Endress+Hauser-koncernen

Mediacenter

Event

En karriär hos Endress+Hauser

Support

Online Shop

Ange dina personliga inloggningsuppgifter för att komma till online-shoppen och lägg din order när som helst, dygnet runt. Här hittar du också prisuppgifter och leveranstider och kan skicka offertförfrågningar.

Online Shop

E-direct Shop

E-direct - Beställ förkonfigurerade fältinstrument och systemkomponenter snabbt och enkelt online.

E-direct Shop

iTEMP TMT125
DIN rail temperature transmitter

Transformation of sensor signals into standardized digital output signals for all industries

  • ©Endress+Hauser
  • ©Endress+Hauser
  • ©Endress+Hauser
  • ©Endress+Hauser

Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers digital converted signals from RTD and TC sensors, it also transfers resistance and voltage signals using FOUNDATION Fieldbus™ communication. High measurement point availability by means of sensor monitoring functions and device hardware fault recognition. Optionally, installation on DIN rail according to IEC 60715 or in a field housing.

Fördelar

  • Universal temperature transmitter for up to 8 input signals

  • Sensor monitoring: cable open circuit, short-circuit and wiring error

  • Device hardware fault recognition for reliable operation and easy maintenance

  • Galvanic isolation between fieldbus and sensor inputs and between the input channels

  • Ex-Certification: FM IS, NI; ATEX Ex ia, Ex na for intrinsically safe installation in zone 1 and as associated apparatus in zone 2

  • Independent installation of connected temperature sensors in zone 0

  • Transducer block 'concentrator' and Multiple Analog Input Block (MAI) allow for effective and fast configuration of the relevant parameters

Applikationsområde

  • Temperature transmitter with 8 input channels and FOUNDATION Fieldbus™ protocol for converting various input signals into digital output signals

  • Input: Resistance thermometers (RTD), thermocouples (TC) resistance transmitters (Ω), voltage transmitters (mV)

  • DIN rail mounting as per IEC 60715 and with aluminum housing for field operation

Funktioner och specifikationer

Dokumentation/manualer/programvara

Tillbehör/reservdelar

Kontakt

Endress+Hauser AB
Box 1486 171 28 Solna , Sverige
Tel.: +46 (0)8 555 116 00
Fax: +46 (0)8 555 116 55
Skicka e-post www.se.endress.com

Relaterade nyheter

Online-verktyg

Den här webbplatsen använder cookies. Genom att fortsätta använda webbplatsen godkänner du att vi använder cookies. Läs mer här Stäng