Vibronic
Point level detection
Nivotester FTL325P

Switching unit with intrinsically safe signal circuit for connection to Liquiphant or Soliphant

  • Nivotester FTL325P ©Endress+Hauser
  • Nivotester FTL325P ©Endress+Hauser

The switching unit FTL325P is used for point level detection in liquid tanks and bulk material silos, also in hazardous explosion areas. Also suitable for liquid detection in pipes for dry running protection for pumps and overfill prevention for tanks with combustible or non-combustible liquids harmful to water. Up to 3 measuring devices for two-point control and point level detection. Functional safety up to SIL3 in accordance to IEC 61508 using Liquiphant with electronic insert FEL57.

Fördelar

  • Nivotester FTL325P for connecting one, two or three measuring cells (1-, 2- or 3-channel devices)

  • Intrinsically safe signal circuits Ex ia for use of measuring sensor in explosion hazardous areas

  • Functional safety up to SIL2 through line monitoring. Simplified proof testing to WHG/SIL by pressing push-button

  • DIN Rail housing for simple series installation on standard rails in switch cabinet

  • Simple wiring using pluggable terminal blocks

  • Inputs are galvanically isolated from each other, from the mains and from the outputs

Applikationsområde

Switching unit with intrinsically safe signal circuit for connection to Liquiphant or Soliphant.

  • Ambient temperature: -20 to +70°C (-4 to +158°F)

  • International explosion protection certificates, overfill prevention WHG, marine approvals

Funktioner och specifikationer

Dokumentation/manualer/programvara

Tillbehör/reservdelar

Föregångare / Ersättare

Föregångare: FTL320, Nivotester FTL375P