Dissolved oxygen transmitter
Liquisys COM253

Dissolved oxygen transmitter 
Liquisys COM253 ©Endress+Hauser

Compact field device for water, wastewater, utilities and fish farming

Liquisys COM253 is a standard transmitter for use with COS41 and COS61 oxygen sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and calibration make configuration and operation fast and easy.

  • Fördelar

    • More operational safety: Continuous process check system, customized alarm configuration, calibration plausibility check.

    • Reliable oxygen control: Current input for flow rate monitoring with controller shut off or for feedforward control.

    • Easy to operate...

  • Applikationsområde

    The Liquisys COM253 transmitter works with Oxymax COS41 and Oxymax COS61 dissolved oxygen sensors in environmental applications, such as:

    • O2 control in the aeration basin

    • O2 control and monitoring of drinking water

    • Surface water monitoring

    • Process...

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Sensor Oxygen

  • Application

    Water, Waste water, process, fish farming

  • Characteristic

    4-wire transmitter with graphic display.

  • Design

    Dissolved oxygen transmitter in a field housing made of PC/ABS for COS31/41/71.

  • Material

    PC/ABS-housing

  • Dimension

    247x170x115mm
    (9.63x6.63x4.48inch)

  • Temperature sensor

    Display and current output.

  • Input

    1-channel transmitter.

  • Output

    0/4-20mA, Hart, Profibus.

  • Additional certifications

    CSA Gen. Purpose.

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification
    • Order code 51500320

      Kit CXM2X3 Relaismod. 2rel

      Upgrade of LIQUISYS-M basis version by 2 floating changeover contacts.

  • 290
    • Nr 290 Order code 51511446

      KIT CXM2X3 relay mod. 2rel / CSA

      Upgrade of LIQUISYS-M basis version by 2 floating changeover contacts.

  • 300
    • Nr 300 Order code 51500321

      Kit CXM2X3 Relaismodule 4rel

      Upgrade of LIQUISYS-M basic version by 4 floating changeover contacts.

    • Nr 300 Order code 51511447

      KIT CXM2X3 relay mod. 4rel / CSA

  • 290
    • Nr 290 Order code 51504304

      Kit CXM2X3 Relais Mod. 2rel.+I/CSA

      Upgrade of LIQUISYS-M basic version by 2 contacts and current input 4-20mA.

  • 300
    • Nr 300 Order code 51504305

      Kit CXM2X3 Relais Mod. 4Rel+I/CSA

      Upgrade of LIQUISYS-M basic version by 4 contacts and current input 4-20mA.

  • 40
  • 60
  • 50
  • 70
  • 80
  • 90
  • 290
    • Nr 290 Order code 71134732

      Kit CxM2x3: Relay mod. for PBDP; H/W2.1x

      Content: 1x Relay module Profibus DP 2x Relay, 1x Current input DP connection qualified from H/W 2.10

  • 250
  • 260
  • 10
  • 20
    • Nr 20 Order code 51500318

      KIT CxM2x3 power supply 24 AC/DC

      KIT CxM2x3 power supply DC

  • 410
  • 335
  • 330,340,450,
  • 260,490
  • 400
  • 430
  • 470
  • 310
    • Order code 50086842

      Post mounting kit for LIQUISYS

      for mounting the field-transmitters on horizontal or vertical pipes (max. diam. 60 mm). Material: stainless steel V2A

    • Order code 51500385

      Upgrade "Plus-Package" for LIQUISYS-M

      Upgrade of LIQUISYS-M basic version (parameter pH,Cond.,Tu,CL,O2 (WX to WS)) to S-version (plus-package). Serial number of instrument needed.

    • Order code 51501679

      Upgrade "Plus-Package" for COM 2X3

      Upgrade of Liquisys-M basic version (parameter DO (DX to DS)) to S-version (plus-package). Serial number of instrument needed.

    • Order code 51500963

      Upgrade cleaning for LIQUISYS-M

      Upgrade of LIQUISYS-M basic version by cleaning functionality (Chemoclean) (serial number of instrument needed). If not yet installed, a 4-relay board must be ordered separately (51500321).

  • Föregångare