En överblick över specifikationer
-
Accuracy
+/- 2mm + 0.17% of measured distance
Applikationsområde
Prosonic FMU90 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk solids. Also the flow measurement in open channels and weirs is possible as the simultaneous measurement of level and flow in a storm water overflow basin with only 1 sensor. Up to 6 relays for tendency alarm, flow pulse output or backwater/sludge alarm, 1 or 2 channel version.
Level measurement of fluids and bulk materials with 1 or 2 sensors for measuring of up to 45m (148ft) and level limit detection. Pump control, rake control and as option: additional pump control function.
Calculations: Average, difference, sum
Application flow: Flow measurement in open channels and weirs with 1 or 2 sensors
Flow measurement with back water or sludge detection
Up to 3 totalizers and 3 counters
Counting or time pulse output for control of external units
Fördelar
Simple, menu-guided operation with 6-line plain text display, 15 languages selectable
Envelope curves on the display for quick and simple diagnosis
Easy operation, diagnosis and measuring point documentation with the supplied "FieldCare" operating program
Time-of-Flight correction via integrated or external temperature sensors
Linearisation (up to 32 points, freely configurable) for the most common flumes and weirs
pre-programmed and selectableOnline calculation of the flume-/weir-flows via integrated flow curves
Automatic detection of the sensors FDU9x
Videor
Xpert urvalet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
Föregångare
-
-
Teknisk information (TI)
Prosonic S FMU90
Engelsk version - 05/2021
Ultrasonic measuring technology
EN SV 31/05/202124/08/202021/03/201712/08/201622/03/2013Språk:
Engelska
Version:
31/05/2021
Filstorlek:
1.3 MB
Filnamn:
TI00397FEN_1921.pdf
-
-
-
Användarinstruktion (BA)
Prosonic S FMU90
Engelsk version - 04/2012
Ultrasonic Transmitter
EN SV 02/04/201223/07/200914/01/200805/05/200702/03/2007Språk:
Engelska
Version:
02/04/2012
Filstorlek:
3 MB
Filnamn:
BA00290FEN_1312.pdf
-
-
-
Teknisk information (TI)
Khafagi-Venturi QV302...QV316
Flow measurement
EN SV 18/05/2022Språk:
Engelska
Version:
18/05/2022
Filstorlek:
496.3 KB
Filnamn:
TI01681FEN_0122-00.pdf
-
-
-
Teknisk information (TI)
Prosonic S FMU90
Ultrasonic measuring technology
EN SV 31/05/202124/08/202021/03/201712/08/201622/03/2013Språk:
Engelska
Version:
31/05/2021
Filstorlek:
1.3 MB
Filnamn:
TI00397FEN_1921.pdf
-
-
-
Teknisk information (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN SV 25/03/202415/09/202328/10/202130/07/202119/06/2020Språk:
Engelska
Version:
25/03/2024
Filstorlek:
1.1 MB
Filnamn:
TI00426FEN_2524.pdf
-
-
-
Användarinstruktion (BA)
Prosonic S FMU90 PROFIBUS DP
Ultrasonic measuring technology
Level measurement
1 or 2 sensorsEN SV 31/05/202117/08/202002/04/201223/07/200906/04/2009Språk:
Engelska
Version:
31/05/2021
Filstorlek:
3.2 MB
Filnamn:
BA00292FEN_1621.pdf
-
-
-
Användarinstruktion (BA)
Prosonic S FMU90 HART
Ultrasonic measuring technology
Level measurement
1 or 2 sensorsEN SV 31/05/202117/08/202021/03/201702/04/201223/07/2009Språk:
Engelska
Version:
31/05/2021
Filstorlek:
3.3 MB
Filnamn:
BA00288FEN_1621.pdf
-
-
-
Användarinstruktion (BA)
Prosonic S FMU90 HART
Ultrasonic measuring technology
Flow measurement
1 or 2 sensorsEN SV 31/05/202117/08/202002/04/201223/07/200906/04/2009Språk:
Engelska
Version:
31/05/2021
