Enter at least 2 characters to start the search.

Promass 83P

Coriolis flowmeter - Proline Promass 83P ©Endress+Hauser

This product is no longer available.

Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Coriolis

  • Product headline

    The specialist for life sciences with extended transmitter functionality. Dedicated for applications under sterile conditions in the life sciences industry.

  • Sensor features

    Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. ASME BPE, 3-A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L).

  • Transmitter features

    Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.

  • Nominal diameter range

    DN 8 to 50 (⅜ to 2")

  • Wetted materials

    Measuring tube: 1.4435 (316L)
    Connection: 1.4435 (316L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 70 000 kg/h (0 to 2570 lb/min)

  • Max. process pressure

    PN 63, Class 300, 40K

  • Medium temperature range

    –50 to +200 °C (–58 to +392 °F)

  • Ambient temperature range

    Standard: –20 to +60 °C (–4 to +140 °F)
    Option: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium
    1.4301 (304), sheet
    CF3M (316L), cast

  • Degree of protection

    IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency/switch output (passive)
    Relay

  • Inputs

    2 modular inputs:
    Status
    0‐20 mA (active)/4‐20 mA (active/passive)

  • Digital communication

    HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus
    RS485, EtherNet/IP

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    ATEX, IECEx, FM, CSA, NEPSI

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    3-A, FDA, ASME BPE, ISPE

  • Mätprincip

    Coriolis

  • Characteristic / Application

    Coriolis mass flowmeter complying with ASME BPE, ISPE, FDA, 3-A

  • Ambient temperature

    -20...+65°C
    (-4...+140°F)

  • Process temperature

    -50...+200°C
    (-58...+392°F)

  • Process pressure absolute

    PN 16...40
    Cl 150...300
    JIS 20...40K

  • Wetted parts

    316L/1.4435

  • Output

    4...20mA
    Pulse/Frequency (10KHz, active/passive)
    Relays/Status

  • Certificates / Approvals

    ATEX
    FM
    CSA IECEx TIIS NEPSI

  • Mätprincip

    Coriolis

  • Product headline

    The specialist for life sciences with extended transmitter functionality. Dedicated for applications under sterile conditions in the life sciences industry.

  • Sensor features

    Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. ASME BPE, 3-A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L).

  • Transmitter features

    Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.

  • Nominal diameter range

    DN 8 to 50 (⅜ to 2")

  • Wetted materials

    Measuring tube: 1.4435 (316L)
    Connection: 1.4435 (316L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 70 000 kg/h (0 to 2570 lb/min)

  • Max. process pressure

    PN 63, Class 300, 40K

  • Medium temperature range

    –50 to +200 °C (–58 to +392 °F)

  • Ambient temperature range

    Standard: –20 to +60 °C (–4 to +140 °F)
    Option: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium
    1.4301 (304), sheet
    CF3M (316L), cast

  • Degree of protection

    IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency/switch output (passive)
    Relay

  • Inputs

    2 modular inputs:
    Status
    0‐20 mA (active)/4‐20 mA (active/passive)

  • Digital communication

    HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus
    RS485, EtherNet/IP

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    ATEX, IECEx, FM, CSA, NEPSI

  • Other approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
    PED, CRN
    3-A, FDA, ASME BPE, ISPE

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    3-A, FDA, ASME BPE, ISPE

  • Mätprincip

    Coriolis

  • Product headline

    The specialist for life sciences with extended transmitter functionality. Dedicated for applications under sterile conditions in the life sciences industry.

  • Sensor features

    Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. ASME BPE and 3-A conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L).

  • Transmitter features

    Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.

