Cubemass DCI
Coriolis flowmeter

Coriolis flowmeter - Cubemass DCI ©Endress+Hauser

The Coriolis Flow Measuring Principle

The ultra-compact sensor for smallest quantities with seamless system integration

In many applications like lacquering, surface finishing, small substance quantities have to be precisely measured or added. Whether in the laboratory applications or on test stands, whether in chemistry or in the oil sector – the lightweight all-rounder with various communication possibilities in ultra-compact design is the high pressure specialist for direct mass and density measurement. From just a few drops to 1000 kilograms an hour – Cubemass measures liquids of various densities.

  • Fördelar

    • Reduced installation cost – compact single-tube design

    • Fewer process measuring points – multivariable measurement (flow, density, temperature)

    • Space-saving installation – no in/outlet run needs

    • High flexibility in system integration – wide range of...

  • Applikationsområde

    • Measuring principle operates independently of physical fluid properties such as viscosity or density

    • For smallest quantities of liquids and gases; ideal for skid integration.

    Device properties

    • Nominal diameter: DN 1 to 6 (1/24 to 1/4")

    • Process...

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Coriolis

  • Product headline

    The ultra‐compact sensor for smallest quantities with seamless system integration. For smallest quantities of liquids and gases; ideal for skid integration.

  • Sensor features

    Reduced installation cost – compact single‐tube design. Fewer process measuring points – multivariable measurement (flow, density, temp). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi).

  • Transmitter features

    High flexibility in system integration – wide range of communication interfaces. Fast commissioning – preconfigured devices. Automatic recovery of data for servicing. Device in compact or remote version. Flexible outputs.

  • Nominal diameter range

    DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4539 (904L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm3

  • Measuring range

    0 to 1000 kg/h (0 to 37 lb/min)

  • Max. process pressure

    PN 40, Class 300, 10K, 400 bar (5800 psi)

  • Medium temperature range

    –50 to +200 °C (–58 to +392 °F)

  • Ambient temperature range

    Standard: –20 to +60 °C (–4 to +140 °F)
    Option: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium

  • Degree of protection

    IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency/switch output (passive), phase‐shifted pulse
    Relay

  • Inputs

    1 modular input: status

  • Digital communication

    HART, Modbus RS485

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    ATEX, IECEx, NEC/CEC, NEPSI

  • Other approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
    CRN

  • Mätprincip

    Coriolis

  • Product headline

    The ultra‐compact sensor for smallest quantities with seamless system integration. For smallest quantities of liquids and gases; ideal for skid integration.

  • Sensor features

    Reduced installation cost – compact single‐tube design. Fewer process measuring points – multivariable measurement (flow, density, temp). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi).

  • Transmitter features

    High flexibility in system integration – wide range of communication interfaces. Fast commissioning – preconfigured devices. Automatic recovery of data for servicing. Device in compact or remote version. Flexible outputs.

  • Nominal diameter range

    DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4539 (904L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm3

  • Measuring range

    0 to 1000 kg/h (0 to 37 lb/min)

  • Max. process pressure

    PN 40, Class 300, 10K, 400 bar (5800 psi)

  • Medium temperature range

    –50 to +200 °C (–58 to +392 °F)

  • Ambient temperature range

    Standard: –20 to +60 °C (–4 to +140 °F)
    Option: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium

  • Degree of protection

    IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency/switch output (passive), phase‐shifted pulse
    Relay

  • Inputs

    1 modular input: status

  • Digital communication

    HART, Modbus RS485

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    ATEX, IECEx, NEC/CEC, NEPSI

  • Other approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
    CRN

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

  • Material certificates

    3.1 material

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification
  • F
    • Nr F Order code 50098557

