Ultrasonic measurement
Time-of-Flight
Prosonic FMU95

Prosonic FMU95 top hat rail housing ©Endress+Hauser
Prosonic FMU95 field housing ©Endress+Hauser

Time-of-Flight measuring principle

Prosonic FMU95 ©Endress+Hauser

Transmitter in housing for field or top hat rail mounting for up to 10 sensors FDU90/91/92/93/95

Prosonic FMU95 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk solids.

  • Fördelar

    • Simple, menu-guided operation with 6-line plain text display, 15 languages selectable

    • Envelope curves on the display for quick and simple diagnosis

    • Easy operation, diagnosis and measuring point documentation with the supplied "FieldCare" operating program

    • ...

  • Applikationsområde

    Continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk materials with up to 5 or 10 ultrasonic sensors.

    • Measuring range up to 45m (148ft) (depending on sensor and material measured)

    • Calculation of average values...

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Ultrasonic

  • Characteristic / Application

    Separated version with Field housing or top hat rail housing for control cabinet instrumentation, 5 or 10 channel version

  • Specialities

    Protection Class IP 66 / NEMA 4x
    automatic sensor recognition of FDU9x sensors

  • Supply / Communication

    90 ... 253 VAC
    10.5 ... 32 VDC
    Profibus DP

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C ... 60 °C
    (-40 °F ... 140 °F)

  • Communication

    Profibus DP

  • Certificates / Approvals

    ATEX, CSA

  • Options

    Illuminated display, 6 line graphic display with country specific menu guidance

  • Components

    Sensors FDU9x

  • Mätprincip

    Ultrasonic

  • Characteristic / Application

    Separated version with Field housing or top hat rail housing for control cabinet instrumentation, 5 or 10 channel version

  • Specialities

    Protection Class IP 66 / NEMA 4x
    automatic sensor recognition of FDU9x sensors

  • Supply / Communication

    90 ... 253 VAC
    10.5 ... 32 VDC
    Profibus DP

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C ... 60 °C
    (-40 °F ... 140 °F)

  • Communication

    Profibus DP

  • Certificates / Approvals

    ATEX, CSA

  • Options

    Illuminated display, 6 line graphic display with country specific menu guidance, on-site diagnosis with envelope curve on display

  • Components

    Sensors FDU9x

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification
  • 10
    • Nr 10 Order code 52025713

      Housing DIN Rail FMU9x

      Basic version. Consists of: Frame. 2x side part. Locking DIN Rail. Usage: FMU90/FMU95. -For E+H service only-

  • 12
    • Nr 12 Order code 52025702

      Separating web + fixing PC board

      Torx screw, field housing. Usage: FMU90/FMU95.

  • 13
    • Nr 13 Order code 52025712

      Blind cover PC board, 7 pieces

      Material: plastics. Usage: FMU90/FMU95.

  • 20
    • Nr 20 Order code 71037237

      Cover P3 field housing, hinge, FMU95

      Material: plastics. Blind cover, hinge. Usage: FMU95.

    • Nr 20 Order code 71037238

      Cover P3+display field housing, PC,FMU95

      Material: plastics. Display cover, hinge. Usage: FMU95.

    • Nr 20 Order code 71037239

      Front plate wide FMU95 + display

      Display module. Material: plastics. DIN Rail mounting. Usage: FMU95.

    • Nr 20 Order code 71037240

      Front plate wide FMU95

      Material: plastics. DIN Rail mounting. Usage: FMU95.

  • 21
    • Nr 21 Order code 71024576

      Hinge + screws, field housing FMU9x

      Consists of: 2x hinge. 4x screw. Usage: FMU90/FMU95.

    • Order code 71024578

      Screw set FMU9x, leaded, 2 pieces

      Usage: FMU90/FMU95.

  • 25
    • Nr 25 Order code 52025721

      Cable display FMU9x, L=300mm

      Connection cable. Display / basic electronics. Field housing. Usage: FMU90/FMU95.

    • Nr 25 Order code 52025722

      Cable display FMU9x, L=220mm

      Connection cable. Display / basic electronics. DIN Rail mounting. Usage: FMU90/FMU95.

  • 31
    • Nr 31 Order code 71035385

      PC board 1-5 channel, FMU95

      Connection FDU sensors 1...5. Usage: FMU95.

    • Nr 31 Order code 71035387

      PC board 6-10 channel, FMU95

      Connection FDU sensors 6...10. Usage: FMU95.

  • 34
    • Nr 34 Order code 52025720

      PC board PROFIBUS DP FMU90/FMU95

      Usage: FMU90/FMU95.

  • 39
    • Nr 39 Order code 71024577

      PCB connector set FMU9X, 6 pieces

      Consists of: 1x PCB connector power supply. 2x PCB connector relay. 2x PCB connector current. Output/synchronisation. 1x PCB connector sensor output. Usage: FMU90/FMU95.

  • 36
    • Nr 36 Order code 71354876

      PC board power supply AC

      Usage: FMU90/FMU95, NXA20, NXA820/NXA821/NXA822.

    • Order code 71038663

      Remote display FMU95, illuminated

      Panel mounting. Connection cable 3m. Usage: FMU95.

  • 30
    • Nr 30 Order code FMU95X-

      Electronics basic version FMU95X

      Usage: FMU90/FMU95.

    • Order code 71024579

      Fuse set FMU9x, AC+DC

      Consists of: 1x fuse 400mA T, AC version. 1x fuse 2,0A T, DC version. 2x fuse holder. Usage: FMU90/FMU95.

    • Order code 71020897

      Cable 3m, remote display FMU9x

      Connection cable FMU9x / remote display. Usage: FMU90/FMU95.

    • Order code 71007843

      ToF Adapter FXA291

      Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.

    • Order code 52026736

      Adapter cable FMU9x

      Connection service tool RS232(52013675) Usage: FMU90/FMU95.

    • Order code 52024477

      Weather prot.cover FMU90/95 fieldhousing

      Material: 316Ti. Usage: FMU90/FMU95.

    • Order code 52024478

      Mounting plate FMU90/95 fieldhousing

      Material: 316Ti. Usage: pipe, 1" / 2", FMU90/FMU95.

    • Order code 71093130

      Mounting bracket Prosonic S, Micropilot

      Material: 316L. Usage: FDU90/FDU91/FDU91F/FDU92/FDU93/FDU95, FMR10, FMR20, FMU90/FMU95.