Level transmitter, continuous.
Measuring: ultrasonic, contactless.
Sensor enclosure: PVDF.
Max meas. range under ideal condition:
Liquid: 16ft/4m. Solid: 7ft/2m.
Blocking distance: 25cm.
Operating temp. -4..176oF / -20..+80oC
up to -40oC/-40oF with reduced range.
Max operating pressure 3bar abs.
Process connection: NPT1-1/2.
Integrated sound velocity compensation.
Self cleaning effect of sensor membrane.
:: Measuring range freely adjustable.
:: Simple calibration.
-
Successor
-
Cost effective all-round instrument for level applications in liquids and bulk solids
-
Simple products
-
Easy to select, install and operate
Technical excellence
Simplicity
-
Standard products
-
Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
High-end products
-
Highly functional and convenient
Technical excellence
Simplicity
-
Specialized products
-
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections |
Technical excellence |
Simplicity |
Fundamental selection
Meet your basic measurement needs
|
Technical excellence
|
Simplicity
|
Lean selection
Handle your core processes easily
|
Technical excellence
|
Simplicity
|
Extended selection
Optimize your processes with innovative technologies
|
Technical excellence
|
Simplicity
|
Xpert selection
Master your most challenging applications
|
Technical excellence
|
Simplicity
|
-
Characteristic / Application
Main application, Open basins, Storage tanks
-
-
Accuracy
0,25 % of measuring range
-
Ambient temperature
-20 °C ... 60 °C
(-4 °F ... 140 °F)
-
Process temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F)
-
Process pressure / max. overpressure limit
0.7 bar ... 3 bar abs
(10 psi ... 44 psi)
-
-
-
-
-
Max. measurement distance
-
-
-
-
Characteristic / Application
-
-
Accuracy
0,25 % of measuring range
-
Ambient temperature
-20 °C ... 60 °C
(-4 °F ... 140 °F)
-
Process temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F)
-
Process pressure / max. overpressure limit
0.7 bar ... 3 bar abs
(10 psi ... 44 psi)
-
-
-
-
Max. measurement distance
-
-
-
Application limits
Take notice of range diagram
Most downloaded
-
Prosonic T FMU130/131/230/231/232
PROFIBUS P
Operating Instructions
English version - 07/2003
|
Compact transmitters for non-contact level measurements of fluids and
coarse bulk materials
Language:
|
English
|
Version:
|
29/07/2003
|
File size:
|
3 MB
|
File name:
|
ba166fen.pdf
|
9 documents
-
Prosonic T FMU230/231
Technical Information
Compact transmitters for non-contact level measurement of fluids and
coarse bulk materials
|
EN
|
|
Select other language
|
16/01/2014
|
|
|
|
10/02/2005
|
|
|
|
05/08/2003
|
|
|
|
Language:
|
English
|
Version:
|
16/01/2014
|
File size:
|
704.6 KB
|
File name:
|
TI366FEN_0608.pdf
|
-
Ultrasonic Level Measurement
prosonic T FMU 130, 131
prosonic T FMU 230, 231, 232
Compact transmitter for continuous,
non-contact level measurement
Available as a Smart transmitter or
for connection to process control systems
|
EN
|
|
Select other language
|
24/07/2003
|
|
|
|
01/08/1996
|
|
|
|
Language:
|
English
|
Version:
|
24/07/2003
|
File size:
|
657.7 KB
|
File name:
|
ti246fen.pdf
|
-
