Proline Promag D 400
Electromagnetic flowmeter

Electromagnetic flowmeter - Proline Promag D 400 ©Endress+Hauser

The Electromagnetic Flow Measuring Principle

Introduction of Proline Web server

Meter designed as compact wafer version with a state-of-the-art transmitter for Water & Wastewater

The wafer flowmeter Promag D is designed for all basic water applications where space is at a minimum. Its innovative housing construction enables a customized and fast centering as well as a cost-optimized installation. Promag D 400 saves time and costs thanks to the broad functionality of its water- and wastewater-optimized transmitter. In addition, Heartbeat Technology ensures compliance and process safety at all times.

  • Fördelar

    • Easy, fast centering of the sensor – innovative housing construction

    • Energy-saving flow measurement – no pressure loss due to cross-section constriction

    • Maintenance-free – no moving parts

    • Safe operation – no need to open the device due to display with...

  • Applikationsområde

    • The bidirectionally measuring principle is virtually independent of pressure, density, temperature and viscosity

    • For basic water applications; optimized for limited space and plastic pipe installations

    Device properties

    • Short installation length and...

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification
  • 45
    • Nr 45 Order code 71228789

      Kit connection terminals, Promag 400(C)

      (C) = generation index C. Consists of: Connection terminal 3-Pol stamp 1,2, Connection terminal 2-Pol stamp A,B, Connection terminal 4-Pol stamp 20-23, Connection terminal 4-Pol stamp 24-26.

  • 40
    • Nr 40 Order code 71228791

      Kit connec. board, D, compact, electr.

      Usage: Promag 400(C) with sensor D. (C) = generation index C.

    • Nr 40 Order code 71228790

      Kit connec. board, D/L/W, remote,electr.

      Usage: Promag 400(C) with sensor D/L/W. (C) = generation index C.

  • 30
    • Nr 30 Order code XPD0014-

      Electronic Promag 400 Index C

      Complete main electronic module or power supply, I/O-board and amplifier as individual boards. Complete main electronic module contains: Power supply, I/O-board, amplifier, board carrier, terminal connection, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminal connection/ I/O-board incl. terminal connection/ Amplifier incl. ribbon cable.

  • 44
    • Nr 44 Order code 50098018

      Kit connection board D/E/L/P/S/W FS

      Usage: 10/50/51/53/55/400/800

  • 39
    • Nr 39 Order code 71185788

      Kit T-DAT, 100/300/400/500/500 digital

      Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Promag 400(C). (C) = generation index C.

  • 30
    • Nr 30 Order code XPD0040-

      Electronic Promag 400 Index C update

      Complete main electronic module or power supply, I/O-board with amplifier as individual boards. Complete main electronic module contains: Power supply, I/O-board, amplifier, board carrier, terminal connection, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminal connection/ I/O-board incl. terminal connection and Amplifier incl. ribbon cable.

  • 50
    • Nr 50 Order code XPD0017-

      Display module,4-wire,400 Index C

      Usage: Promag 400 Index C

  • 20
    • Nr 20 Order code 71228788

      Kit cover, polycarbonate, Promag 400(C)

      (C) = generation index C. Consists of: Cover plastic complete, O-Ring 196,44x3,53 VMQ, 2x hinge pin L= 58mm plastic.

    • Nr 20 Order code 71384170

      Kit cover, alu,Promag 400(C),500 digital

      Usage: Promag 400(C) = generation index C, Promag/Promass 500 digital, transmitter housing Alu. Consists of: cover Alu complete included O-Ring 196,44x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150.

  • 24
    • Nr 24 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

    • Nr 24 Order code 71247838

      Repair kit cover, remote version

      Usage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease

  • 25
    • Nr 25 Order code 71278077

      Kit 10 cover gasket, polycarbonate

      Usage: Promag 400(C), 500 digital with polycarbonate housing. (C) = generation index C. Consists of: 10x O-Ring 196,44x3,53 VMQ.

    • Nr 25 Order code 71278078

      Kit cover gasket, alu,400(C),500 digital

      Usage: Promag 400(C) = generation index C, Promag/Promass 500 digital, transmitter housing Alu, Ex. Consists of: 10x O-Ring 196,44x3,53 VMQ, default and -50oC/-58oF.

  • 71
    • Nr 71 Order code 71228793

      Kit housing gasket, D/L/W,compact,400(C)

      Usage: Promag 400(C) with sensor D/L/W. (C) = generation index C. Consists of: Gasket EPDM for housing/sensor D/L/W. O-Ring 29,87x1,78 HNBR for sensor- plug L/W.

  • 73
    • Nr 73 Order code 50098023

      Kit housing gasket FS Stnd/HT

      Usage: 10/50/51/53/55/400/800 Sensor: D/E/L/P/S/W

  • 12
    • Nr 12 Order code 71228794

      Kit housing parts, D/L/W, compact,400(C)

      Usage: Promag 400(C) with sensor D/L/W. (C) = generation index C. Consists of: 4x screw M5x18 hex cap DIN912 pla, 4x spring washer M5 DIN7980 st.pla, for housing/sensor.

  • 13
    • Nr 13 Order code 50098019

      Kit parts housing FS Stnd/HT

      Usage: 10/50/51/53/55/400/800 Sensor: D/E/H/L/P/S/W

  • 15
  • 17
  • 15
  • 17
  • 15
  • 17
  • 15
  • 82
    • Nr 82 Order code 71228792

      Kit display protec., 400(C)/500 digital

      Usage: Promag 400(C) = generation index C, Promag/Promass 500 digital, transmitter housing. Consists of: display protection 1.4301, installation material.

    • Order code 5X4CXX-

      Transmitter/Conversion Kit Promag 400

      Same housing for compact/remote version. Corrosion-resistant transmitter version. With an integrated web server Conversion kit: For conversion of an already existing Promag to the new device generation or to another device version. Consists of all required conversion parts.

    • Order code DK5005-

      Transmitter 400, mounting kit

    • Order code DK5CA-

      Promag, cable remote version

      10/50/51/53/55/400/800 1 kit includes 1 coil cable and 1 signal cable

    • Order code DK5DD-

      Promag D, seal set

      A set includes 2 flange seals

    • Order code DKD-

      Promag D, mounting set

      The mounting set contains threaded bolts, centering sleeves, nuts, washers and a pair of EPDM flange seals orderable separately, as replacement for M1, M2

    • Order code XPRFID-

      Spare RFID TAG

      Consists of: RFID TAG, fixing wire, crimp sleeve.