RMS621
Energy manager

RMS621
Energy manager ©Endress+Hauser

Steam and heat computer for industrial energy calculation of steam and water

The steam and heat computer RMS621 calculates steam mass, steam heat quantity, net steam quantity, steam-heat differential, water heat quantity and water-heat differential in up to 3 simultaneous applications. Bi-directional and splitting range measurements are possible. It supports analog, PFM or pulse signals for flow and pressure sensors. Temperature sensors can be connected in 3- or 4-wire connection or via transmitter. A loop power supply is available for each analog or pulse input.

  • Fördelar

    • Calculation of the following applications:
      Steam mass, steam heat quantity, net steam quantity, steam-heat differential, water heat quantity, water heat differential

    • Simultaneous calculation of up to three applications per device

    • Bi-directional flow...

  • Applikationsområde

    • Energy management

    • Chemical industry

    • Heating and air conditioning

    • Pharmaceutical industry

    • Food and beverage

    • Plant and panel manufacture

Details

  • Mätprincip

    Energy manager

  • Function

    Steam and water balancing for industrial energy management

  • Certification

    -

  • Input

    2...6x RTD

    2...8x I

    2...8x PFM

    2...8x Impulse (aktive)

    2...8x Impulse (passive)

  • Output

    3...9x transmitter power supply

  • Relay output

    1...7 no contacts

  • Auxiliary power supply

    90...250V AC 50/60 Hz

    20...28V AC 50/60 Hz

    20...36V DC

  • Dimensions (wxhxd)

    135 x 108 x 114 mm

    (5.32" x 4.25" x 4.49")

  • Software

    International calculation standards for steam and water

  • Operation

    Soft keys RS232 and operation software ReadWin 2000

  • Display

    LC-Dot-Matrix 160 x 80 dots

  • Others

    additional interface (e.g. ModBus, PROFIBUS, RS232

  • Calculations

    IAPWS IF97

    ISO 5167

  • Mätprincip

    Energy manager

  • Measuring principle

    Energymanager

  • Function

    Steam and water balancing for industrial energy management

  • Calculations

    heat quantity

    heat quantity difference

  • Number of applications

    3

  • Data storage

    no

  • Calculation standards

    IAPWS-97

  • Communication

    1 x RS232

    2 x RS485

    PROFIBUS DP

    M-Bus

    Modbus RTU

  • Power supply

    Not defined

  • Loop power supply

    90...250V AC 50/60 Hz

    20...28V AC 50/60 Hz

    20...36V DC

  • Protection class

    IP20

  • Input

    2...6x RTD

    2...8x I

    2...8x PFM

    2...8x Impulse (aktive)

    2...8x Impulse (passive)

  • Output

    3...9x transmitter power supply

  • Dimensions (WxHxD)

    135 x 108 x 114 mm (5.32" x 4.25" x 4.49")

  • Operation

    Soft keys RS232 and operation software ReadWin 2000

  • Display

    Dot-Matrix LCD, backlit, colour change in case of alarm event

  • Software functions

    International calculation standards for steam and water

  • Certificates

    EAC

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification
  • 1
  • 2
    • Nr 2 Order code RMS621X-HC

      Housing cpl. without front, incl. 3x dummy inserts

  • 3
  • 4
  • 5
    • Nr 5 Order code RMS621X-DA

      Display for units with software FSU00xA

    • Nr 5 Order code RMS621X-DB

      Front board, vers. w/o display, FSU00xA for units with software FSU00xA

    • Nr 5 Order code RMS621X-DC

      Display + front cover, software FSU00xA for units with software FSU00xA

    • Nr 5 Order code RMS621X-DE

      Display for units with software FCS00xA

    • Nr 5 Order code RMS621X-DF

      Front board,vers.without display FCS00xA for units with software FCS00xA

    • Nr 5 Order code RMS621X-DG

      Display + front cover, software FCS00xA for units with software FCS00xA

  • 6
    • Nr 6 Order code RMS621A-TA

      Extension board temperature (Pt100/Pt500/Pt1000)cpl.incl. connector + fixing frame

  • 7
    • Nr 7 Order code RMS621A-UA

      Extension board universal (PFM/pulse/analogue/loop power) cpl. incl.connector + fixing frame

  • 8
  • 9
    • Nr 9 Order code 51004062

      Terminal plug-in 4pol.SMSTB2,5 91/92/53/

      Relay terminal/loop power

  • 10
    • Nr 10 Order code 51004063

      Terminal plug-in 4pol.SMSTB2,5 82/81/10/

      Analog terminal 1 (PFM/pulse/analog/loop power)

  • 11
    • Nr 11 Order code 51004064

      Terminal plug-in 4pol.SMSTB2,5 83/81/110

      Analog terminal 2 (PFM/pulse/analog/loop power)

  • 14
    • Nr 14 Order code 51004065

      Terminal plug-in 4pol.SMSTB2,5 104..101

      Terminal RS485

  • 15/17
    • Nr 15/17 Order code 51004066

      Terminal plug-in 4pol.SMSTB2,5 134..131

      Output terminal (analog/pulse)

  • 12
    • Nr 12 Order code 51004067

      Terminal plug-in 4pol.SMSTB2,5 1/5/6/2

      Terminal temperat.1(Pt100/Pt500/Pt1000)

  • 13
    • Nr 13 Order code 51004068

      Terminal plug-in 4pol.SMSTB2,5 3/7/8/4

      Terminal temperat.2(Pt100/Pt500/Pt1000)

  • 19
    • Nr 19 Order code 51004907

      Terminal RMx621/FML621, Input 1, RTD

      Pt100/Pt500/Pt1000, gray

  • 20
    • Nr 20 Order code 51004908

      Terminal RMx/FML621, Input 2, RTD

      Pt100/Pt500/Pt1000, gray

  • 22
    • Nr 22 Order code 51004909

      Terminal RMx/FML621, Input 2, 4-20mA

      PFM, pulse, loop power, gray

  • 21
    • Nr 21 Order code 51004910

      Terminal RMx/FML621, Input 1, 4-20mA

      PFM, pulse, loop power, gray

  • 18
  • 16
    • Order code RMS621A-AA

      Display-/operat. keys: in offset FCS00xA housing for panel mounting 144x72mm. For units with software FCS00xA. By using display on unit and display in offset simultaneous only usable together with the "new" unit display (FW: >=3.02.03)

    • Order code RMS621A-AB

      Display-/operat. keys: in offset FSU00xA housing for panel mounting 144x72mm. For units with software FSU00xA. By using display on unit + display in offset simultaneous only usable together with "old" unit display (FW: < 3.02.03)

    • Order code RMS621A-P1

      Profibus-DP slave module from software >=V2.01.00 for DIN rail

    • Order code 71402350

      Set, 10x fixing lever housing

      for RMA42x/RMx621/RTA421/RN221N/TMT12x

    • Order code 52010132

      Housing Field, R4 182x180x165, 5xM20, PC

      Protection housing Minitec. Synthetic housing with transparent cover. Protection IP66. 4x22.5mm / 2x45mm. Usage: FTL825.

    • Order code RMS621C-

      CPU Board RMS621C

    • Order code RXU10-

      Accessories Datamanager RXU10