
Teflondiaphragma,
eingebaut in PP-AdapterSpråk:
Tyska
Version:
30/11/2021
Filstorlek:
14.7 KB
Filnamn:
TTCPF82DDE.docx
-