Omnigrad S TAF16
High temperature TC thermometer
Applicable for cement production, steel treatment, incinerators and fluidized bed furnaces
Measuring points with extremely high process temperatures require these special thermometers with ceramic or metal thermowells as well as thermocouples made from special metals, such as platinum and rhodium. The thermowell made from special materials protects from mechanical and chemical damages in the process and increases the life span of the used sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.
-
Fördelar
Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance
Long term stable measurement due to sensor protection with non-porous materials
Flexible product selection by modular design
Optimized life cycle costs by...
-
Applikationsområde
Applicable for cement production, steel treatment, incinerators and fluidized bed furnaces. The TAF16 contains a single or double TC insert and a metal or ceramic protection tube.
Process temperatures: up to +1700 °C (+3092 °F)
Dokumentation / manualer / programvara
-
Omnigrad S TAF11, TAF12x, TAF16
Technical information
High temperature assemblies
With metal or ceramic thermowells
Adjustable process connection
Thermocouple sensor types J, K, N, R, S, BTeknisk information (TI) -
perspectives Primaries 2012
Safety for the primary industry
Kundtidning (CM)12/12Engelska -
perspektiven "Grundstoffe" 2012
Lösungen für die Grundstoff-Industrie
Kundtidning (CM)11/12Tyska -
Trait d'union 56 - Edition Process
Le Journal d'Information Endress+Hauser France
Kundtidning (CM)06/13fr -
温度测量
过程工业用温度传感器和温度变送器
Verksamhetsområden (FA)12/14Kinesiska -
Pomiar temperatury
Czujniki i przetworniki pomiarowe
do kontroli przemysłowych procesów technologicznychVerksamhetsområden (FA)10/14Polska -
Измерение температуры
Датчики температуры и преобразователи для любых
отраслей промышленности.Verksamhetsområden (FA)06/13Ryska -
Mesure de température
Capteurs et transmetteurs pour les industries de process
Verksamhetsområden (FA)04/18fr -
Misura della temperatura
Termometri e trasmettitori
per l'industria di processoVerksamhetsområden (FA)04/18Italienska -
Catálogo medición temperatura
Termómetros y transmisores para la industria de proceso
Verksamhetsområden (FA)04/18Spanska -
Temperature measurement
Thermometers and transmitters for the process industry
Verksamhetsområden (FA)04/18Engelska -
Temperaturmesstechnik
Thermometer und Transmitter für die Prozessindustrie
Verksamhetsområden (FA)04/18Tyska -
Temperature measurement
Thermometers and transmitters for the process industry
Verksamhetsområden (FA)03/19Engelska -
Temperaturmesstechnik
Thermometer und Transmitter für die Prozessindustrie
Verksamhetsområden (FA)03/19Tyska -
Catálogo Medición de Temperatura
Termómetros y transmisores para la industria de proceso
Verksamhetsområden (FA)03/17Spanska -
Field of activities FA Temperature measurement
Thermometers and transmitters for the process industry
Verksamhetsområden (FA)03/13Engelska -
Sıcaklık Ölçümü
Proses endüstrisi için termometreler ve transmiterler
Verksamhetsområden (FA)03/13Turkiska -
Измерение температуры
Ключевые особенности термометров Endress+Hauser для нефтегазовой отрасли
Kompetensbroschyr (CP)08/11Ryska -
Инженерные решения по термометрии
Специальные решения по термометрии для химической и
