Proline Prosonic Flow
E 100 Ultrasonic flowmeter
Economical Ultrasonic flowmeter with integrated temperature measurement
Measuring of demineralized water in utilities, for example in boiler condensate return lines, requires reliable devices. Prosonic Flow E 100 provides economical and accurate bidirectional flow measurement across all industries. With its integrated temperature measurement, Prosonic Flow E 100 proves to be a multivariable flowmeter for considerable additional value in your plant. Heartbeat Technology ensures compliance at all times.
-
Fördelar
Long-term stability – reliable, robust sensor
Reducing further measuring point – multivariable device
Dependable flow measurement – high turndown (200:1)
Time-saving local operation without additional software and hardware – integrated web server
Extended...
-
Applikationsområde
The measuring principle is independent of pressure, density, temperature and conductivity
Bidirectional measuring of demineralized water applications for utilities, e.g. boiler condensate return lines
Device properties:
Measuring accuracy up to 0.5% for...
Dokumentation / manualer / programvara
-
Proline Prosonic Flow E 100
Technical Information
Ultrasonic transit time flowmeter
Economical Ultrasonic flowmeter with integrated temperature measurementTeknisk information (TI) -
Proline Prosonic Flow E 100
HART
Operating Instructions
Ultrasonic time-of-flight flowmeter
Bruksanvisning (BA) -
Proline Prosonic Flow 100
HART
Description of Device Parameters
Ultrasonic time-of-flight flowmeter
Enhetsparameter (GP) -
Proline 100
HART
Brief Operating Instructions
Transmitter with ultrasonic time-of-flight sensor
Short Instruction (KA)12/17Engelska -
Proline Prosonic Flow E
Brief Operating Instructions
Proline Prosonic Flow E
Ultrasonic time-of-flight sensorShort Instruction (KA)12/17Engelska -
Replacing Spare Parts
Installation Instructions
Promag, Promass 100, CNGmass, LNGmass, LPGmass, Promag 400 Index C,
Promag, Promass 300, 500, 500-digital, Prosonic Flow E 100, Pros
onic Flow E Heat, Prosonic Flow 300, 500-digialMonteringsanvisning (EA) -
Small parts
Installation Instructions
Promag, Promass 100, 500, CNGmass, LNGmass, LPGmass, Promag 400 Index C,
Prosonic Flow E 100, Prosonic Flow E Heat, Prosonic Flow 50
0-digitalMonteringsanvisning (EA) -
Replacing the Electronics Module
Installation Instructions
Prosonic Flow E 100, Prosonic Flow E Heat
Monteringsanvisning (EA) -
Activating application packages
Installation Instructions
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150Monteringsanvisning (EA) -
Replacing Display module, non Ex, Zone 2, Class 1 Div. 2
Installation Instructions
Promass 100, Promag 100, Prosonic Flow E 100
Monteringsanvisning (EA) -
Proline Prosonic Flow 100
HART
Heartbeat Verification + Monitoring application package
Special Documentation
Ultrasonic time-of-flight flowmeter
Specialdokumentation (SD) -
Proline Prosonic Flow E 100
Das wirtschaftliche Ultraschall-Durchflussmessgerät mit integrierter
TemperaturmessungInnovationer (IN)11/17Tyska -
Proline Prosonic Flow E 100
Le débitmètre à ultrasons économique avec mesure de température intégrée
Innovationer (IN)11/17fr -
Proline Prosonic Flow E 100
The economical ultrasonic flowmeter with integrated temperature
measurementInnovationer (IN)11/17Engelska -
Prosonic Flow E100
Ultraschall Durchflussmessgerät zur Messung von Wasser und
wasserähnlichen
Flüssigkeiten mit integrierter Temperaturmessung.Anbudstext03/18Tyska -
EDD Single, AMS11_HART_FL_ProsonicFlow100_0x115C_0x01_0x02, 22.11.2018 (Flow, Prosonic Flow 100, 0x
HART,
AMS Version: 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_ProsonicFlow100_0x115C_0x01_0x01, 14.12.2017 (Flow, Prosonic Flow 100, 0x11
HART,
Experion Version: R432.1
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_ProsonicFlow100_0x115C_0x01_0x02, 22.11.2018 (Flow, Prosonic Flow 100, 0x
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, ProsonicFlow100_9E1B_CDI_FW_1_00_zz_Dev_Rev_01, 13.07.2019 (Flow, Prosonic Flow 100, 0x
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.10.0.172Language neutral -
DTM Single, ProsonicFlow100_9E1B_HART_FW_1_00_zz_Dev_Rev_01, 09.07.2019 (Flow, Prosonic Flow 100, 0
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.06.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 5.0
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.10.0.151Language neutral -
Faceplate Single, PRM_HART_FL_ProsonicFlow100_0x115C_0x01_0x01, 14.12.2017 (Flow, Prosonic Flow 100
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 25.10.2019 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
PROSONIC FLOW E
Produktkod: 9E1B-, 9EHB-
Deklarationsnummer: EC_00598_01.17EU DeclarationTyska , Engelska , fr -
PROSONIC FLOW E
Produktkod: 9E1B-, 9EHB-
Deklarationsnummer: EC_00597_01.17EU DeclarationTyska , Engelska , fr -
PROSONIC FLOW E
Produktkod: 9E1B-
Region: International
Certifieringsorgan: FieldComm GroupFieldbus ConformanceEngelska -
PROSONIC FLOW E
Produktkod: 9E1B-, 9EHB-
Region: Canada, USA
Certifieringsorgan: CSAOrdinary Location Product SafetyEngelska
Tillbehör / reservdelar
-
-
Nr 30 Order code XPD0041-
-
-
-
Nr 39 Order code 71185788
Kit T-DAT, 100/300/400/500/500 digital
Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Prosonic Flow 300, 500 digital, Promag 400(C). (C) = generation index C.
-
-
-
Nr 50 Order code XPD0023-
Display module, 4-wire, 100
Usage: Promag 100, Promass 100, Prosonic Flow E 100.
-
-
-
Nr 21 Order code 71185789
Kit cover, compact, Alu
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: Cover Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.
-
-
-
Nr 20 Order code 71266334
Kit cover, sight glass, compact, Alu
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat. Consists of: Cover with sight glass Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.
-
-
-
Nr 70 Order code 71185795
Kit housing gaskets, compact, Alu
Usage: Promass 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: O-Ring 113,90 x 3,53 NBR for cover. Gasket EPDM for housing/sensor.
-
-
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
-
-
Nr 12 Order code 71276494
Kit securing clamp, screw
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensor housing: Promag 400(C), (C) = generation index C, Promag/Promass 500, Promag/Promass/Prosonic Flow 500 digital. Consists of: cover clamp, screw M4x16.
-
-
-
Order code XPRFID-
-