                  Specs at a glance
- 
                              Max. measurement errorAcoustic density: ±0.01g/cm³ 
 Temperature: ±0.5K
 Sound velocity: +-2m/s
- 
                              Measuring rangeConcentration According to concentration app data sheet, maximum 0 to 100 % 
 Sound velocity 600 to 2000 m/s
 Temperature maximum 0 to +100 °C (32 to +212 °F)
 Acoustic Density 0.7 to 1.5 g/cm³
- 
                              Medium temperature range0 to 100 °C (32 to 212 °F) 
- 
                              Process temperature0 to 100 °C (32 to 212 °F) 
- 
                              Max. process pressuremax. 16 bar at 20 °C (232 psi at 68 °F) 
- 
                              Process pressuremax. 16 bar at 20 °C (232 psi at 68 °F) 
- 
                              Wetted materialsStainless steel 1.4571 (316 Ti), others on request 
Field of application
The insertion measuring device Teqwave I was developed for accurate real-time liquid analysis in vessels and larger pipes. Dedicated to in situ concentration measurement, Teqwave monitors various measuring parameters at once, and thus reduces operational expenditure. Match your Teqwave transmitter perfectly to your production needs: You can flexibly define and extend your application range.
- The acoustic waveguide measures precisely and reliably, even the smallest changes are detected 
- Continuous concentration measurement of liquids in vessels or large pipes. 
Device properties
- Insertion length: 180 mm (7 in) or 500 mm (20 in) 
- Accurate and independent of flow profile 
- Industry-compliant, easy installation via DIN rail 
- 3.5" TFT color touch screen or LED indication 
- 4-20 mA, Modbus TCP 
Benefits
- Easy and efficient – real-time in situ liquid analysis 
- Full transparency – constant monitoring of product quality without sampling 
- Highest process safety – reliable metering due to robust, maintenance-free sensor 
- Cost-saving – fewer measuring points due to multivariable measurement 
- Customized usage – innovative application concept, expendable for changing measuring tasks 
- Simplified process control – user-friendly operation and clear status visualization 
- Local data backup – integrated data storage for measured values up to 7,5 years 
Xpert selection
- 
        Specialized products 
- Designed for demanding applications
Technical excellence
Simplicity
Variable
 
                              - 
        Standard products 
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
- 
        Specialized products 
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity | 
|---|---|---|
| 
 Fundamental selection Meet your basic measurement needs | Technical excellence | Simplicity | 
| 
 Lean selection Handle your core processes easily | Technical excellence | Simplicity | 
| 
 Extended selection Optimize your processes with innovative technologies | Technical excellence | Simplicity | 
| 
 Xpert selection Master your most challenging applications | Technical excellence | Simplicity Variable | 
- 
                        - 
                                                            Technical Information (TI)
 Teqwave F/I Technical InformationMeasuring device with surface acousticwave technology 
 Smart, flexible concentration measuring device – individually for your
 processEN 10/09/201906/11/2017Language: English Version: 10/09/2019 File size: 1.7 MB File name: TI01381DEN_0219.pdf 
- 
                                                            
- 
                        - 
                                                            Operating Instruction (BA)
 Teqwave F/I Modbus TCP Operating InstructionsMeasuring device with acoustic surface wave technology EN 10/09/201906/11/2017Language: English Version: 10/09/2019 File size: 2.1 MB File name: BA01823DEN_0219.pdf 
- 
                                                            
- 
                        - 
                                                            Short Instruction (KA)
 Teqwave F/I Brief Operating InstructionsDevice with acoustic surface wave technology EN 10/09/201906/11/2017Language: English Version: 10/09/2019 File size: 1.7 MB File name: KA01371DEN_0219.pdf 
- 
                                                            
- 
                        - 
                                                            Installation Instructions (EA)
 Replacing the connection cableTeqwave F, I, T, H EN 26/03/202101/12/2017Language: English Version: 26/03/2021 File size: 526.9 KB File name: EA01229DA2_0221.pdf 
- 
                                                            
- 
                        - 
                                                            Special Documentation (SD)
 UKCA markingFlow, density, concentration, viscosity EN 04/11/202201/10/2021Language: English Version: 04/11/2022 File size: 357.4 KB File name: SD02752DEN_0222-00.pdf 
- 
                                                            
- 
                        - 
                                                            Special Documentation (SD)
 SD TeqwaveEAC Special Documentation EN 04/08/202517/09/2024Language: English Version: 04/08/2025 File size: 859.7 KB File name: SD03317DEN_0225-00.pdf 
- 
                                                            
- 
                        - 
                                                            Special Documentation (SD)
 Concentration App QuestionaireConcentration App 
 QuestionaireEN 14/11/202412/09/202421/06/202229/05/201905/03/2018Language: English Version: 14/11/2024 File size: 496.5 KB File name: SD02148DEN_0624-00.pdf 
- 
                                                            
- 
                        - 
                                                            Case Study (CS)
 Messbar und testbar: Monitoring mit TeqwaveBorer Chemie AG vertraut auf Endress+Hauser für 
 effiziente BauteilreinigungLanguage: German Version: 13/01/2023 File size: 1.5 MB File name: CS01770D06DE0122_Borer_Chemie_221129.pdf 
- 
                                                            
- 
                        - 
                                                            Case Study (CS)
 Optimiertes Reinigen für maximale Produktqualitätthyssenkrupp misst Reinigerkonzentrationen mit Teqwave I Language: German Version: 07/01/2022 File size: 2.3 MB File name: CS01612DDE_0221.pdf 
- 
                                                            
- 
                        - 
                                                            Case Study (CS)
 Optimized cleaning for maximum product qualitythyssenkrupp measures cleaner concentrations with Teqwave I Language: English Version: 07/01/2022 File size: 2.3 MB File name: CS01612DEN_0221.pdf 
- 
                                                            
 
                                             
                                     
                                     
                                     
                                     
                                     
                                  %20with%20flange%20connections%20for%20process%20applications%20-%20PP01.jpg) 
                                   
                                   
                                   
                                  %20with%20flange%20connections%20for%20process%20applications%20-%20PP01.jpg)