Unsurpassed reliability, accuracy and long-term stability in critical processes. The remote configurable transmitter transfers and monitors converted signals from RTD sensors and thermocouples as well as from resistance and voltage signals using selectively HART®, FOUNDATION Fieldbus™-, PROFIBUS® PA-communication. It visualizes the signals on its own backlit display. A field housing allows a direct connection in harsh process areas as well as in hygienic applications as option.
Universal input usable for resistance thermometer (RTD), thermocouple (TC), resistance thermometer (Ω), voltage transmitters (mV)
HART® protocol for converting various input signals to a scalable 4 to 20 mA analog output signal. Operating the transmitter using handheld terminals Field Xpert SFX350/370, field communicator 475 or remotely via PC
FOUNDATION Fieldbus™ ITK 6.1.2
PROFIBUS® PA Profile 3.02
Optional: stainless steel housing for hygienic or Ex d application
Fördelar
High reliability in harsh industrial environments due to dual compartment housing and compact, fully potted electronics
Backlit display with large measured value, bar graph and status condition indication
Diagnostics information according to NAMUR NE107
International approvals such as FM, CSA (IS, NI, XP and DIP) and ATEX (Ex ia, Ex nA nL, Ex d and dust ignition-proof); marine approval
SIL certification as per IEC 61508:2010
Galvanic isolation 2 kV (sensor input / current output)
Since the temperature of compressed hydrogen increases with expansion during filling, temperature measurement is essential at hydrogen filling stations for safety reasons.
Vår beröringsfria temperaturgivare kan enkelt eftermonteras på ett befintligt rör och integreras i styrsystemet för effektiv standby-drift av en turbogeneratorsats.
Den beröringsfria temperaturgivaren iTHERM SurfaceLine TM611 mäter temperatur snabbt och exakt och optimerar värmeväxlarens prestanda och verkningsgrad.
The Ziegler-Natta process uses hazardous chemicals like titanium tetrachloride. Precise temperature measurement is crucial to prevent runaway reactions and ensure safety and efficiency.
UL rec. Comp (HART) marine approval only for HART-protocol SIL2/3 only for HART-protocol ATEX Ex ia, Ex d, Ex tb, Ex ic, Ex nA ATEX IECEx Ex tb IECEx Ex ia, Ex d, Ex tb CSA IS, NI, XP, DIP CSA General Purpose FM IS, NI, XP, DIP FM+CSA XP,DIP, IS, NI INMETRO Ex ia, Ex db, Ex tb NEPSI Ex ia, Ex nA, Ex d EAC Ex ia, Ex d UKCA Ex db, Ex ia, Ex nA
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Vi använder cookies för att förbättra din användarupplevelse, samla in statistik för att optimera webbplatsens funktionalitet och leverera skräddarsydda annonser eller innehåll.
Välj "Acceptera alla", för att samtycka till vår användning av cookies.
För mer information se vår Cookie Policy .