нефтеперерабатывающей промышленностиKompetensbroschyr (CP)04/10Ryska -
Inspection test plan - TAF1X_Thermocouples
Inspection test plan - TAF1X_Thermocouples
Company certificates03/08Engelska -
Process TC Heavy duty
Produktkod: TAF16-
Deklarationsnummer: HE_00487_01.17
illverkaren Specifikation: RoHSManufacturer DeclarationEngelska -
RTD-thermometer, Process TC Heavy duty, Process TC General purpose, Process TC Explosion proof, Process TC direct in contact, Process TC Direct contact, Process RTD Hygienic, Process RTD Heavy duty, Process RTD General purpose, Process RTD Explosion proof, Process RTD direct in contact, Process RTD Direct contact, Plugs RTD direct contact, Magphant, Low cost RTD General purpose, Industrial Modular Thermometer
Produktkod: TR15-, TR13-, TR12-, TR11-, TR10-, TMT470L-, TMT162R-, TMT162C-, TMT142R-, TMT142C-, TMR35L-, TMR35-, TMR31L-, TMR31-, TM411-, TM401-, TH56-, TH55-, TH54-, TH53-, TH52-, TH51-, TR24-, TTR35-, TTR31-, TST90-, TST602-, TST487-, TST434-, TST41N-, TST414-, TST410-, TST40N-, TST310-, TST187-, TSM487-, TSM187-, TSC310-, TR88-, TR66-, TR65-, TR63-, TR62-, TR61-, TR25-, TH27-, T55-, T54-, T53-, T15-, T14-, T13-, OTR96-, OTR95-, OTR94-, OTR93-, OTR92-, OTR91-, OTR90-, OTR35-, OTR31-, MLTTS01-, MLTTS00-, GPTL-, DTT35L-, DTT35-, DTT31L-, DTT31-, TAF11-, TH18-, TH17-, TH15-, TH14-, TH13-, TH12-, TH11-, TEC420-, TC88-, TC66-, TC65-, TC63-, TC62-, TC61-, TC15-, TC13-, TC12-, TC10-, TAF16-, TAF12T-, TAF12S-, TAF12D-
Deklarationsnummer: EC_00568_01.17EU DeclarationTyska , Engelska , fr -
Process RTD General purpose, Process RTD Heavy duty, Process RTD Hygienic, Process TC Direct contact, Process TC General purpose, Process TC Heavy duty, Low cost RTD General purpose, Process RTD Direct contact
Produktkod: TR10-, TR11-, TR12-, TR13-, TR15-, TR24-, TR25-, TR44-, TR45-, TR46-, TR47-, TR48-, TR61-, TR62-, TR63-, TR65-, TR66-, TR88-, TST434-, TM412-, TAF11-, TAF12D-, TAF12S-, TAF12T-, TAF16-, TC10-, TC12-, TC13-, TC15-, TC61-, TC62-, TC63-, TC65-, TC66-, TC88-, TEC420-, TM401-, TM402-, TM411-, TST40N-, TST41N-
Deklarationsnummer: EC_00136_01.16EU DeclarationTyska , Engelska -
ACCESSORIES: TC INSERT, Process TC direct in contact, Process TC General purpose, Process TC Heavy duty
Produktkod: TSC310-, TPC300-, TPC100-, TEC300-, TC88-, TC66-, TC65-, TC63-, TC62-, TC61-, TC15-, TC13-, TC12-, TC10-, TAF16-, TAF12T-, TAF12S-, TAF12D-, TAF11-
Region: Russia (TR CU)
Certifieringsorgan: EAC
Godkännande, Nr.: TC RU D-DE.AZ01.B.01156MiscellaneousRyska -
ACCESSORIES: TC INSERT, Process TC Direct contact, Process TC direct in contact, Process TC General purpose, Process TC Heavy duty
Produktkod: TSC310-, TPC300-, TPC200-, TPC100-, TEC420-, TEC300-, TC88-, TC66-, TC65-, TC63-, TC62-, TC61-, TC15-, TC13-, TC12-, TC10-, TAF16-, TAF12T-, TAF12S-, TAF12D-, TAF11-
Region: Russia
Certifieringsorgan: Rosstandart
Godkännande, Nr.: IT.C.32.004.A_66573MetrologyRyska
Tillbehör / reservdelar
-
-
Order code 71389488
-
Order code 71389497
-
Order code 71389508
-
Order code 71389514
-
Order code
Terminal head only on request
-
Order code 60000516
Stop Flange adjustable,DIN EN 50446,23mm
Maximum temperature 400 oC. Material cast iron. Counter flangeand gasket not provided. No gas-tight connection. Dimension: d2=23 mm, a=90 mm, c=70 mm. Clampable diameter from 21mm to 22mm.