  • Nominal diameter range

    DN 8 to 50 (⅜ to 2")

  • Wetted materials

    Measuring tube: 1.4435 (316L)
    Connection: 1.4435 (316L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 70 000 kg/h (0 to 2570 lb/min)

  • Max. process pressure

    PN 63, Class 300, 40K

  • Medium temperature range

    –50 to +200 °C (–58 to +392 °F)

  • Ambient temperature range

    Standard: –20 to +60 °C (–4 to +140 °F)
    Option: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium
    1.4301 (304), sheet
    CF3M (316L), cast

  • Degree of protection

    IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency/switch output (passive)
    Relay

  • Inputs

    2 modular inputs:
    Status
    0‐20 mA (active)/4‐20 mA (active/passive)

  • Digital communication

    HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus
    RS485, EtherNet/IP

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    ATEX, IECEx, FM, CSA, NEPSI

  • Other approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
    PED, CRN
    3-A, FDA, ASME BPE, ISPE

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    3-A, FDA, ASME BPE, ISPE

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification
  • F
    • Nr F Order code 50098557

      Kit power s.b. 40/8X/65 220V REx000

      220V = 85-260VAC

    • Nr F Order code 71039431

      Kit p.s.b.40/8X 220V REx000 HE

      HE = harsh environment 220V = 85-260VAC

    • Nr F Order code 71039431

      Kit p.s.b.40/8X 220V REx000 HE

      HE = harsh environment 220V = 85-260VAC

    • Nr F Order code 50098558

      Kit power s.b. 40/8X/65 220V REx120 Ex

      220V = 85-260VAC

    • Nr F Order code 71039432

      Kit p.s.b.8X 220V REx120 HE Ex

      HE = harsh environment 220V = 85-260VAC

    • Nr F Order code 71097758

      Kit p.s.b. 40/8X 220V REx330 Ex

      220V = 85-260VAC

    • Nr F Order code 71097760

      Kit p.s.b.8X 220V REx330 HE Ex

      220V = 85-260VAC HE = harsh environment

    • Nr F Order code 50098565

      Kit P.s.b. 40/8X/65 24V REx000

      24V = 20-55VAC / 16-62VDC

    • Nr F Order code 71039434

      Kit p.s.b.8X 24V REx000 HE

      HE = harsh environment 24V = 20-55VAC / 16-62VDC

    • Nr F Order code 50098566

      Kit P.s.b. 40/8X/65 24V REx120 Ex

      24V = 20-55VAC / 16-62VDC

    • Nr F Order code 71039436

      Kit P.s.b. 8X 24V REx120 HE Ex

      HE = harsh environment 24V = 20-55VAC / 16-62VDC

    • Nr F Order code 71097759

      Kit P.s.b. 40/8X 24V REx330 Ex

      24V = 20-55VAC/16-62VDC

    • Nr F Order code 71097761

      Kit P.s.b. 8X 24V REx330 HE Ex

      24V = 20-55VAC/16-62VDC HE = harsh environment

  • 7
  • B
    • Nr B Order code 50106097

      Kit meas.amplifier Promass 83/8ME WEA EX

      Language: FR, ES, IT, NL, PT, DE, EN

    • Nr B Order code 71039409

      Kit meas. amplifier 83 WEA HE EX

      Language: FR, ES, IT, NL, PT, DE, EN HE = harsh environment

    • Nr B Order code 50106098

      Kit meas. amplifier PMASS 83 EES EX

      Language: SV, FI, NO, RU, PL, CS, EN

    • Nr B Order code 71039410

      Kit meas. amplifier 83 EES HE EX

      Language: SV, FI, NO, RU, PL, CS, EN HE = harsh environment

    • Nr B Order code 50106099

      Kit meas. amplifier PMASS 83 SEA EX

      Language: JA, ID, EN

    • Nr B Order code 71039411

      Kit meas. amplifier 83 SEA HE EX

      Language: JA, ID, EN HE = harsh environment

    • Nr B Order code 50108135

      Kit meas. amplifier Pmass 83 CN EX

      Language: ZH + EN

    • Nr B Order code 71039412

      Kit meas. amplifier 83 CN HE EX

