Proline Promass O 100
Coriolis flowmeter

Coriolis flowmeter - Proline Promass O 100 ©Endress+Hauser

The Coriolis Flow Measuring Principle

Introduction of Proline Web server

The robust high-pressure flowmeter with an ultra-compact transmitter

Promass O is designed for premium accuracy of liquids and gases at the highest process pressures in the oil and gas industry. The sensor is fully suitable for offshore conditions and resistant to stress corrosion cracking. Promass O 100 delivers full performance on the smallest footprint with its ultra-compact transmitter and thus enables seamless system integration. Heartbeat Technology ensures process safety at all times.

  • Fördelar

    • Maximum safety – highest resistance to stress corrosion cracking

    • Fewer process measuring points – multivariable measurement (flow, density, temperature)

    • Space-saving installation – no in/outlet run needs

    • Space-saving transmitter – full functionality on...

  • Applikationsområde

    • Measuring principle operates independently of physical fluid properties such as viscosity or density

    • For premium accuracy at highest process pressures, fully suitable for offshore conditions.

    Device properties

    • Measuring tube in 25Cr Duplex, 1.4410 (...

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification
  • 47
    • Nr 47 Order code 71185785

      Kit Ex-i barrier

      Usage: Promass 100, CNGmass, LPGmass, LNGmass.

  • 45
    • Nr 45 Order code 71185787

      Kit connection terminal for Ex-i barrier

      Usage: Promass 100, CNGmass, LPGmass, LNGmass. Consists of: 2x Connection terminal 4-Pol.

  • 30
    • Nr 30 Order code XPD0005-

      Electronic Promass/Cubemass 100

      Main electronic module

  • 39
    • Nr 39 Order code 71185788

      Kit T-DAT, 100/300/400/500/500 digital

      Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Promag 400(C). (C) = generation index C.

  • 50
    • Nr 50 Order code XPD0023-

      Display module, 4-wire, 100

      Usage: Promag 100, Promass 100, Prosonic Flow E 100.

  • 21
    • Nr 21 Order code 71185789

      Kit cover, compact, Alu

      Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: Cover Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.

    • Nr 21 Order code 71185792

      Kit cover, compact, stainless 1.4404

      Usage: Promass 100. Consists of: Cover stainless 1.4404. Gasket EPDM for cover.

    • Nr 21 Order code 71185794

      Kit cover,ultra compact,stainless 1.4404

      Usage: Promass 100, Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4404, gasket EPDM for cover.

  • 20
    • Nr 20 Order code 71266334

      Kit cover, sight glass, compact, Alu

      Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat. Consists of: Cover with sight glass Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.

    • Nr 20 Order code 71266336

      Kit cover, sight glass, compact, 1.4404

      Usage: Promass 100. Consists of: Cover with sight glass stainless 1.4404. Gasket EPDM for cover.

    • Nr 20 Order code 71266338

      Kit cover,sight glass,ultra comp.,1.4404

      Usage: Promass 100. Consists of: Cover with sight glass stainless 1.4404. Gasket EPDM for cover.

  • 70
    • Nr 70 Order code 71185795

      Kit housing gaskets, compact, Alu

      Usage: Promass 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: O-Ring 113,90 x 3,53 NBR for cover. Gasket EPDM for housing/sensor.

    • Nr 70 Order code 71185797

      Kit housing gaskets, compact, stainless

      Usage: Promass 100. Consists of: Gasket EPDM for cover. Gasket EPDM for housing/sensor.

    • Nr 70 Order code 71185799

      Kit hous.gaskets,ultra compact,stainless

      Usage: Promass 100, Promass 500 digital, sensor connection housing. Consists of: gasket EPDM for cover, gasket EPDM for housing/sensor.

  • 15
    • Nr 15 Order code 50098036

      Kit 10 cable glands M20x1.5 Ex

    • Nr 15 Order code 71069285

      Kit 2 cable glands M20x1.5 INOX Ex

    • Nr 15 Order code 50098041

      Kit 10 ext. M20x1.5/G 1/2" (plug PVC)

    • Nr 15 Order code 71185802

      Kit 2 cable glands G1/2" INOX Ex

      Consists of: 2 x Extension M20x1,5/G1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug G1/2".

    • Nr 15 Order code 50098042

      Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)

    • Nr 15 Order code 71185800

      Kit 2 cable glands NPT1/2" INOX Ex

      Consists of: 2 x Extension M20x1,5/NPT1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug NPT1/2".

  • 12
    • Nr 12 Order code 71276494

      Kit securing clamp, screw

      Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensor housing: Promag 400(C), (C) = generation index C, Promag/Promass 500, Promag/Promass 500 digital. Consists of: cover clamp, screw M4x16.

    • Order code XPRFID-

      Spare RFID TAG