-
Order code 60008385
Stop Flange adjustable DIN EN 50446 16mm
Maximum temperature 400 oC. Material cast iron. Mating flange and gasket not provided. No gas-tight connection. Dimension: d2=16 mm, a=75 mm, c=55 mm. Clampable diameter from 14mm to 15mm.
-
Order code 60020836
Compression fitting G 3/4", 22,5mm
Maximum temperature 350 oC. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameters 21.3/22mm. Dimension: A=G 3/4", d=22.5 mm, Wr=41.
-
Order code 60021425
Compression fitting G1 1/2", 22.5mm
Maximum temperature 350 oC. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameters 21,3/22mm. Dimension: A=G 1 1/2", d=22,5 mm, Wr=55.
-
Order code 60021757
Compression fitting G 1", 22,5mm
Maximum temperature 350 oC. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameters 21,3/22mm. Dimension: A=G 1", d=22,5 mm, Wr=41.
-
Order code 71001827
Compression fitting G1" d28 316Ti
Maximum temperature 350 oC. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameters 26,7/27mm. Dimension: A=G 1", d=28mm, Wr=46.
-
Order code 71031438
Compression fitting G3/4" d15,5 316Ti
Maximum temperature 350oC. Maximum pressure 1 bar. Material 316Ti (1.4571) For Pipe diameter 13,7/14/15 mm. Dimension: A=G 3/4",d=15.5 mm, Wr=36.
-
Order code 71039792
Stop Flange adjustable,DIN EN 50446,29mm
Maximum temperature 400 oC Material cast iron. Counter flange and gasket not provided. No gas-tight connection. Dimension: d2=29mm, a=90mm, c=70mm. Clampable diameter from 27mm to 28mm.
-
Order code 71125353
Compression fitting G 1 1/4", 29mm
Maximum temperature 350 oC. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameter 28mm. Dimension: A=G 1 1/4", d=29mm, Wr=55.
-
Order code 71125354
Compression fitting G11/2", 29mm
Maximum temperature 350 oC. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameters 28mm. Dimension: A=G 1 1/2", d=29mm, Wr=55.
-
Order code 71125362
Compression fitting G3/4",19mm
Maximum temperature 350 oC. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameter 18mm. Dimension: A=G 3/4", d=19mm, Wr=36.
-
Order code 71125364
Compression fitting G1", 19mm
Maximum temperature 350 oC. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameter 18mm. Dimension: A=G 1", d=19mm, Wr=41.
-
Order code 71244062
Compression fitting G 1/2" 15,5mm 316Ti
-
Order code 71244070
Compression fitting G 1/2" 17,5mm 316Ti
-
Order code 71421272
Compression fitting G1" 15.5.mm, 316Ti
-
Order code 71182602
-
Order code 71044061
Fixing kit cpl.TMT82/85/84 (european)
2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector
-
Order code TPC100-
-
-
-
Nr B Order code TMT181-
iTEMP TMT181, Head Transmitter PCP
Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
-
Nr B Order code TMT84-
iTEMP TMT84, Transmitter PA
Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.
-
Nr B Order code TMT85-
iTEMP TMT85, Transmitter FF
Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.
-
-
-
Order code FXA195-
Commubox FXA195
Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.
-
Order code TXU10-
Configuration kit TXU10-
for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.
-
Order code READWIN-
Readwin 2000 Operation + Read. software
-
-
-
Nr B Order code TMT182-
iTEMP TMT182, Head Transmitter HART
Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
-
Nr B Order code TMT82-
iTEMP TMT82, Transmitter HART
2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.
-
-
-
Order code 71244071
Compression fitting G 3/4" 18mm 316Ti
-