Prosonic T FMU130/131/230/231/232
PROFIBUS P
Operating Instructions
Compact transmitters for non-contact level measurements of fluids and
coarse bulk materials
|
EN
|
|
Select other language
|
29/07/2003
|
|
|
|
Language:
|
English
|
Version:
|
29/07/2003
|
File size:
|
3 MB
|
File name:
|
ba166fen.pdf
|
-
Prosonic T FMU130/131/230/231/232
4-20mA
Operating Instructions
Compact transmitters for non-contact level measurement of fluids and
coarse bulk materials
|
EN
|
|
Select other language
|
11/06/2008
|
|
|
|
28/07/2003
|
|
|
|
Language:
|
English
|
Version:
|
11/06/2008
|
File size:
|
1.5 MB
|
File name:
|
KA042FA3_0608.pdf
|
-
Prosonic T FMU230, FMU231
Compact transmitters for non-contact level measurement of fluids and
coarse bulk materials
|
EN
|
|
Select other language
|
22/11/2007
|
|
|
|
Language:
|
English
|
Version:
|
22/11/2007
|
File size:
|
1.1 MB
|
File name:
|
Ka058FA2.pdf
|
-
General Station Description (GSD) - to be defined - PROFIBUS PA
Any, PROFIBUS System, Any
File size:
|
48.9 KB
|
File name:
|
EH_PA_LE_Prosonic_0x1502_V01_00_PALIB.zip
|
Device Type:
|
0x1502
|
Firmware:
|
1.3
|
Version:
|
1.00.00
|
Date:
|
14/04/2014
|
-
Electronic Data Description (EDD) - Prosonic T - PROFIBUS PA
SIEMENS, PDM, 6.0 SP5
File size:
|
29.2 KB
|
File name:
|
EH_PA_LE_ProsonicT_0x1502_0x02_0x01_PDM.zip
|
Device Type:
|
0x1502
|
DD Revision:
|
1
|
Firmware:
|
1.3
|
Version:
|
1.00.00
|
Date:
|
07/01/2019
|
-
Device Type Manager (DTM) - Prosonic T - PROFIBUS PA
Endress+Hauser, DeviceCare, 1.07.06
Endress+Hauser, Field Xpert - SMT70, 1.07.00
Endress+Hauser, FieldCare, 2.17.00
File size:
|
227.6 MB
|
File name:
|
EH_Prosonic_T_FMU_x3x_V1_3.zip
|
Device Type:
|
0x1502
|
Firmware:
|
1.3
|
Version:
|
1.5.153.348
|
Date:
|
12/05/2023
|
-
Device Type Manager (DTM) - Prosonic x3x - HART
Endress+Hauser, DeviceCare, 1.07.06
Endress+Hauser, Field Xpert - SMT70, 1.07.00
Endress+Hauser, FieldCare, 2.17.00
File size:
|
228 MB
|
File name:
|
EH_Prosonic_T_FMU_x3x_V2_1___2_2.zip
|
Device Type:
|
0x000A
|
Device Revision:
|
2
|
Firmware:
|
2.2, 2.1
|
Version:
|
1.4.188.39
|
Date:
|
11/05/2023
|
Search spare parts by number in drawing
28 spare parts & accessories
28 spare parts
28 accessories
-
-
-
Cover F9 PPE, HART, orifice plate
-
Cover F9 PPE, orifice plate
-
Cover plug, PAL-boring, bl, PBT-FR
-
Blind plug DIN46320 N Pg16 PA
-
Gasket 64/53, 7x72x3 VMQ, 5 pieces
-
Adapter Pg16 > NPT1/2, CuZn/Ni
-
Coverplate Prosonic T, 2-wire
-
Coverplate Prosonic T, 4-wire
-
Coverplate Prosonic T, PROFIBUS PA
-
Electronics FMU23x 4-20mA 2-wire
-
Electronics FMU23x 4-20mA 2-wire HART
-
Electronics FMU23x 230VAC 4-wire
-
Electronics FMU23x 115VAC 4-wire
-
Electronics FMU23x 24VDC 4-wire
-
Electronics FMU23x 230VAC 4-wire HART
-
Electronics FMU23x 115VAC 4-wire HART
-
Electronics FMU23x 24VDC 4-wire HART
-
Electronics FMU23x PA 1.3-2.0
-
-
Fuse DIN41662-T 0,16 250V 5x20
-
-
Plug-in LCD-display >32x21< pluggable
-
Control unit FMU230/FMU231, 2-wire
-
Control unit FMU23x, 4-wire
-
Control unit FMU23x, PROFIBUS PA
-
Sensor FMU230/FTU230 NPT1-1/2
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .