Proline Promass 83S
Coriolis flowmeter

Coriolis flowmeter - Proline Promass 83S ©Endress+Hauser

The Coriolis Flow Measuring Principle

Easy-to-clean flowmeter with self-drainable single-tube system & extended transmitter functionality

Promass S is at the forefront in hygienic design – Endress+Hauser’s industry-optimized measurement solution meets all the hygienic requirements for installation in the Food and Beverage industry. Combined with the Promass 83 transmitter with touch control, four line display and extended functionality like software options for filling and dosing, concentration measurement or advanced diagnostics, Promass 83S offers superior performance in applications requiring optimal cleanability.

  • Fördelar

    • Increased process safety – easy cleanable and fully self-drainable tube design

    • Fewer process measuring points – multivariable measurement (flow, density, temperature)

    • Space-saving installation – no in/outlet run needs

    • Quality – software for filling &...

  • Applikationsområde

    • Measuring principle operates independently of physical fluid properties such as viscosity or density

    • Dedicated for applications requiring optimal cleanability under hygienic conditions.

    Device properties

    • Large range of hygienic process connections

    • 3-A...

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Coriolis

  • Product headline

    The easy‐to‐clean flowmeter with self‐drainable single‐tube system and extended transmitter functionality. Dedicated for applications requiring optimal cleanability under hygienic conditions.

  • Sensor features

    Reduced installation costs – fully self‐drainable tube design enables compact horizontal mounting. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Large range of hygienic process connections. 3-A and EHEDG conform.

  • Transmitter features

    Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.

  • Nominal diameter range

    DN 8 to 50 (⅜ to 2")

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4435 (316L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 70 000 kg/h (0 to 2570 lb/min)

  • Max. process pressure

    PN 63, Class 300, 40K

  • Medium temperature range

    –50 to +150 °C (–58 to +302 °F)

  • Ambient temperature range

    Standard: –20 to +60 °C (–4 to +140 °F)
    Option: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium
    1.4301 (304), sheet
    CF3M (316L), cast

  • Degree of protection

    IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency/switch output (passive)
    Relay

  • Inputs

    2 modular inputs:
    Status
    0‐20 mA (active)/4‐20 mA (active/passive)

  • Digital communication

    HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    ATEX, IECEx, FM, CSA, NEPSI, TIIS

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    3-A, FDA

  • Mätprincip

    Coriolis

  • Characteristic / Application

    Coriolis mass flow and density measurement for the food and beverage industry.

  • Ambient temperature

    -20...+65°C
    (-4...+140°F)

  • Process temperature

    -50...+150°C
    (-58...+302°F)

  • Process pressure absolute

    PN 16...40
    Cl 150...300
    JIS 20...40K

  • Wetted parts

    904L/1.4539

  • Output

    4...20mA
    Pulse/Frequency (10KHz, active/passive)
    Relays/Status

  • Certificates / Approvals

    ATEX
    FM
    CSA
    IECEx
    TIIS
    NEPSI

  • Mätprincip

    Coriolis

  • Product headline

    The easy‐to‐clean flowmeter with self‐drainable single‐tube system and extended transmitter functionality. Dedicated for applications requiring optimal cleanability under hygienic conditions.

  • Sensor features

    Reduced installation costs – fully self‐drainable tube design enables compact horizontal mounting. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Large range of hygienic process connections. 3-A and EHEDG conform.

  • Transmitter features

    Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.

  • Nominal diameter range

    DN 8 to 50 (⅜ to 2")

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4435 (316L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 70 000 kg/h (0 to 2570 lb/min)

  • Max. process pressure

    PN 63, Class 300, 40K

  • Medium temperature range

    –50 to +150 °C (–58 to +302 °F)

  • Ambient temperature range

    Standard: –20 to +60 °C (–4 to +140 °F)
    Option: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium
    1.4301 (304), sheet
    CF3M (316L), cast

  • Degree of protection

    IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency/switch output (passive)
    Relay

  • Inputs

    2 modular inputs:
    Status
    0‐20 mA (active)/4‐20 mA (active/passive)

  • Digital communication

    HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    ATEX, IECEx, FM, CSA, NEPSI, TIIS

  • Other approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
    PED, CRN
    3-A, FDA

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    3-A, FDA

  • Mätprincip

    Coriolis

  • Product headline

    The easy‐to‐clean flowmeter with self‐drainable single‐tube system and extended transmitter functionality. Dedicated for applications requiring optimal cleanability under hygienic conditions.

  • Sensor features

    Reduced installation costs – fully self‐drainable tube design enables compact horizontal mounting. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Large range of hygienic process connections. 3-A and EHEDG conform.

  • Transmitter features

    Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.

  • Nominal diameter range

    DN 8 to 50 (⅜ to 2")

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4435 (316L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 70 000 kg/h (0 to 2570 lb/min)

  • Max. process pressure

    PN 63, Class 300, 40K

  • Medium temperature range

    –50 to +150 °C (–58 to +302 °F)

  • Ambient temperature range

    Standard: –20 to +60 °C (–4 to +140 °F)
    Option: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium
    1.4301 (304), sheet
    CF3M (316L), cast

  • Degree of protection

    IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency/switch output (passive)
    Relay

  • Inputs

    2 modular inputs:
    Status
    0‐20 mA (active)/4‐20 mA (active/passive)

  • Digital communication

    HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    ATEX, IECEx, FM, CSA, NEPSI, TIIS

  • Other approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
    PED, CRN
    3-A, FDA

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    3-A, FDA

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification
  • F
    • Nr F Order code 50098557

      Kit power s.b. 40/8X/65 220V REx000

      220V = 85-260VAC

    • Nr F Order code 71039431

      Kit p.s.b.40/8X 220V REx000 HE

      HE = harsh environment 220V = 85-260VAC

    • Nr F Order code 71039431

      Kit p.s.b.40/8X 220V REx000 HE

      HE = harsh environment 220V = 85-260VAC

    • Nr F Order code 50098558

      Kit power s.b. 40/8X/65 220V REx120 Ex

      220V = 85-260VAC

    • Nr F Order code 71039432

      Kit p.s.b.8X 220V REx120 HE Ex

      HE = harsh environment 220V = 85-260VAC

    • Nr F Order code 71097758

      Kit p.s.b. 40/8X 220V REx330 Ex

      220V = 85-260VAC

    • Nr F Order code 71097760

      Kit p.s.b.8X 220V REx330 HE Ex

      220V = 85-260VAC HE = harsh environment

    • Nr F Order code 50098565

      Kit P.s.b. 40/8X/65 24V REx000

      24V = 20-55VAC / 16-62VDC

    • Nr F Order code 71039434

      Kit p.s.b.8X 24V REx000 HE

      HE = harsh environment 24V = 20-55VAC / 16-62VDC

    • Nr F Order code 50098566

      Kit P.s.b. 40/8X/65 24V REx120 Ex

      24V = 20-55VAC / 16-62VDC

    • Nr F Order code 71039436

      Kit P.s.b. 8X 24V REx120 HE Ex

      HE = harsh environment 24V = 20-55VAC / 16-62VDC

    • Nr F Order code 71097759

      Kit P.s.b. 40/8X 24V REx330 Ex

      24V = 20-55VAC/16-62VDC

    • Nr F Order code 71097761

      Kit P.s.b. 8X 24V REx330 HE Ex

      24V = 20-55VAC/16-62VDC HE = harsh environment

  • 7
  • B
    • Nr B Order code 50106097

      Kit meas.amplifier Promass 83/8ME WEA EX

      Language: FR, ES, IT, NL, PT, DE, EN

    • Nr B Order code 71039409

      Kit meas. amplifier 83 WEA HE EX

      Language: FR, ES, IT, NL, PT, DE, EN HE = harsh environment

    • Nr B Order code 50106098

      Kit meas. amplifier PMASS 83 EES EX

      Language: SV, FI, NO, RU, PL, CS, EN

    • Nr B Order code 71039410

      Kit meas. amplifier 83 EES HE EX

      Language: SV, FI, NO, RU, PL, CS, EN HE = harsh environment

    • Nr B Order code 50106099

      Kit meas. amplifier PMASS 83 SEA EX

      Language: JA, ID, EN

    • Nr B Order code 71039411

      Kit meas. amplifier 83 SEA HE EX

      Language: JA, ID, EN HE = harsh environment

    • Nr B Order code 50108135

      Kit meas. amplifier Pmass 83 CN EX

      Language: ZH + EN

    • Nr B Order code 71039412

      Kit meas. amplifier 83 CN HE EX

      Language: ZH, EN HE = harsh environment

    • Nr B Order code 71261695

      Kit amp. 83, HART7, DE+FR+IT+ES+EN, EX

      Language: DE+FR+IT+ES+EN

    • Nr B Order code 71261696

      Kit amp. 83,HART7, DE+FR+IT+ES+EN, HE,EX

      Language: DE+FR+IT+ES+EN HE = harsh environment

    • Nr B Order code 71261697

      Kit amp. 83, HART7, RU+NL+PT+CS+EN, EX

      Language: RU+NL+PT+CS+EN

    • Nr B Order code 71261698

      Kit amp. 83,HART7, RU+NL+PT+CS+EN, HE,EX

      Language: RU+NL+PT+CS+EN HE = harsh environment

    • Nr B Order code 71261699

      Kit amp. 83, HART7, ZH+PL+ID+EN, EX

      Language: ZH+PL+ID+EN

    • Nr B Order code 71261700

      Kit amp. 83, HART7, ZH+PL+ID+EN, HE, EX

      Language: ZH+PL+ID+EN HE = harsh environment

    • Nr B Order code 71261701

      Kit amp. 83, HART7, JA+SV+NO+FI+EN

      Language: JA+SV+NO+FI+EN

    • Nr B Order code 71261702

      Kit amp. 83,HART7, JA+SV+NO+FI+EN, HE

      Language: JA+SV+NO+FI+EN HE = harsh environment

  • C
    • Nr C Order code 50098300

      Kit commodul current/freq./2Relay Ex

      53/55/83/93/65

    • Nr C Order code 71039475

      Kit I/O current/frequency/2Relay HE EX

      53/55/83 HE = harsh environment

    • Nr C Order code 50098301

      Kit com 53/55/83/93 curr./freq. out Ex

    • Nr C Order code 71039476

      Kit I/O current/frequency out HE EX

      53/55/83 HE = harsh environment

    • Nr C Order code 50098302

      Kit commodul Iout passive/Frequency Exi

      50/53/40/8X/93/65

    • Nr C Order code 71039479

      Kit I/O Iout passive/Frequency HE Exi

      50/53/8X HE = harsh environment

    • Nr C Order code 50098303

      Kit commodul Iout active/Frequency Exi

      50/53/40/8X/93/65

    • Nr C Order code 71039478

      Kit I/O Iout active/Frequency HE Exi

      50/53/8X HE = harsh environment

    • Nr C Order code 71066579

      Kit I/O Profibus PA Ex

      50/53/55/80/83/93/65

    • Nr C Order code 71066580

      Kit I/O 50/53/55/80/83 Profib. PA HE Ex

      HE = harsh environment

    • Nr C Order code 50101264

      Kit I/O Foundation Fieldbus C02 Ex

      53/55/83/93

    • Nr C Order code 71095035

      Kit I/O Foundation Fieldbus C14 EX

      53/55/83/93/65

    • Nr C Order code 50101264

      Kit I/O Foundation Fieldbus C02 Ex

      53/55/83/93

    • Nr C Order code 71095035

      Kit I/O Foundation Fieldbus C14 EX

      53/55/83/93/65

    • Nr C Order code 71039483

      Kit I/O Foundation Fieldbus HE C02 EX

      53/55/83 HE = Harsh Environment

    • Nr C Order code 71095037

      Kit I/O Foundation Fieldbus HE C14 EX

      53/55/83 HE = Harsh Environment

    • Nr C Order code 50104625

      Kit com 83/65 2x Iout aktiv Exi

    • Nr C Order code 71039480

      Kit I/O 83 2x Iout active HE Exi

      HE = harsh environment

    • Nr C Order code 50104626

      Kit com 83/65 2x Iout passiv Exi

    • Nr C Order code 71039481

      Kit I/O 83 2x Iout passive HE Exi

      HE = harsh environment

    • Nr C Order code 71021742

      Kit I/O 50/53/55/83/65/8ME Profib. DP Ex

    • Nr C Order code 71039484

      Kit I/O 50/53/55/83 Profibus DP HE EX

      HE = harsh environment

  • D
    • Nr D Order code 71021743

      Kit Com ModbusRS485+stat.In 2Interf.Ex

      53/83/84/65/8CN/8DF

    • Nr D Order code 71039477

      Kit I/O current out 3 Interface HE EX

      53/55/8X HE = harsh environment

    • Nr D Order code 50108002

      Kit I/O Profib. DP+Stat.In 2 Interf. Ex

      53/55/83/93

    • Nr D Order code 71039485

      Kit I/O Modb.RS485+Stat.In 2Interf.HE EX

      53/83/84/8CN/8DF HE = Harsh environment

    • Nr D Order code 50096833

      Kit Commodul current out 3 Interface Ex

      53/55/8X/93/65

    • Nr D Order code 71039486

      Kit I/O Profib.DP+Stat.In 2 Interf.HE EX

      53/55/83 HE = harsh environment

    • Nr D Order code 71105712

      Kit I/O Modul 53/83 Ethernet

      Including Subprint Ethernet

  • 2
    • Nr 2 Order code 50096834

      Kit Sub PCB current out

      53/55/8X/93/65

    • Nr 2 Order code 50096834

      Kit Sub PCB current out

      53/55/8X/93/65

    • Nr 2 Order code 71039487

      Kit Sub PCB current out HE

      53/55/8X HE = harsh environment

    • Nr 2 Order code 71039487

      Kit Sub PCB current out HE

      53/55/8X HE = harsh environment

  • 3
    • Nr 3 Order code 50096835

      Kit Sub PCB frequency out

      53/55/80/83/93/65

    • Nr 3 Order code 50096835

      Kit Sub PCB frequency out

      53/55/80/83/93/65

    • Nr 3 Order code 71039489

      Kit Sub PCB frequency out HE

      53/55/80/83 HE = harsh environment

    • Nr 3 Order code 71039489

      Kit Sub PCB frequency out HE

      53/55/80/83 HE = harsh environment

  • 4
    • Nr 4 Order code 50096837

      Kit Sub PCB Status input

      53/55/8X/93/65

    • Nr 4 Order code 71039492

      Kit Sub PCB Status input HE

      53/55/8X HE = harsh environment

  • 5
    • Nr 5 Order code 50096836

      Kit Sub PCB Relay out

      53/55/83/84/93/8CN/8DF

    • Nr 5 Order code 50096836

      Kit Sub PCB Relay out

      53/55/83/84/93/8CN/8DF

    • Nr 5 Order code 71039491

      Kit Sub PCB Relay out HE

      53/55/83/84/8CN/8DF HE = Harsh environment

    • Nr 5 Order code 71039491

      Kit Sub PCB Relay out HE

      53/55/83/84/8CN/8DF HE = Harsh environment

  • 6
  • 37
  • E
  • J
    • Nr J Order code 50096755

      Kit display modul Wall enclosure

      53/55/83/84/93/8CN/8DF

  • G
  • 21
  • H
  • 19
    • Nr 19 Order code 50098637

      Kit connec. board PMASS8X wall enclo

    • Nr 19 Order code 71039493

      Kit connec. board 8X wall enclosur HE

      HE = harsh environment

  • 18
  • A
    • Nr A Order code 50098705

      Kit connection board 8X FS

      Sensor: A/I/M/F/H/E/S/P/O/X

    • Nr A Order code 71039494

      Kit connection board 8X FS HE

      Sensor: A/I/M/F/H/E/S/P/O/X HE = harsh environment

    • Nr A Order code 50098706

      Kit connection board 8X FS Ex

      Sensor: A/I/M/F/H/E/S/P/O/X

    • Nr A Order code 71039495

      Kit connection board 8X FS HE EX

      Sensor: A/I/M/F/H/E/S/O/X, HE = harsh environment

  • 29
  • 30
  • 1
  • S
    • Nr S Order code 71003952

      Kit S-Dat Promass 83/8ME programmed

      Serialnumber is forceful required

  • 17
  • 8
  • 32
  • 9
  • 33
  • 10
    • Nr 10 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

    • Nr 10 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

  • 34
  • 35
  • 15
  • 12
  • 14
  • 36
  • 13
  • 16
  • 20
  • 11
  • 23
    • Nr 23 Order code 50098701

      Kit Part 8X Stainless housing comp.

      Sensor: A/I/M/F/H/S/P

  • 22
    • Nr 22 Order code 50098702

      Kit Part 8X fieldhousing compact

      Sensor: A/I/M/F/H/S/P/O

  • 24
    • Nr 24 Order code 50098704

      Kit housing gaskets FS

      Sensor: A/I/M/F/H/E/S/P/C/O/X

  • 28
    • Order code 83XXX-

      Promass 83, transmitter

    • Order code DK8SO-

      Promass 83, software package

      Chip for release of software functionality. Note: The license is locked to a specific serial number (S-DAT).

    • Order code DK8WM-

      Transmitter 80/83/84, mounting set

  • Ersättare