Filstorlek:
3.1 MB
Filnamn:
BA00289FEN_1621.pdf
-
-
-
Användarinstruktion (BA)
Prosonic S FMU90
Ultrasonic Transmitter
EN SV 02/04/201223/07/200914/01/200805/05/200702/03/2007Språk:
Engelska
Version:
02/04/2012
Filstorlek:
3 MB
Filnamn:
BA00290FEN_1312.pdf
-
-
-
Användarinstruktion (BA)
Prosonic S FMU90 PROFIBUS DP
Ultrasonic measuring technology
Flow measurement
1 or 2 sensorsEN SV 31/05/202117/08/202002/04/201223/07/200906/04/2009Språk:
Engelska
Version:
31/05/2021
Filstorlek:
3.1 MB
Filnamn:
BA00293FEN_1621.pdf
-
-
-
Användarinstruktion (BA)
Prosonic S FMU90
Slot-Index Lists for PROFIBUS DP
EN SV 02/04/201230/04/200726/06/2006Språk:
Engelska
Version:
02/04/2012
Filstorlek:
6.2 MB
Filnamn:
BA00333FEN_1312.pdf
-
-
-
Enhetsparameter (GP)
Prosonic S FMU90
Level measurement
Flow measurement over open channelsEN SV 31/08/2020Språk:
Engelska
Version:
31/08/2020
Filstorlek:
1.7 MB
Filnamn:
GP01151FEN_0120.pdf
-
-
-
Kortfattad instruktion (KA)
Prosonic S FMU90 PROFIBUS DP
Mätteknik med ultraljud
Flödesmätning
En eller två sensorerEN SV 11/07/202231/05/202124/08/202017/05/201915/02/2017Språk:
Svenska
Version:
11/07/2022
Filstorlek:
1.2 MB
Filnamn:
KA01068FSV_0722-00.pdf
-
-
-
Kortfattad instruktion (KA)
Prosonic S FMU90 PROFIBUS DP
Mätteknik med ultraljud
Nivåmätning
En eller två sensorerEN SV 11/07/202231/05/202124/08/202015/02/201728/06/2016Språk:
Svenska
Version:
11/07/2022
Filstorlek:
1.3 MB
Filnamn:
KA01067FSV_0622-00.pdf
-
-
-
Kortfattad instruktion (KA)
Prosonic S FMU90 Quick Setup
Transmitter in housing for field or top-hat rail mounting for the
ultrasonic sensors FDU91/91F/92/93/95/96EN SV 31/01/2006Språk:
Engelska
Version:
31/01/2006
Filstorlek:
64.9 KB
Filnamn:
KA270fa2.pdf
-
-
-
Kortfattad instruktion (KA)
Adapter plate for Prosonic S FMU90/FMU95
Mounting Instructions
EN SV 07/01/2008Språk:
Engelska
Version:
07/01/2008
Filstorlek:
145.3 KB
Filnamn:
KA256FA2_0905.pdf
-
-
-
Kortfattad instruktion (KA)
Mounting plate for Prosonic S FMU90, FMU95 with field housing
Mounting plate for Prosonic S FMU90, FMU95 with field housing
EN SV 19/05/2021Språk:
Engelska
Version:
19/05/2021
Filstorlek:
321 KB
Filnamn:
KA00646FA2_0507.pdf
-
-
-
Kortfattad instruktion (KA)
Exchange of DIN rail housing for Prosonic S FMU90, FMU95
Exchange of DIN rail housing for Prosonic S FMU90, FMU95
EN SV 19/05/2021Språk:
Engelska
Version:
19/05/2021
Filstorlek:
751.7 KB
Filnamn:
KA00644FA2_0507.pdf
-
-
-
Kortfattad instruktion (KA)
Remote display and operating module for Prosonic S FMU90, FMU95
Remote display and operating module for Prosonic S FMU90, FMU95
EN SV 20/05/2021Språk:
Engelska
Version:
20/05/2021
Filstorlek:
192.8 KB
Filnamn:
KA00648FA2_0107.pdf
-
-
-
Kortfattad instruktion (KA)
Prosonic S FMU90 HART
Mätteknik med ultraljud
Flödesmätning
En eller två sensorerEN SV 11/07/202231/05/202124/08/202003/05/201715/02/2017Språk:
Svenska
Version:
11/07/2022
Filstorlek:
1.2 MB
Filnamn:
KA01066FSV_0722-00.pdf
-
-
-
Kortfattad instruktion (KA)
Prosonic S FMU90 HART
Mätteknik med ultraljud
Nivåmätning
En eller tvåsensorerEN SV 11/07/202231/05/202124/08/202016/02/201715/02/2017Språk:
Svenska
Version:
11/07/2022
Filstorlek:
1.2 MB
Filnamn:
KA01065FSV_0722-00.pdf
-
-
-
Kortfattad instruktion (KA)
Exchange of electronic modules on Prosonic S
Exchange of electronic modules on Prosonic S
EN SV 24/04/2012Språk:
Engelska
Version:
24/04/2012
Filstorlek:
1009.4 KB
Filnamn:
KA00642FA2-1007.pdf
-