Absolute and
gauge pressure
Cerabar PMC51

Digital pressure transmitter with oil-free ceramic sensor for measurement in gases or liquids

  • Cerabar PMC51 aluminum housing ©Endress+Hauser
  • Cerabar PMC51 hygienic housing ©Endress+Hauser
  • Cerabar PMC51 hygienic housing ©Endress+Hauser
  • Cerabar PMC51 hygienic housing ©Endress+Hauser
  • Pressure measuring principle

  • Cerabar PMC51 beauty shot ©Endress+Hauser

The Cerabar PMC51 digital pressure transmitter with capacitive, oil-free ceramic measuring cell is typically used in process and hygienic applications for pressure, level, volume or mass measurement in liquids and gases. It guarantees high degree of system safety thanks to vacuum-proof ceramic membrane with integrated breakage detection. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2 according to IEC 61508 / IEC 61511.

Fördelar

  • Best fit for vacuum applications and applications with corrosive and abrasive media

  • Process safety through membrane breakage detection

  • Overload-resistant high purity ceramic sensor (99.9% Al2O3)

  • Condensation resistant also for hygienic applications

  • Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus

  • Process pressure up to SIL2, certified to IEC 61508 and IEC 61511

  • Modular concept for easy replacement of display or electronics

Applikationsområde

Single chamber aluminum or stainless steel (316L) housing.

  • Process connections: Threads, flanges or hygienic connections

  • Process temperature: -40 to +130°C (-40 to +266°F), 150°C (302°F) for 1h

  • Measuring ranges: -1/0 up to +40bar (-15/0 to +600psi)

  • Accuracy: ±0.15%, "Platinum" ±0.075%

  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals

Funktioner och specifikationer

Dokumentation/manualer/programvara

Tillbehör/reservdelar

Föregångare / Ersättare

Föregångare: Cerabar M PMC41, Cerabar M PMC45

Kontakt

Endress+Hauser AB
Box 1486 171 28 Solna , Sverige
Tel.: +46 (0)8 555 116 00
Fax: +46 (0)8 555 116 55
Skicka e-post www.se.endress.com

Relaterade nyheter

Online-verktyg

Den här webbplatsen använder cookies. Genom att fortsätta använda webbplatsen godkänner du att vi använder cookies. Läs mer här Stäng