

- F
- L
- E
- X
Version with aluminium terminal head TA30A, 20° angle, DN25, 1 ", outside pipe ⌀ 33.7 mm

- F
- L
- E
- X
Mounting on the outer pipe wall: elimination of leakages, process contamination, flow disturbance

- F
- L
- E
- X
Version with explosion-proof terminal head TA30H, 90° angle, DN150, 6 ", outside pipe ⌀ 168.3 mm

- F
- L
- E
- X
Version with explosion-proof terminal head TA30H, 20° angle, DN25, 1 ", outside pipe ⌀ 33.7 mm

- F
- L
- E
- X
Version with stainless steel terminal head TA30R, 20° angle, DN25, 1 ", outside pipe ⌀ 33.7 mm

- F
- L
- E
- X
Version with cable probe TST310, 20° angle, DN25, 1 ", outside pipe ⌀ 33.7 mm

- F
- L
- E
- X
Thermal coupling element with advanced geometry and heat transfer material for optimized heat transfer; stainless steel clamps for easy installation

- F
- L
- E
- X
Ideal for energy monitoring
Version with aluminium terminal head TA30A, 20° angle, DN25, 1 ", outside pipe ⌀ 33.7 mm
En överblick över specifikationer
-
Accuracy
depending on application
Class AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2 -
Response time
depending on application
-
Operating temperature range
-196 °C…400 °C (-320,8 °F...752 °F)
Applikationsområde
The non-invasive thermometer iTHERM SurfaceLine TM611 is used across all industries to measure temperature without the risk of leakage and process disruption. The device is safe and easy to install and provides the same accuracy and response time as invasive temperature measurement. A specially designed thermal coupling element provides ideal thermal conductivity to the sensor and reduces ambient influences, resulting in superior measurement performance even compared to electronic compensation.
Can be used universally in all industries
Ideal for demanding process conditions such as high flow velocities, high process pressures, highly viscous or corrosive media, abrasion, pigging or small pipe diameters
Perfect for subsequent installation for measurements in existing facilities for energy and safety monitoring
Fördelar
Measurement accuracy and response time comparable with invasive measurements
No process opening required, no leakage risk
Increased safety for personnel, plant and the environment
User-friendly from product selection to installation and maintenance
Significant cost savings: shorter development and project planning times, reduced expenses for installation, certification and inspections as well as no costs for thermowells, nozzles and flanges, weld seam inspections and pipe extensions.
iTEMP temperature transmitter with all standard communication protocols and optional Bluetooth® connectivity
International certification: e.g. explosion protection according to ATEX, IECEx, CSA and NEPSI; functional safety (SIL)
Videor
-
Explore our unique product design and components
-
Comparison with invasive thermometers: accuracy and response time
-
Benefits of iTHERM SurfaceLine TM611
Extended urvalet
-
High-end produkter
- Mycket funktionella och praktiska
Tekniska egenskaper
Enkelhet

-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
Kundcase
-
Mätprincip
Resistance Temperature Detector
-
Characteristic / Application
non-invasive thermometer
cable probe or modular thermometer
suitable for high process pressures
surface mounting -
Thermowell / protection tube
without (not intended to use with thermowell)
-
Insert / probe
non exchangeable RTD or TC insert
-
Outer diameter protection tube / Insert
Geometry of coupling element is designed according to diameter of process piping
-
Process connection
surface mounting
-
Operating temperature range
-196 °C…400 °C (-320,8 °F...752 °F)
-
Accuracy
depending on application
Class AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2 -
Response time
depending on application
-
Integration head transmitter
yes (4 … 20 mA; HART; iO-Link, PROFINET, PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex - approvals
ATEX IECEx Ex tb, Ex ia, Ex db
CSA C/US IS, NI
UKCA Ex tb, Ex ia, Ex db -
Certification
SIL, MID, Marine
Välj från de föreslagna alternativen
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individuella konfiguratorn för att fortsätta.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Letar du efter fler tillval? Använd den individuella konfiguratorn för att fortsätta.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD-ritningar CAD-ritningar
- CAD-ritningar
-
Pris per del
-
<%range%><%price%>
-
- Valbara tillägg
Individuell konfigurering
Köps ofta tillsammans
Tillbehör
Vi värdesätter din integritet
Vi använder cookies för att förbättra din användarupplevelse, samla in statistik för att optimera webbplatsens funktionalitet och leverera skräddarsydda annonser eller innehåll.
Välj "Acceptera alla", för att samtycka till vår användning av cookies.
För mer information se vår Cookie Policy .