      Language: ZH, EN HE = harsh environment

    • Nr B Order code 71261695

      Kit amp. 83, HART7, DE+FR+IT+ES+EN, EX

      Language: DE+FR+IT+ES+EN

    • Nr B Order code 71261696

      Kit amp. 83,HART7, DE+FR+IT+ES+EN, HE,EX

      Language: DE+FR+IT+ES+EN HE = harsh environment

    • Nr B Order code 71261697

      Kit amp. 83, HART7, RU+NL+PT+CS+EN, EX

      Language: RU+NL+PT+CS+EN

    • Nr B Order code 71261698

      Kit amp. 83,HART7, RU+NL+PT+CS+EN, HE,EX

      Language: RU+NL+PT+CS+EN HE = harsh environment

    • Nr B Order code 71261699

      Kit amp. 83, HART7, ZH+PL+ID+EN, EX

      Language: ZH+PL+ID+EN

    • Nr B Order code 71261700

      Kit amp. 83, HART7, ZH+PL+ID+EN, HE, EX

      Language: ZH+PL+ID+EN HE = harsh environment

    • Nr B Order code 71261701

      Kit amp. 83, HART7, JA+SV+NO+FI+EN

      Language: JA+SV+NO+FI+EN

    • Nr B Order code 71261702

      Kit amp. 83,HART7, JA+SV+NO+FI+EN, HE

      Language: JA+SV+NO+FI+EN HE = harsh environment

  • C
    • Nr C Order code 50098300

      Kit commodul current/freq./2Relay Ex

      53/55/83/93/65

    • Nr C Order code 71039475

      Kit I/O current/frequency/2Relay HE EX

      53/55/83 HE = harsh environment

    • Nr C Order code 50098301

      Kit com 53/55/83/93 curr./freq. out Ex

    • Nr C Order code 71039476

      Kit I/O current/frequency out HE EX

      53/55/83 HE = harsh environment

    • Nr C Order code 50098302

      Kit commodul Iout passive/Frequency Exi

      50/53/40/8X/93/65

    • Nr C Order code 71039478

      Kit I/O Iout active/Frequency HE Exi

      50/53/8X HE = harsh environment

    • Nr C Order code 50098303

      Kit commodul Iout active/Frequency Exi

      50/53/40/8X/93/65

    • Nr C Order code 71039479

      Kit I/O Iout passive/Frequency HE Exi

      50/53/8X HE = harsh environment

    • Nr C Order code 71066579

      Kit I/O Profibus PA Ex

      50/53/55/80/83/93/65

    • Nr C Order code 71066580

      Kit I/O 50/53/55/80/83 Profib. PA HE Ex

      HE = harsh environment

    • Nr C Order code 50101264

      Kit I/O Foundation Fieldbus C02 Ex

      53/55/83/93

    • Nr C Order code 71095035

      Kit I/O Foundation Fieldbus C14 EX

      53/55/83/93/65

    • Nr C Order code 50101264

      Kit I/O Foundation Fieldbus C02 Ex

      53/55/83/93

    • Nr C Order code 71095035

      Kit I/O Foundation Fieldbus C14 EX

      53/55/83/93/65

    • Nr C Order code 71039483

      Kit I/O Foundation Fieldbus HE C02 EX

      53/55/83 HE = Harsh Environment

    • Nr C Order code 71095037

      Kit I/O Foundation Fieldbus HE C14 EX

      53/55/83 HE = Harsh Environment

    • Nr C Order code 50104625

      Kit com 83/65 2x Iout aktiv Exi

    • Nr C Order code 71039480

      Kit I/O 83 2x Iout active HE Exi

      HE = harsh environment

    • Nr C Order code 50104626

      Kit com 83/65 2x Iout passiv Exi

    • Nr C Order code 71039481

      Kit I/O 83 2x Iout passive HE Exi

      HE = harsh environment

    • Nr C Order code 71021742

      Kit I/O 50/53/55/83/65/8ME Profib. DP Ex

    • Nr C Order code 71039484

      Kit I/O 50/53/55/83 Profibus DP HE EX

      HE = harsh environment

  • D
    • Nr D Order code 71021743

      Kit Com ModbusRS485+stat.In 2Interf.Ex

      53/83/84/65/8CN/8DF

    • Nr D Order code 71039485

      Kit I/O Modb.RS485+Stat.In 2Interf.HE EX

      53/83/84/8CN/8DF HE = Harsh environment

    • Nr D Order code 50108002

      Kit I/O Profib. DP+Stat.In 2 Interf. Ex

      53/55/83/93

    • Nr D Order code 71039486

      Kit I/O Profib.DP+Stat.In 2 Interf.HE EX