      Kit power s.b. 40/8X/65 220V REx000

      220V = 85-260VAC

    • Nr F Order code 71039431

      Kit p.s.b.40/8X 220V REx000 HE

      HE = harsh environment 220V = 85-260VAC

    • Nr F Order code 50098558

      Kit power s.b. 40/8X/65 220V REx120 Ex

      220V = 85-260VAC

    • Nr F Order code 71039432

      Kit p.s.b.8X 220V REx120 HE Ex

      HE = harsh environment 220V = 85-260VAC

    • Nr F Order code 50098565

      Kit P.s.b. 40/8X/65 24V REx000

      24V = 20-55VAC / 16-62VDC

    • Nr F Order code 71039434

      Kit p.s.b.8X 24V REx000 HE

      HE = harsh environment 24V = 20-55VAC / 16-62VDC

    • Nr F Order code 50098566

      Kit P.s.b. 40/8X/65 24V REx120 Ex

      24V = 20-55VAC / 16-62VDC

    • Nr F Order code 71039436

      Kit P.s.b. 8X 24V REx120 HE Ex

      HE = harsh environment 24V = 20-55VAC / 16-62VDC

  • 7
  • B
    • Nr B Order code 71106645

      Kit amplifier Cubemass DCI WEA Ex

      WEA= Language DE+EN+FR+IT+ES+PT+NL

    • Nr B Order code 71106647

      Kit amplifier Cubemass DCI WEA HE Ex

      WEA= Language DE+EN+FR+IT+ES+PT+NL HE = harsh environment

    • Nr B Order code 71106649

      Kit amplifier Cubemass DCI EES Ex

      EES= Language SV+FI+NO+RU+PL+CS+EN

    • Nr B Order code 71106652

      Kit amplifier Cubemass DCI EES HE Ex

      EES= Language SV+FI+NO+RU+PL+CS+EN HE = harsh environment

    • Nr B Order code 71106653

      Kit amplifier Cubemass DCI SEA Ex

      SEA= Language JA+ID+EN

    • Nr B Order code 71106655

      Kit amplifier Cubemass DCI SEA HE Ex

      SEA= Language JA+ID+EN HE = harsh environment

    • Nr B Order code 71106656

      Kit amplifier Cubemass DCI CN Ex

      CN= Language ZH + EN

    • Nr B Order code 71106657

      Kit amplifier Cubemass DCI CN HE Ex

      CN= Language ZH + EN HE = harsh environment

  • C
    • Nr C Order code 50098302

      Kit commodul Iout passive/Frequency Exi

      50/53/40/8X/93/65

    • Nr C Order code 71039479

      Kit I/O Iout passive/Frequency HE Exi

      50/53/8X HE = harsh environment

    • Nr C Order code 50098303

      Kit commodul Iout active/Frequency Exi

      50/53/40/8X/93/65

    • Nr C Order code 71039478

      Kit I/O Iout active/Frequency HE Exi

      50/53/8X HE = harsh environment

  • D
    • Nr D Order code 71021743

      Kit Com ModbusRS485+stat.In 2Interf.Ex

      53/83/84/65/8CN/8DF

    • Nr D Order code 71039485

      Kit I/O Modb.RS485+Stat.In 2Interf.HE EX

      53/83/84/8CN/8DF HE = Harsh environment

    • Nr D Order code 50096833

      Kit Commodul current out 3 Interface Ex

      53/55/8X/93/65

    • Nr D Order code 71039477

      Kit I/O current out 3 Interface HE EX

      53/55/8X HE = harsh environment

  • 2
    • Nr 2 Order code 50096834

      Kit Sub PCB current out

      53/55/8X/93/65

    • Nr 2 Order code 71039487

      Kit Sub PCB current out HE

      53/55/8X HE = harsh environment

  • 5
    • Nr 5 Order code 50096836

      Kit Sub PCB Relay out

      53/55/83/84/93/8CN/8DF

    • Nr 5 Order code 50096836

      Kit Sub PCB Relay out

      53/55/83/84/93/8CN/8DF

    • Nr 5 Order code 71039491

      Kit Sub PCB Relay out HE

      53/55/83/84/8CN/8DF HE = Harsh environment

    • Nr 5 Order code 71039491

      Kit Sub PCB Relay out HE

      53/55/83/84/8CN/8DF HE = Harsh environment

  • 4
    • Nr 4 Order code 50096837

      Kit Sub PCB Status input

      53/55/8X/93/65

    • Nr 4 Order code 71039492

      Kit Sub PCB Status input HE

      53/55/8X HE = harsh environment

  • 31
    • Nr 31 Order code 50108692

      Kit Sub PCB 84/8CN/8DF frequency out

    • Nr 31 Order code 50108692

      Kit Sub PCB 84/8CN/8DF frequency out

    • Nr 31 Order code 71039490

      Kit Sub PCB 84/8CN/8DF frequency out HE

      HE = harsh environment

    • Nr 31 Order code 71039490

      Kit Sub PCB 84/8CN/8DF frequency out HE

      HE = harsh environment

  • J
    • Nr J Order code 50096755

      Kit display modul Wall enclosure

      53/55/83/84/93/8CN/8DF

  • E
  • G
  • 21
  • 18
  • 19
    • Nr 19 Order code 50098637

      Kit connec. board PMASS8X wall enclo

    • Nr 19 Order code 71039493

      Kit connec. board 8X wall enclosur HE

      HE = harsh environment

  • A
    • Nr A Order code 50098705

      Kit connection board 8X FS

      Sensor: A/I/M/F/H/E/S/P/O/X

    • Nr A Order code 71039494

      Kit connection board 8X FS HE

      Sensor: A/I/M/F/H/E/S/P/O/X HE = harsh environment

    • Nr A Order code 50098706

      Kit connection board 8X FS Ex

      Sensor: A/I/M/F/H/E/S/P/O/X

    • Nr A Order code 71039495

      Kit connection board 8X FS HE EX

      Sensor: A/I/M/F/H/E/S/O/X, HE = harsh environment

  • 29
  • 30
  • 1
  • S
    • Nr S Order code 71003953

      Kit S-Dat Promass 84/8CN/8DF programmed

      Serialnumber is forceful required

  • 8
  • 32
  • 10
    • Nr 10 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

    • Nr 10 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

    • Nr 10 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

    • Nr 10 Order code 71247838

      Repair kit cover, remote version

      Usage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease

    • Nr 10 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

  • 34
  • 35
  • 15
  • 12
  • 14
  • 36
  • 13
  • 20
  • 11
  • 25
    • Nr 25 Order code 50098703

      Kit Part 40/8X fieldhousing compact

      Sensor: E/F-HT/X

  • 26
  • 24
    • Nr 24 Order code 50098704

      Kit housing gaskets FS

      Sensor: A/I/M/F/H/E/S/P/C/O/X

  • 28
    • Order code 71123816

      Mounting plate Cubemass packed

      Universal mounting plate for fixing the flowmeter to various surfaces, such as walls, switchboards etc.

    • Order code DK8WM-

      Transmitter 80/83/84, mounting set

    • Order code DK8CS-

      Cubemass, mounting kit

      Adapters for different process connection standards. To be connected to the Cajon couplings.

    • Order code FXA193-

      Serviceinterface FXA193

      The service interface connects the service port of Proline and ToF devices with the serial interface RS 232C (9 pin.) of a personal computer. Contents of delivery: - Serviceinterface with RS 232C connection cable (9 pin.) - FXA "USB" cable, the additional power supply for FXA193 from USB-port of the PC.

  • Ersättare