Radar measurement
Micropilot FMR530

Micropilot FMR530 ©Endress+Hauser

Time-of-Flight measuring principle

For custody transfer and inventory control applications with NMi- and PTB-approvals

The Micropilot FMR530 is used for highly accurate non-contact level measurement in storage tanks and can be applied in custody transfer applications. It meets the relevant requirements according to OIML R85 and API 3.1B. The FMR530 free space radar offers cost-effective and simple installation via 4-wire cable with HART and
24 V DC intrinsically safe power supply.

  • Fördelar

    • 0.5mm accuracy (2σ value)

    • National approvals (NMi, PTB) for custody transfer

    • Applicable as stand-alone system or integrated tank gauging systems via the Tank Side Monitor NRF590

    • Easy on-site operation via menu-driven alphanumeric display

    • Easy commissioning...

  • Applikationsområde

    With horn antenna suitable for free space applications (up to 25m) that disallow the use of a parabolic antenna due to tank/nozzle geometry.

    • Process connection: Flange

    • Temperature: -40 to +200°C (-40 to +392°F)

    • Pressure: -1 to +64bar (-14.5 to +928psi)

    • ...

Funktioner och specifikationer

Tillbaka

Details

  • Mätprincip

    Level radar

  • Supply / Communication

    4-wire (HART)

  • Frequency

    C-band (~6 GHz)

  • Accuracy

    +/- 1 mm

  • Ambient temperature

    Standard:
    -40 °C ... 80 °C
    (-40 °F ... 176 °F)
    For calibration to regulatory standards:
    -25 °C ... 60 °C
    (-13 °F ... 131 °F)

  • Process temperature

    -40 °C ... 200 °C
    (-40 °F ... 392 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum ... 64 bar
    (Vacuum ... 580 psi)

  • Main wetted parts

    316Ti

  • Process connection

    DN150 ... DN250 /3" ... 10"

  • Application

  • Max. measurement distance

    25 m (82ft)

  • https://portal.endress.com/picpool/sft/prodcont/technicalinfo/Radar_Mediengruppe_en.jpg https://portal.endress.com/picpool/sft/prodcont/technicalinfo/Radar_not_selected_FMR530.jpg
  • Communication

    4 ... 20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, NEPSI

  • Safety approvals

    Overfill prevention WHG

  • Marine approval

    GL/ ABS

  • Application limits

    Maximum measuring range is dependent on the tank form and/or application


    Free space and many baffles

    FMR540

Dokumentation / manualer / programvara

Tillbehör / reservdelar

Nr
Order code
Specification
  • 25
    • Nr 25 Order code 518710-0020

      Cover T3/T12 Alu, coated, gasket

      Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231,FMR240/FMR244/ FMR245, FMR250, FMR530/FMR531/FMR532/ FMR533, FMR540, FMU40/FMU41/FMU42.

  • 20
    • Nr 20 Order code 52005936

      Cover F12/T12 Alu, window, gasket

      Material: aluminium. Usage: VU331, housing F12/T12, Micropilot M/S, Prosonic M, Levelflex M.

  • 11
    • Nr 11 Order code 52005643

      Hood housing T12

      Cable compartment, electronics side. Usage: Micropilot M/S, Prosonic M, Levelflex M.

  • 35
    • Nr 35 Order code 52005586

      Terminal module 5-pole, FMR53x

      Usage: housing T12, FMR530/FMR531/FMR532/FMR533, till CW20/2009.

    • Nr 35 Order code 71020581

      Terminal module 5-pole, Ex i, FMR53x/540

      Usage: FMR530/FMR532/FMR533, FMR540.

    • Order code 71092209

      O-ring 113.9x3.63 EPDM, 5 pieces

      Usage: cover T12/F12/F23.

  • 40
    • Nr 40 Order code 52026443

      Display VU331, version 2

      Alphanumeric display, 4-line. Usage: FMR530/532/533, FMR540, FMU40/41/42/43/44.

  • 30
    • Nr 30 Order code XPF0028-

      Electronics FMR530, Ex, HART, HF Modul

      Usage: FMR530.

  • 55
    • Nr 55 Order code 52021131

      Horn FMRx3x, DN80/3", 316/316L

      Allen screws + spring washers. Usage: FMR230, FMR530. Nordlock washer.

    • Nr 55 Order code 52021132

      Horn FMRx3x, DN100/4", 316/316L

      Allen screws + spring washers. Usage: FMR230, FMR530. Nordlock washer.

    • Nr 55 Order code 52021133

      Horn FMRx3x, DN150/6", 316/316L

      Allen screws + spring washers. Usage: FMR230, FMR530. Nordlock washer.

    • Nr 55 Order code 52021134

      Horn FMRx3x, DN200/8", 316/316L

      Allen screws + spring washers. Usage: FMR230, FMR530. Nordlock washer.

    • Nr 55 Order code 52021135

      Horn FMRx3x, DN250/10", 316/316L

      Allen screws + spring washers. Usage: FMR230, FMR530. Nordlock washer.

  • 65
    • Nr 65 Order code 52005628

      Sealing kit FMR5xx

      Consists of: 5x O-ring 49.21x3.53 EPDM. 5x O-ring 113.9x3.63 EPDM. 5x O-ring 72.0x3.0 EPDM.

    • Order code 52007646

      Tool for unplugging the antenna cable

      Usage: Micropilot M/Micropilot S.

    • Order code 71006590

      HF-test cable 6GHz

      Coax cable. Usage: FMR230/FMR231, FMR530/FMR531/FMR532/FMR533, FMR540. Dummy antenna.

    • Order code 71007843

      ToF Adapter FXA291

      Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.

    • Order code 71067434

      Modification name plate, non Ex

      Blank. To fill in the new order code when a non Ex instrument has been modified. Usage: FMB50/FMB51/FMB52, FMR230/FMR231, FMR240/FMR244/FMR245, FMR250,FMR530/FMR532,FTL50/FTL50H/FTL51/ FTL51C/FTL51H, FTL70/FTL71, FTL80/FTL81/ FTL85, NMR81, PMC51, PMC71, PMP51/PMP55.

    • Order code 52028063

      HF-test cable 6GHz + resistor

      Coax cable. Termination resistor / connection piece. Usage: FMR530/FMR532/FMR533, FMR540. Dummy antenna.