      53/55/83 HE = harsh environment

    • Nr D Order code 50096833

      Kit Commodul current out 3 Interface Ex

      53/55/8X/93/65

    • Nr D Order code 71039477

      Kit I/O current out 3 Interface HE EX

      53/55/8X HE = harsh environment

    • Nr D Order code 71105712

      Kit I/O Modul 53/83 Ethernet

      Including Subprint Ethernet

  • 2
    • Nr 2 Order code 50096834

      Kit Sub PCB current out

      53/55/8X/93/65

    • Nr 2 Order code 50096834

      Kit Sub PCB current out

      53/55/8X/93/65

    • Nr 2 Order code 71039487

      Kit Sub PCB current out HE

      53/55/8X HE = harsh environment

    • Nr 2 Order code 71039487

      Kit Sub PCB current out HE

      53/55/8X HE = harsh environment

  • 3
    • Nr 3 Order code 50096835

      Kit Sub PCB frequency out

      53/55/80/83/93/65

    • Nr 3 Order code 50096835

      Kit Sub PCB frequency out

      53/55/80/83/93/65

    • Nr 3 Order code 71039489

      Kit Sub PCB frequency out HE

      53/55/80/83 HE = harsh environment

    • Nr 3 Order code 71039489

      Kit Sub PCB frequency out HE

      53/55/80/83 HE = harsh environment

  • 4
    • Nr 4 Order code 50096837

      Kit Sub PCB Status input

      53/55/8X/93/65

    • Nr 4 Order code 71039492

      Kit Sub PCB Status input HE

      53/55/8X HE = harsh environment

  • 5
    • Nr 5 Order code 50096836

      Kit Sub PCB Relay out

      53/55/83/84/93/8CN/8DF

    • Nr 5 Order code 50096836

      Kit Sub PCB Relay out

      53/55/83/84/93/8CN/8DF

    • Nr 5 Order code 71039491

      Kit Sub PCB Relay out HE

      53/55/83/84/8CN/8DF HE = Harsh environment

    • Nr 5 Order code 71039491

      Kit Sub PCB Relay out HE

      53/55/83/84/8CN/8DF HE = Harsh environment

  • 6
  • 37
  • E
  • J
    • Nr J Order code 50096755

      Kit display modul Wall enclosure

      53/55/83/84/93/8CN/8DF

  • G
  • 21
  • H
  • 19
    • Nr 19 Order code 50098637

      Kit connec. board PMASS8X wall enclo

    • Nr 19 Order code 71039493

      Kit connec. board 8X wall enclosur HE

      HE = harsh environment

  • 18
  • A
    • Nr A Order code 50098705

      Kit connection board 8X FS

      Sensor: A/I/M/F/H/E/S/P/O/X

    • Nr A Order code 71039494

      Kit connection board 8X FS HE

      Sensor: A/I/M/F/H/E/S/P/O/X HE = harsh environment

    • Nr A Order code 50098706

      Kit connection board 8X FS Ex

      Sensor: A/I/M/F/H/E/S/P/O/X

    • Nr A Order code 71039495

      Kit connection board 8X FS HE EX

      Sensor: A/I/M/F/H/E/S/O/X, HE = harsh environment

  • 29
  • 30
  • 1
  • S
    • Nr S Order code 71003952

      Kit S-Dat Promass 83/8ME programmed

      Serialnumber is forceful required

  • 17
  • 8
  • 32
  • 9
  • 33
  • 10
    • Nr 10 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

    • Nr 10 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

  • 34
  • 35
  • 15
  • 12
  • 14
  • 36
  • 13
  • 16
  • 20
  • 11
  • 23
    • Nr 23 Order code 50098701

      Kit Part 8X Stainless housing comp.

      Sensor: A/I/M/F/H/S/P

  • 22
    • Nr 22 Order code 50098702

      Kit Part 8X fieldhousing compact

      Sensor: A/I/M/F/H/S/P/O

  • 24
    • Nr 24 Order code 50098704

      Kit housing gaskets FS

      Sensor: A/I/M/F/H/E/S/P/C/O/X

  • 28
    • Order code 83XXX-

      Promass 83, transmitter

    • Order code DK8SO-

      Promass 83, software package

      Chip for release of software functionality. Note: The license is locked to a specific serial number (S-DAT).

    • Order code DK8WM-

      Transmitter 80/83/84, mounting set

  • Ersättare