Analog disinfection sensor
CCS141

Analog disinfection sensor ©Endress+Hauser

Trace sensor for drinking and industrial water treatment

CCS141 is the analog sensor for trace measurement of free chlorine. It delivers reliable values even if fluctuations in flow or conductivity occur and allows control of the disinfection loop so that the water is free of germs. At the same time, the sensor is designed for long calibration and service intervals reducing your maintenance effort.

  • Fördelar

    • Recalibration intervals approx. 1 to 4 months under constant operating conditions

    • Easy membrane replacement thanks to prefabricated membrane cap

    • ...

  • Applikationsområde

    CCS141 measures free chlorine in:

    • Drinking water
      - Trace measurement in process water and distribution networks
      - Monitoring, control and optimization of disinfection processes

    • ...

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Free chlorine

  • Application

    Water, process

  • Characteristic

    Amperometric measurement of free chlorine.

  • Measurement range

    0,01 - 5ppm free chlorine; pH 4-8,2

  • Measuring principle

    - closed (membrane covered) measuring cell.
    - Reduction of hypochloric acid (HOCl) to chlorid on the cathode at approx. 20mV.

  • Design

    Closed amperometric 2-electrode measuring cell with PTFE membrane.

  • Material

    Sensor shaft : PVC
    Membrane : PTFE
    Membrane cap :PBT (GF30); PVDF

  • Dimension

    Diameter : appr. 25mm
    Length : 160mm

  • Process temperature

    2°C - 45°C

  • Process pressure

    0bar - 1bar

  • Temperature sensor

    With NTC-temperature sensor

  • Connection

    Fixed cable