Conductivity compact device
Smartec CLD134

Conductivity compact device
Smartec CLD134 ©Endress+Hauser
Conductivity compact device
Smartec CLD134 ©Endress+Hauser

The conductivity of a liquid can be measured using the conductive or toroidal measuring principles. This video shows what it is about and how these measuring principles work.

Toroidal conductivity measuring system for hygienic and sterile applications

Smartec CLD134 is a measuring system for inductive conductivity in the food & beverage and life sciences industries. The combination of a transmitter and a sensor is interference-free and especially easy-to-use. It meets the highest hygienic and sterile demands thanks to its food-grade virgin PEEK body, its jointless and creviceless design and its hygienic certificates. Smartec CLD134 is therefore the ideal package to ensure the highest safety and quality of your products and processes.

  • Fördelar

    • Unique hygienic design avoids recontamination

    • With all hygienic certificates required in hygienic and sterile applications

    • Certified biocompatibility according to USP class VI

    • Compliant with EG 2023/2006 and 1935/2004

    • Suitable for cleaning-in-place (CIP)...

  • Applikationsområde

    The hygienic Smartec CLD134 measures toroidal conductivity in food & beverage and life science applications:

    • Phase separation of product/water and product/product mixtures in pipe systems

    • Control of CIP processes in the return channel

    • Concentration...

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Inductive

  • Application

    Food, beverage and pharmaceutical industries and biotechnology.

  • Characteristic

    Specifically intended for use in hygienic applications and especially suitable for following applications:
    Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring.

  • Measurement range

    100 µS/cm - 2000 mS/cm
    cellconstant k : 6.31/cm

  • Measuring principle

    Inductive conductivity measurement

  • Design

    Hygienic design with FDA certified virgin PEEK body including all hygienic certifications.

  • Material

    In contact with medium: Virgin PEEK
    Surface roughness: Ra<0.9µm

  • Process temperature

    Process temperature: -10°C - 125°C
    (14°F - 257°F)
    Sterilisation: 150°C/5 bar (max. 60 min.)
    (302°F/72.5 psi)

  • Process pressure

    12 bar(174 psi)/20°C(68°F)
    8 bar(116 psi)/125°C(257°F)

  • Temperature sensor

    Pt 1000 (class A)with a temperature response time T90 < 27s.

  • Connection

    Dairy pipe, aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50.

  • Ingres protection

    IP67

  • Output

    Conductivity, concentration and temperature.0/4-20 mA, HART, Profibus

  • Additional certifications

    FDA, EHEDG, 3A, biological reactivity (USP class VI part 87 and 88)

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification
  • Föregångare