En överblick över specifikationer
-
Max. measurement error
Volume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to 200
±2% o.r. above DN200 -
Measuring range
0.3 to 10 m/s (1 to 33 ft/s)
-
Medium temperature range
-20 to +80°C (-4 to +176 °F)
0 to +130°C (32 to +265 °F) option -
Max. process pressure
N/A
-
Wetted materials
Clamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304
Applikationsområde
The Prosonic Flow W clamp-on sensor is specially designed for water and wastewater applications. Combined with the cost-effective Prosonic Flow 91 transmitter with push buttons, Prosonic Flow 91W is ideally suited for flow monitoring in the water industry.
The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
Clamp-on flow measurement of process water, salt water, deminerialized water, drinking & wastewater.
Device properties:
Medium temperature: –20 to +80 °C (-4 to +176 °F)
Degree of protection IP68 (Type 6P enclosure) for pipes under water
Shock and vibration resistance according to IEC 68-2-6
Aluminium field transmitter housing
2-line display with push buttons
HART
Fördelar
Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 2000)
Long-term stable signal - maintenance-free permanent mounting from outside with coupling pads
Process transparency – diagnostic capability
Economical transmitter – designed for easy applications
Fast and reliable commissioning – Quick Setup menu for installation
Automatic recovery of data for servicing
Videor
Föregångare
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
-
-
Teknisk information (TI)
Proline Prosonic 91W Technical Information
Engelsk version - 12/2023
Ultrasonic Flow Measuring System Flowrate measurement for standard applications with drinking water and process water.
EN SV 06/12/202319/08/201101/02/2010Språk:
Engelska
Version:
06/12/2023
Filstorlek:
1.8 MB
Filnamn:
TI00105DEN_1423.pdf
-
-
-
Användarinstruktion (BA)
Prosonic Flow 91 Operating Instructions
Engelsk version - 12/2023
Ultrasonic Flow Measuring System Flow rate measuring for standard applications with drinking water, wastewater and process water (incl. Description of Device Functions)
EN SV 06/12/202319/08/201101/02/201001/04/2006Språk:
Engelska
Version:
06/12/2023
Filstorlek:
5.4 MB
Filnamn:
BA00100DEN_1423.pdf
-
-
-
Teknisk information (TI)
Proline Prosonic 91W Technical Information
Ultrasonic Flow Measuring System
Flowrate measurement for standard applications with
drinking water and process water.EN SV 06/12/202319/08/201101/02/2010Språk:
Engelska
Version:
06/12/2023
Filstorlek:
1.8 MB
Filnamn:
TI00105DEN_1423.pdf
-
-
-
Teknisk information (TI)
Prosonic Flow 90U, 90W, 91W, 93C, 93U, 93W Technical Information (SI units)
Ultrasonic Flow Measuring System
Volume Flow Measurement for Standard Applications with Water, Wastewater
and Process WaterEN SV 01/04/200601/05/200515/10/200301/12/2002Språk:
Engelska
Version:
01/04/2006
Filstorlek:
1.4 MB
Filnamn:
TI057DEN.pdf
-
-
-
Användarinstruktion (BA)
Prosonic Flow 91 Operating Instructions
Ultrasonic Flow Measuring System
Flow rate measuring for
standard applications with
drinking water, wastewater and
process water
(incl. Description of Device Functions)EN SV 06/12/202319/08/201101/02/201001/04/2006Språk:
Engelska
Version:
06/12/2023
Filstorlek:
5.4 MB
Filnamn:
BA00100DEN_1423.pdf
-
-
-
Kortfattad instruktion (KA)
Proline Prosonic Flow 90, 91, 93 Sonderdokumentation / Special Documentation
Montageanleitung für die Verbindung Sensoren / Messumformer bei
Verwendung von flexiblen Kabelschutzrohren
Mounting instruc
tions for the sensor / transmitter connection using flxible conduitEN SV 01/11/2006Språk:
Engelska
Version:
01/11/2006
Filstorlek:
228.6 KB
Filnamn:
KA015Da2.pdf
-
-
-
Kortfattad instruktion (KA)
Proline Prosonic Flow 91W Brief Operating Instructions
Ultrasonic flow measuring system
EN SV 13/02/201219/08/201126/04/2010Språk:
Svenska
Version:
13/02/2012
Filstorlek:
2.5 MB
Filnamn:
KA00049DSV_1412.pdf
-
-
-
Installationsanvisningar (EA)
Replacing T-DAT Installation Instructions
Promag 23, 53, 55, Promass 83, 84, 8WF, 8ME, Cubemass DCI 8CN, CNGmass
DCI 8DF, Prosonic Flow 91, 93, t-mass 65EN SV 15/11/201821/11/2011Språk:
Engelska
Version:
15/11/2018
Filstorlek:
481.6 KB
Filnamn:
EA00072DA2_1418.pdf
-
-
-
Installationsanvisningar (EA)
Safety Instructions for Spare Parts Installation Instructions
Flowmeter
EN SV 01/03/201828/11/201325/04/2013Språk:
Engelska
Version:
01/03/2018
Filstorlek:
139.5 KB
Filnamn:
EA01051DA2_0318.pdf
-
-
-
Installationsanvisningar (EA)
Replacing cover and O-ring Installation Instructions
romag 10, 23, 50, 51, 53, 55, 400, 800, Promass 40, 80, 83, 84, 8ME,
CNGmass 8FF, LPGmass 8FE, Cubemass 8CM, Prosonic Flow 90, 91,9
2, 93, t-mass 65, Prowirl 72, 73EN SV 01/10/201828/06/2012Språk:
Engelska
Version:
01/10/2018
Filstorlek:
520.1 KB
Filnamn:
EA00098DA2_1518.pdf
-
-
-
Installationsanvisningar (EA)
Replacing transmitter parts Installation Instructions
Promag 10, Prosonic Flow 91 W
EN SV 01/04/201917/11/2011Språk:
Engelska
Version:
01/04/2019
Filstorlek:
558.9 KB
Filnamn:
EA00040DA2_1419.pdf
-
-
-
Installationsanvisningar (EA)
EA Permanent Coupling Pad
Prosonic Flow 91W, 93P, W 400, P 500
EN SV 01/03/202415/12/202101/08/202116/09/2019Språk:
Engelska
Version:
01/03/2024
Filstorlek:
609.4 KB
Filnamn:
EA01256DA2_0423-00.pdf
-